Council archive · source document
07/2482 - MCU - Multiple Housing Type 4 Conventional (3 Units) [As Published] · 132007.2482
Town Planning Assessment Report - 5 Solway Drive, Sunshine Beach airspace of the Sunshine Coast Airport. 4.3m per second. (See Map MA2 below) 6.5 Specific outcomes and probable solutions for the Semi-attached Housing zone specific outcomes Probable solutions v/* /- Response 7.18 Effects of use Not applicable to the development application 7.19 built form Streetscape character 035 Buildings and other structures- a) contribute positively to the streetscape character by addressing the street and adding visual interest through stepping the front facades; b) have a bulk and architectural scale that does not dominate the streetscape or detract from the visual amenity of adjoining properties; Cc) present as a small building of a domestic scale within a landscaped setting; and d) present well articulated facades where garages or carports are not the dominant visual element when viewed from the street; Figure 7.2-Use of design features to reduce building bulk Figure 7.3-Adding visual interest to building facades x opnag|a Lie Hy THE BUILDING ABOVE IS INCONSISTENT WITH THE OUTCOMES AS THERE IS NO ARTICULATION OR VISUAL INTEREST. THE BUILDING BELOW IS CONSISTENT AS IT {SWELL ARTICULATED, CREATES DIFFERENT SHADOW LINES AND IS VISUALLY INTERESTING. 535.1 The main entrance of the building faces and Is recognisable from the street: AND $35.2 Buildings and other structures are designed to- a) have maximum wall tength of 15m and each external wall plane incorporates at least one design element to add visual interest and amenity (such as windows, pergolas, sun shading devices, balconies or a change of building material). (see Figure 7.2, Figure 7.3 and Figure 7.4); b) vary and break up the roof form through gables or different pitches to add visual interest and define the individual dwelling units (see Figure 7.2, Figure 7.3 and Figure 7.4); c) provide individual segmented balconies for each dwelling unit to reduce dominant horizontat banding and to provide private open space for each tenancy (see Figure 7.2, Figue 7.3 and Figure 7.4); d) break up building facades by incorporating different but complimentary textures and building materials; and e) visually break up the bulk of the building by integrating tall ptant species in front of and to the side of bulldings; Figure 7.4-Articulation and orientation for privacy The location the existing building is approximately 13 metres from the Solway Dr frontage. The proposed second-storey addition will be located directly above the existing units. The orientation of the extension will be towards the northeast, which is towards the street frontage. The attached plans and elevations clearly demonstrate that the proposed development includes a number of articulated walls and design elements to ensure that the new development is not inconsistent with the existing development and results in a sympathetic an_ interesting addition to the building, Page 18 of 22
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2482 - MCU - Multiple Housing Type 4 Conventional (3 Units) [As Published]Related documentApplication case desk ↗
About this file
- File size
- 8.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.