Council archive · source document
MCU18-0135 - Approved Plans · MCU18/0135
Plans and drawings: the text below has words only, no drawings.
Original PDF page 3, section 1. The text section number identifies this passage in the reader.
Window and Door Legend Notes General Notes Engineering Notes
All window and door sizes and loca on to be confirmed on site by builder/client prior to construc on Refer to Engineers details for:
F Fixed Glass Window SW Glass Sliding Window CS Cavity Sliding Door Ducted air condi oning (Reverse Cycle) to manufactures details Do not scale dimensions. Removable door to WC.
All exposed mullions to have coverplates to match window frames Check and verify all dimensions prior to commencement. Foo ngs, Slab, Tiedown, Bracing, Framing
DH Double Hung Window BJG Site Meas. Bu Joint Glass FW Front of Wall Sliding Door Schedule, Floor Construc on, Roof framing and
L Glass Louvre Window RFG Raked Fixed Glass Window SD Glass Sliding Door Frameless mirrors to all bathrooms These plans to be read in conjunc on with engineers report
Square set ceilings throughout - refer builders details All windows to be verified against floor plans and eleva ons by contractor. Truss details, Wind Category, Pool, Retaining Walls
ML Metal Louvre Window OBS Obscure Glazing BD Bi-fold Door
TL Timber Louvre Window M Mullion + Coverplate MSD Mul -Track Glass Sliding Door Can levered trusses throughout - refer engineers details Discrepancies are to be reported to the designer prior to commencement. Plumbing and drainage
A Awning Window CP Coverplate Glass handrails to be semi-frameless. All work to comply with the NCC, these drawings and all other relevant technical literature for this wind category. To comply with the requirements of the local authority
03 0 1 2 5 10
- A B C D E F G H I
APPROVED PLANS
17,014
MCU18/0135 OVERALL - REFER SHEETS 06 FOR COMPREHENSIVE DIMENSIONS
NOOSA COUNCIL ALL HABITABLE ROOMS WITH F.F.L 2.0m ABOVE
FINISHED GROUND TO HAVE LIMITED OPENINGS
(1.7m FROM TOP OF FLOOR LEVEL) OR SCREENING
27 NOVEMBER 2018 ENSURE TRACK
DRAINAGE TO MULLIONLESS CORNER TO
TO BE IN ACCORDANCE WITH NCC 3.9.2.5
- POCKET DOOR ENGINEERS/ BUILDERS DETAILS
SITE MEASURED
BUTT JOINT GLASS
710
900
900
2100x1000 DP DP
2700x2046SD
1 1
BJG
900
2100x1000
POCKET SD
270
BJG
0x2
90°
PO
100
CKE
28°
M
MS
DP
TS
D
BUILT IN DAYBED TO CABINET
MAKERS/ BUILDERS DETAILS
D
DP
TAP
ART PLASTIC CLASSIC DOWNPIPES 900 ENSURE TRACK
WITH FEATURE 45DEG GOOSE DRAINAGE TO
NECK CONNECTION TO THESE Living 700 POCKET DOOR
2100x3610 L
ONLY (STRICTLY NO COLLAR TIES)
(TILES)
2700 CEILING FEATURE TIMBER LOOK BATTENS (16x65mm
NOM WITH 10mm GAPS MAX) OVER DARK
R.L. 23.550 FC LINED WALL - REFER ELEVATIONS
BUILT IN FIRE PLACE FINAL MODEL
TBC BY BUILDER/ CLIENT - TO BE CLAMP FIXED GLASS BALUSTRADE WITH
INSTALLED STRICTLY AS PER 60mm (nom) WIDE METAL PLATE RAIL OVER
1000h DWARF MANUFACTURERS SPECIFICATIONS + VERTICAL LEG (1000h MIN FINISHED)
PLASTERBOARD WALL DP
2 2
DP
CP
DP OPEN TIMBER STAIR
OVERALL - REFER SHEETS 06 FOR COMPREHENSIVE DIMENSIONS
SUPPLY POWER TO
TREADS WITH EXPOSED ISLAND BENCH
UP TIMBER STRINGERS
4100x2090 F
FIXED GLASS WINDOW
12 13 14 15 16 17 18 19 20 21 900
02
04
TO HAVE MID BARS - GRAB RAIL TO
REFER PERSPECTIVE 12 11 10 09 08 07 06 05 04 BUILDERS DETAILS
VIEWS (3 PANELS)
1 SA SUPPLY TAP
270
TO REF.
