Original source · versioned page text
Appendix C - Site & Soil Evaluation and Effluent Disposal Report
Site ‘Address 20 Woongar Street, Boreen Point State Qd Post Code 4565 Client Henk N. Cusack Date of Site Visit 30/11/2021 lame De rs Des Ph ~ “8825 W.R.Holmes signers Pn 428310453 Number 1120066 Name Number Plumber Ph Plumb / Drainer er TBA Plumber (TES) Number Lic Number we Council Designers AES 25 Noosa Cent Number Date 15/12/2021 This Calculator is a guide only, receiving soil classifi ce water, water tables and all other site constraints addressed by the qualified d >> This design is for an ADVANCED SECONDARY system Is this a new installation Y or N Y [>> Minimun single vent size is 80mm or 2 x 50mm house vents Number of person 5 a septic tank outlet filter is NOT RECOMMENDED Daily Design Flow Allowance Litre/Person/Day 120 Number of rows required to suit site constrants 4 >>Longer AES runs are better than multiplule short runs. Infiltration surface Soil Cat as est by site/soil evaluation. CATEGORY 4 >> Catagory may require design considerations. Ref AS1547 Design Loading Rate based on site & soil evaluation DLR (mm/day) 30 >> Soil conditioning may be necessary. Ref AS1547 & Comments. Bore log depth below system Basel area 2000__|>>Min depth below basel area 600mm check water table/restrictive laye Enter System footprint Slope in % for std AES systems to calc extension 4 >>Consideration reqd for Sloping sites. Ref AS1547. refer comment. Is this design a gravity system with no outlet filter? Y or N N >>HIGH & LOW vent requd on AES System includ velocity diffuser |COMMENTS :-" The outcome must be important to everyone. - Ripping of receiving surface required in clay soil structures in Cat 4,5,6. In ad. ition refer to AS 1547. Always excavate & rip paralld to the site slope/ AES pipe. - All Sloping sites require special consideration and management through design of slope percentage, surface water and construction methods as per AS1547. - Plumbers are reminded to practice good construction techniques as per AS 1547 & as provided on AES installation instructions supplied with components, Total System load - litres / day (Q). 600 od AES System __|_ System Extension Min Length of AES pipe rows to treat loading 50 Im Ith m:(L) 6.6 6.6 Number of FULL AES Pipe lengths per row 2 Iths Width mW) 2.25 0.78 Sand 0.75 0.15 Total Capacity of AES System pipe in Litres 1696 itr. Denth: . . Area m2 149 52 USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER y| IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Enter Custom Width in metre AES INFILTRATION FOOT PRINT AREA- L=Q/(DLRxW) | Length Width Minimum AES foot print required . for this Basic Serial design is 6.6 x 3.03 = 20.0 m2 total AES-PIPE AES 3 mtr Lths required 8 Iths Digitally signed by AESC AESC Couplings required 4 ca Steve Dennis AESO AESO Offset adaptors 8 ea DN: cn=Steve Dennis, o=Chankar| AESODV AES Oxgen demand vent 2 ea Enviromental, AES-IPB AES 100mm Inspection point base 2 ea © AbvANCED _ou=Design ‘nares Wastenatersoluions” Review, AES Equ AES Speed Flow Equaliser ca email=steve@envir AES DESC Double Offset Adaptors ea o-septic.com.au, TOTAL SYSTEM SAND REQUIRED (Guide Only) 14 m3 c=US Date: 2021.12.15 PLEASE email your / ‘ALC and Drawings to 10:43:54 +10'00' [email protected] [email protected] > The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer. > Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator. > AES pipes can be cut to length on site. They are supplied in 3 meter Iths only. AES-Design-V8.8-Calculator © Copy Right - Chankar Environmental pty Itd 14/3/2016
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original