beds are proposed and therefore no increase in the number of people onsite at risk of bushfire,
fully complying with the Bushfire Hazard Overlay Code.
Landslide Hazard Overlay Code
The land where the proposed extension is located is sloping and is identified in a High Landslide
Hazard area. The code seeks that people and property are safe from landslide and that
development is compatible with the nature of the hazard. A geotechnical report has been submitted
with the application to inform the engineering designs and future building application.
3.4. Details and Assessment of Requested Changes
Applicant’s Request
Kitchen Relocation: The existing kitchen will be relocated to a more convenient location within the
building, providing easier access for guests and better utilization of space.
Assessment of Request
This proposed change only involves an internal renovation of the existing building. The existing
kitchen is being located to the opposite side of the building to create a combined
kitchen/dining/living area, which was previously a covered deck area.
These modifications improve the functionality and amenity of the Rainforest Lodge without
significantly altering the overall character or use of the site and are supported.
Applicant’s Request
New Bathroom: A new bathroom will be added to improve the availability of ablution facilities,
ensuring guests have adequate amenities.
Assessment of Request
This proposed change only involves an internal renovation of the existing area where the kitchen
and Room 02 were located. The remainder of Room 2 is being converted into a kitchenette.
These modifications improve the functionality and amenity of the Rainforest Lodge without
significantly altering the overall character or use of the site and are supported.
Applicant’s Request
New Sitting Area: A comfortable sitting area will be created to provide a communal space for guests
to relax and socialize.
The new sitting room will be contained within the existing covered deck area on the north side of
the building. This space will provide a comfortable and inviting area for guests to gather.
Assessment of Request
It is agreed that this proposed change primarily involves internal renovations with a minor extension
to the building's footprint.
These modifications improve the functionality and amenity of the Rainforest Lodge without
significantly altering the overall character or use of the site.
Applicant’s Request
Reconfigured Bed Layout: The bed layout will be reconfigured to include six single bunk beds in a
dormitory style (12 beds/persons) and a two-bedroom accommodation unit with a King bed in each
room (2 persons in each King bed).
Page 7 of 12
Document Set ID: 23229506
Version: 8, Version Date: 17/12/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Minor Change Report MCU10/2017/01 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.9 MB (small file)
- File type
No other editions are linked here.