REF.
0x6
PO
3 3
15,400
CKE
200
Kitchen
DP
Dining
2700 CEILING
OPEN TIMBER STAIR
TS
BUILT IN CUPBOARDS TO CABINET
MS
TREADS WITH EXPOSED P 1
D
C
(TILES)
MAKERS/ BUILDERS DETAILS
D
TIMBER STRINGERS 450x1910 F
Void WO
MW
(TILES)
2700 CEILING
Bal(TILES)
70°
TBC BY BUILDER
WO DW
FAN COIL UNIT
con
MW
IN CEILING
20°
FINAL CABINETRY
y
BBQ PLATE TBC
PANTRY
DP DESIGN/LAYOUT TO BY CLIENT/ BUILDER
M
CABINET MAKERS DETAILS
ALL EXPOSED MULLIONS
TO HAVE COVER-PLATES TO
4 4
DP
M
450x2000 A
MATCH WINDOW FRAMES
PANTRY
CUP'B OVER
Pwd.
2700x1100
(TILES) AC/ ELECTRICAL
2700 CEILING DUCT TBC SQ. SET
SA SA
FW
2340x770 MAN
DP HOLE 2400h (300mm FLOAT FROM
2700x1500
M
OPEN SHELVES OVER FLOOR) TIMBER LINED
FW FEATURE DWARF WALL
270
BUILDERS DETAILS
0x4
BUILT IN ROBE TO
600
450x2460 L
SA FULL HT FRAMELESS
MS
MIRROR
D
2340x1240
RENDERED & PAINTED Study W.I.R Master Ens. Master Bedroom
T/RAIL
NRG GREEN BOARD PACKOUT (TIMBER) (TIMBER) (TILES) (TIMBER)
DESK
900
NO DOOR
TO BUILDERS DETAILS 2700 CEILING 2700 CEILING 2700 CEILING 2700 CEILING 28°
R.L. 23.550
450x910
DP
M
2340x770
BJG
SHR 62°
270 BJG
NICHE TBC
450x720M FREE STANDING BATTEN FIXED PLASTERBOARD
0x9
DESK FEATURE
FG
BJG BUILT IN ROBE TO BATH TO BLOCKWORK WALLS
VIEWING SLOT
00
CUP'B OVER BUILDERS DETAILS
5 SITE MEASURED BUTT JOINT GLASS 2100x600 L SITE MEASURED
BUTT JOINT GLASS 5
1,200
2700x1480 L 2700x900
450x1450 A 450x1600 A 450x1000 A 450x1500 A DP DP
6 6
M BJG
900
900
800
OBS M OBS M OBS OBS
GRATED
DRAIN
AC DUCT TIMBER FLOOR
REBATE TO SHOWER
02 First LevelA Floor Plan 1:100 B C D 01 E F G H I
Revision Notes. Project Client Drawing Date Author
reitsma Figured dimensions only are to be taken from this drawing.
All dimensions, bearings, exis ng services, mandatory council
restraints/requirements and proposed levels are to be checked and
verified on site by builder/client prior to commencement of works.
All works must comply with NCC, local authority and all relevant
geographical/wind category requirements. All cut and fill ba ers
are indica ve only and must be established and verified by
builder/client in rela on to proposed slab and/or floor levels
N Murray Residence
Lot 15 Marcus Dunes Court
Planet Homes QLD
Builder
First Level Floor Plan 21/06/2018
Scale
TEAM
Revision
+61 7 5491 6834 13 Ridgewood Road. Any discrepancies must be communicated to the designer prior to These drawings are to be read in conjunc on with other
1:100 A
Caloundra commencement of works. Please note, builder specifica ons and relevant consultants drawings and reports. CASTAWAYS BEACH Stage Project Number Sheet Number
[email protected] QLD, 4551 signed contracts to take precedence over all Reitsma documenta on.
www.reitsma.com.au Australia © Reitsma+Associates Pty Ltd. A.T.F The Reitsma Family Trust ABN 62 631 178 013 - ACN 158 385 767 QBCC Lic. No. 1234490 BDAQ Member
Qld 4567 P: 54 96 0748 WORKING DRAWINGS 4425 4 /23
M: 0438 152 508
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU18-0135 - Approved Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 3.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.