Original source · versioned page text
Noise Report
Medicentre 2 Pty Ltd ATF Medicentre Properties No 2 Trust Environmental Noise Level Impact Assessment for Proposed Medical Centre, 45 Maple Street, Cooroy Page 5 of 20 CRITERIA Measurements and Calculations All noise level measurements were conducted in accordance with the following: general requirements of the Queensland environmental protection legislation; Environmental Protection (Noise) Policy 2019; Noosa Council’s applicable planning criteria; Noise Measurement Manual, Queensland Government – Environmental Protection Agency, Version 4, August 2013; and Australian Standard AS 1055-2018, Acoustics – Description and Measurement of Environmental Noise. Noise Limits Noise from the proposed medical centre has the potential to noise impact the adjoining residential uses. The Noosa Plan does not contain any specific noise limit criteria relative to this proposed development and, therefore, the requirements of the Queensland Environmental Protection legislation has been relied upon. In accordance with the Environmental Protection Act 1994 Default Noise Standards the noise limits for air-conditioning units (same noise limits assumed for any exhaust fans as well) are: daytime (0700 to 1800 hours): background (LA90) + 5 dB(A); evening (1800 to 2200 hours): background (LA90) + 5 dB(A); night-time (2200 to 0700 hours): background (LA90) + 3 dB(A). In accordance with Schedule 1 of the Environmental Protection (Noise) Policy 2019, the Acoustic Quality Objectives criteria are as follows: Acoustic quality objectives, daytime and evening, external to dwelling: o 50 dB(A) LAeq,adj,1H; o 55 dB(A) LA10,adj,1H; and o 65 dB(A) LA1,adj,1H; Acoustic quality objectives, daytime and evening, inside dwelling: o 35 dB(A) LAeq,adj,1H; o 40 dB(A) LA10,adj,1H; and o 45 dB(A) LA1,adj,1H; Acoustic quality objectives, night-time, inside dwelling: o 30 dB(A) LAeq,adj,1H; o 35 dB(A) LA10,adj,1H; and o 40 dB(A) LA1,adj,1H; For the night-time period the internal noise criteria needs to be converted to be equivalent to outside the closest residential. Allowing a 5 dB(A) noise level reduction from outside to inside (based on all of the windows fully open and in accordance with the Queensland Environmental Protection Agency Ecoaccess Guideline Planning for Noise Control) the internal criteria would be equivalent to the following levels external to the dwelling: David Moore & Associates Pty Ltd Our reference: R20018/D3464/Rev.0/9.03.20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (Noise Report.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.