Skip to the record
Every meeting, every word.

Original source · versioned page text

Appendix C - Site & Soil Evaluation and Effluent Disposal Report

of 9

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

216,7(())/8(17',6326$/5(3257/RW53:RRQJDU6W%RUHHQ3RLQW

,QWURGXFWLRQ

$XVWUDOLDQ6RLO,QYHVWLJDWLRQVKDYHFRQGXFWHGD6LWHDQG6RLO$VVHVVPHQWDWWKHDERYHDOORWPHQWIRUWKHSXUSRVH
RI GHWHUPLQLQJ WKH PRVW VXLWDEOH PHDQV RI RQVLWH HIIOXHQW GLVSRVDO  2QVLWH WHVWLQJ IRU WKLV DVVHVVPHQW ZDV
SHUIRUPHGLQDFFRUGDQFHZLWK$6³2Q6LWH'RPHVWLF:DVWHZDWHU0DQDJHPHQWDQGWKH4XHHQVODQG
3OXPELQJDQG:DVWHZDWHU&RGH
)LHOGZRUNIRUWKLVDVVHVVPHQWZDVXQGHUWDNHQRQWKH
7KLVDVVHVVPHQWKDVEHHQEDVHGXSRQWKHSURSRVHGSODQVSURYLGHGE\WKHFOLHQW

6LWHGHVFULSWLRQ

7KHDOORWPHQWLVORFDWHGZLWKLQWKH1RRVD&RXQFLODQGLVFRQWDLQHGZLWKLQDUHVLGHQWLDODUHD

7KH VORSH ZLWKLQ WKH DOORWPHQW LV JHQHUDOO\ OLQHDU SODQDU  7KH VORSH ZLWKLQ WKH DUHD EHVW VXLWHG IRU HIIOXHQW
GLVSRVDOLVLQWKHRUGHURI

2Q6LWH$VVHVVPHQW

'XULQJRXUVLWHHYDOXDWLRQFRQVLGHUDWLRQZDVJLYHQWRWKHIROORZLQJ

           WKHDYDLODEOHDUHDIRUWKHSULPDU\VLWLQJRIDEVRUSWLRQDUHDV /DQG$SSOLFDWLRQ$UHD DQGDOWHUQDWLYH
             VLJKWLQJV
      
           WKHULVNRISUHMXGLFLQJDGMRLQLQJSURSHUW\DQGXQGHUJURXQGZDWHUVXSSOLHVE\VHHSDJHRUUXQRII
             IURPWKHVLWH
      
           SHUPHDELOLW\VRLOW\SHDQGVRLOGHSWK
      
           GUDLQDJHDQGHQYLVDJHGVHDVRQDOFKDQJHVLQJURXQGZDWHUOHYHO
      
           JHQHUDOFOLPDWH
      
           VORSHDQGWKHHIIHFWVRIVHHSDJHDQGZDWHUUXQRIIIURPVXUURXQGLQJKLJKHUJURXQG

2Q6LWH7HVWLQJ

7KUHHWHVWKROHVZHUHH[FDYDWHGLQWKHSRVLWLRQVVKRZQLQWKHDWWDFKHGVLWHVNHWFK7KHVHKROHVZHUHPP
GLDPHWHU [  PP GHHS IRU WKH SXUSRVH RI VLWH VRLO DVVHVVPHQW LQ DFFRUGDQFH ZLWK WKH $6   $
IXUWKHU PP GLDPHWHU KROH ZDV H[FDYDWHG WR GHWHUPLQH WKH VRLO SURILOH  7KH VLWH ZDV WKHQ FODVVLILHG LQ
DFFRUGDQFHZLWK$6±2Q6LWH:DVWHZDWHU0DQDJHPHQWIRUWKHSXUSRVHVRIHIIOXHQWGLVSRVDO

5HVXOWV

6LWH2EVHUYDWLRQV
                                                                                      <HV           1R

6XLWDEOH$UHDIRUVLWLQJD/DQG$SSOLFDWLRQ$UHD                                         √

$GHTXDWHDUHDIRUD5HVHUYHDUHD                                                         √

,VWKHUH$GHTXDWH6RLO'HSWKGHSWKDERYHURFNRUWKHZDWHUWDEOH                        √

,VWKH6RLO7\SH6DWLVIDFWRU\                                                            √

,VWKHSRWHQWLDORIUXQRIIIURPWKHSURSRVHGDUHD2.                                     √

,VWKHUHDSRWHQWLDOIRUJURXQGZDWHUVHHSDJH                                                           √


$8675$/,$162,/,19(67,*$7,216                           3DJHRI                                        $6,5HI $ 


[OCR of page images]
ON-SITE EFFLUENT DISPOSAL REPORT: Lot 1 RP 112348, 20 Woongar St, Boreen Point.
Introduction:

Australian Soil Investigations have conducted a Site and Soil Assessment at the above allotment for the purpose
of determining the most suitable means of on-site effluent disposal. On-site testing for this assessment was
performed in accordance with AS 1547-2012-“On-Site Domestic Wastewater Management and the Queensland
Plumbing and Wastewater Code.

Field work for this assessment was undertaken, on the 30/11/2021.

This assessment has been based upon the proposed plans, provided by the client.

Site description:

The allotment is located within the Noosa Council and is contained within a residential area.

The slope within the allotment is generally linear planar. The slope within the area best suited for effluent
disposal is in the order of 4%.

On-Site Assessment:
During our site evaluation consideration was given to the following:

v the available area for the primary siting of absorption areas (Land Application Area) and alternative
sightings.

v the risk of prejudicing adjoining property and underground water supplies, by seepage or run off
from the site.

v permeability, soil type and soil depth.

v drainage, and envisaged seasonal changes in ground water level.

v general climate.

v slope and the effects of seepage and water run-off from surrounding higher ground.
On-Site Testing:
Three test holes were excavated in the positions shown in the attached site sketch. These holes were 100mm
diameter x 600 mm deep for the purpose of site soil assessment in accordance with the AS 1547-2012. A
further 100mm diameter hole was excavated to determine the soil profile. The site was then classified in
accordance with AS 1547-2012 On-Site Wastewater Management for the purposes of effluent disposal.

Results:

Site Observations
Yes No

Suitable Area for siting a Land Application Area
Adequate area for a Reserve area
Is there Adequate Soil Depth; depth above rock or the water table

Is the Soil Type Satisfactory

<a- 06 hUcHeCU AOS

Is the potential of runoff from the proposed area OK

Is there a potential for groundwater seepage V

AUSTRALIAN SOIL INVESTIGATIONS Page 2 of 6 ASI Ref: 210480(A)
Log in to download the original file

Appendix C - Site & Soil Evaluation and Effluent Disposal Report.pdf · 1.0 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.