Council archive · source document
07/2482 - MCU - Multiple Housing Type 4 Conventional (3 Units) [As Published] · 132007.2482
Town Planning Assessment Report - 5 Solway Drive, Sunshine Beach Heron Street, Peregian Beach, have a maximum gross floor area of 1200m?. O10 For the Detached Housing Zone and Semi-attached Housing Zone-soft landscaping is provided and retained over a minimum of 20% of the site area. O71 For the Neighbourhood Centre Zone the maximum plot ratio is as tollows- Q) 0.8:1 for site areas up to and including 2000m?; and b) 0:3:1 for that area of a sife in excess of 2,000m?. The proposed development complies with this requirement. Flooding and drainage * O12 Buildings and other works are designed and sited to- Q) provide flood free access to premises and flood free habitable areas; b) allow only minor, short term and infrequent flooding of non-habitable areas; c) ensure drainage does not adversely impact upon other premises; and d) ensure filling or excavation does not adversely impact upon other premises by- i. causing ponding on the site or nearby land; il, increasing flooding, which adversely affects the safety or use of any land upstream and downstream; and ill. adversely affecting the flow of water in any overland flow path, $12.1 Floor levels for habitable rooms are- a) for areas where minimum floor levels are available-not less than the specified level: : b) for areas where flood modelling Is availatle-a minimum of 500mm above the modelled flood level; and c) for areas where flood modelling is not available, a minimum of 500mm above the highest known flood level; AND $12.2 Where Council infrastructure is available- Q) any drainage (for buildings and lang) flows to that infrastructure: and b) the infrastructure has the capacity to accept any additional loading, The proposed development will build upon the existing structure. {t is not considered that the subject site is subject to flooding. The proposal complies with this requirement. Roof form 013 Roof forms- a) contribute positively to the local skyline; b) complement the beachside character of the locality; c) use soft and articulated pitched or curved roof forms; d) avoid low pitched (eg. less than 5 degrees) or box profiles/parapets; and &) do not create opportunities for residents to overlook the private open space areas of neighbouring properties. $13.1 The main roof of the building has a roof pitch no less than 5 degrees and has roof overhangs a minimum of 600mm wide; AND $13.2 Buildings and structures do not include roof top terraces. The proposed = additional level incorporates a roof profile which minutes the lower-level and is compatible with surrounding development. The attached elevations outline the intended roof form and is considered to comply with the specific outcome. The proposal complies with this outcome and probable solution, Sloping sites $14.1 Buildings and associated accessways are not constructed on land with a slope greater than 25% Not applicable to the development application, Page 15 of 22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2482 - MCU - Multiple Housing Type 4 Conventional (3 Units) [As Published]Related documentApplication case desk ↗
About this file
- File size
- 8.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.