Skip to the record
Accept no imitations.

Original source · versioned page text

Attachment E - David Moore NOISE REPORT

Attached to the e-mail Response to Information Request - MCU17/0024.

of 34

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

The Surf Club Sunshine Beach
Environmental Noise Level Impact Assessment of Proposed Refurbished and Extended
Sunshine Beach Surf Life Saving Club, Duke Street, Sunshine Beach                                        Page 18 of 31




             APPENDIX A: AMBIENT NOISE MEASUREMENT EQUIPMENT, LOCATION A

Measurement Equipment

The following equipment was used to conduct the ambient noise level study at Monitoring Location A:

•   Bruel and Kjaer Type 2250 L Hand Held Analyzer – Serial No. 3004552, with Type BZ 7131, BZ
    7132 and BZ 7133 Software and Prepolarised free-field ½” microphone, Type 4189, Serial No.
    2879996;

•   Bruel and Kjaer Type 3592 outdoor microphone kit, including Type UA1404 outdoor microphone;

•   Bruel and Kjaer Type AO 0442 ten metre microphone extension cable; and

•   Bruel and Kjaer Type 4231 Sound Level Calibrator, Serial No. 2292736.

All of the above equipment is Type 1 in accordance with the requirements of Australian Standard AS
1259-1990, Acoustics – Sound Level Meters, as required by Australian Standard AS 1055.1-1997.


Measurement Equipment Settings

The above equipment was used with the following settings:

•   Detector:                        RMS
•   Time Weighting:                  FAST
•   Frequency Weighting:             A
•   Sound Incidence:                 FRONTAL
•   Microphone sensitivity:          49.021 mV/Pa


Calibration

The sound level meter was calibrated to the required value of 93.8 dB at 1000 Hz immediately before
and after the noise level measurements were conducted. At no time was an adjustment of more than
0.5 dB required. This complies with the requirements of the Australian Standard.


Monitoring Location

Monitoring Location A was on the south-eastern facing balcony of Unit 5, first floor level, Costa Nova, 1
Belmore Terrace, Sunshine Beach with the microphone elevated 1.6 metres above balcony level. Refer
Figure 1 for further details.


Atmospheric Conditions

Throughout the ambient noise level study, atmospheric conditions complied with the requirements of the
Australian Standard. Refer Appendix E for details of atmospheric conditions at the closest recording
weather station to the subject site, namely Double Island Point.




David Moore & Associates Pty Ltd                                            Our reference: R17049/D3248/Rev.0/21.07.17
Log in to download the original file

Attachment E - David Moore NOISE REPORT.pdf · 3.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.