App 5 - Wastewater Design
Sunshine Coast Office
PO Box 6218
Mooloolah Valley Q4553
P. 0407 887 321
E. [email protected]
BioWater Designs Pty Ltd
QBCC Lic 1049265
SHED WITH AMENITIES
&
FUTURE STABLES
SITE & SOIL EVALUATION
Lot 3 RP 851976
Area: 256269.38m2
Address: 328 Upper Pinbarren Creek Rd, Pinbarren
Date: 18th February 2019
Reference No: UPinbarren/328/2019
INDEX:
1.0 Introduction: IMPORTANT DIRECTION
Do not install from this design until it is
2.0 Site Description: p2 Stamped and Approved by the Local Authority.
3.0 Soil Investigation: Council may make changes to this design as part
of the approval process. Only install from Stamped
3.3 Soil Classification Approved Plans and refer to the Approval Permit for
4.0 Recommendations: p3 possible changes.
5.0 Design Calculation
5.1 AES Infiltration Bed Design: p4
p5 reuse
AES Calculator
7.0 Design Drawings p6 recycle
7.1 Design Drawings p7
retrieve
Borelogs p8 & 9
Appendix A - Inspection Port p10 C Copyright Lance Picton 2019 design & content. 1/10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 9 pages
Page 2
1.0 Introduction:
Biowater Designs Pty Ltd, in accordance with AS/NZS1547-2000 ( Domestic Wastewater Management ) and the
Queensland Plumbing & Wastewater code (QPW), was commissioned to undertake a Site & Soil Evaluation in the
Noosa Council at 328 Upper Pinbarren Creek Road, Pinbarren.
The results form the basis of our recommendations for on site wastewater disposal.
Our Site investigation and field work was performed on Friday 15th February 2019 after a period of wet weather.
The investigation was undertaken to determine the soil profile and Long Term Acceptance Rate (LTAR) of the site in
order to accommodate proposed amenities (shower, toilet and 2 handbasins) in a shed/workshop and future stables with
a washing machine and handbasin. No kitchen facilities or bedrooms to be installed.
NOTE: This evaluation was undertaken at the owner’s request after considerable discussion regarding environmental
issues of this site and preferred design of the Land Application Area.
2.0 Site Description:
2.1 Existing Buildings: Dwellings & Sheds. The existing dwellings do not form part of this assessment.
2.2 Site Factors:
The site is a large acreage allotment the area is 256269.38m2.
The proposed Land Application Area is slightly sloping (3%) to the South-East.
The proposed Land Application Area has very good exposure to sun and wind.
Erosion, mass movement or land slip was not observed on this site. Rock outcrops are not evident on this site.
Vegetation on this site consists of small to large trees and shrubs of various species and has 100% grass cover.
There are no bores on this site or adjoining properties within the required setbacks of the proposed Advanced Enviro-
Septic Bed.
There is a small creek at the front of the property, several dams and intermittent waterways across the site. Setback
requirements under ASNZS 1547:2000 for Advanced Secondary Effluent are obtainable.
Ground water was not encountered on this site during our investigation to a depth of 1500mm.
There is no evidence of fill in the proposed Land Application Area.
Rain water will transverse this site from adjoining properties during heavy rains.
Concentrated run-off from this property will transverse adjoining properties during heavy rains.
Soils were moist and there is no evidence of soil surface cracking. No evidence of compaction or seepage areas.
Salinity is not evident.
3.0 Soil Investigation:
3.1 Drainage Pattern: Linear Planar
3.2 Method:
Soil Testing for the site was conducted by Global Testing on 29th January 2019 to a depth of 1500mm. See borelogs attached.
The soils were visual one textually classified in accordance with AS/NZS 1547:2000. The soils were
predominately red/brown in colour. Strongly structured Sandy Clay.
Forms a plastic ball in which sand grains can be seen; felt or heard; forms a ribbon
50-75 mm long. Category 5 adopted.
C Copyright Lance Picton 2019 design & content. 2/10
Page 3
3.3 Soil Classification
Soil Classification - Adopted
Borehole Nos 1&2
Soil Category Adopted 5
Indicative Drainage Poorly Drained
Structure Strongly
Texture Sandy Clay
Indicative Permeability P (m/d) as Ksat* 0.12 - 0.5
Recommended DLR(AS/NZS 1547 / 2000) 10
4.0 Recommendations:
4.1 Treatment Facility:
The on-site treatment facility to service the new detached dwelling is to be an Advanced Enviro-Septic System (AES).
This system has a Chief Executive Approval # 14/2014 for Advanced Secondary Effluent. The Equivalent Person
(EP) for this system is to be no less than 2.
A new min 3000lt septic tank is to be installed to service the amenities in the shed/workshop and stables. This tank
must comply with AS/NZS:1546. All wastewater from these amenities is to be directed to the septic tank then to the
AES bed.
The Land Application Area is to be an Advanced Enviro-Septic Infiltration Bed of 24m2.
5.0 Design Calculation
The serviceable life of the Land Application Area will be compromised if the design flow is exceeded. Any
proposed changes to the position of the Land Application Area, System Type or House Design will require a
reassessment of this site. For our calculations we have assessed the design flow as follows:
Design Calculation
DLR (mm/d) (secondary quality effluent) 10
Hydraulic load (lt/day/person) Tank Water / 1 bedroom equivalent 120
Design Flow Q (lt/day) EP: 2 240
Design sizing calculation L = Q /(DLRxW)
= (240 / 10)
Disposal area A+B (square metres) AS/NZS1547:2000 24m2
Nominated Configuration (metres) AES System Design Calculations = 6.6 x 3.64m (L xW) 24m2
A new 3000L Septic Tank is required. AES System EP 2
C Copyright Lance Picton 2019 design & content. 3/10
Page 4
5.1 AES Infiltration Bed Design. Advanced Enviro-Septic System
The AES Bed Design is to be a gravity fed, belowground system. See system design drawings page 6.
The total bed base required is 24m2 (6.6m x 3.64m). Bed is to be installed as shown on the site plan. See drawings page 6 for bed
profile. A minimum 4m setback is required to any tree.
The entire bed base it to be ripped 300mm parallel to the AES pipes and gypsum applied at 1kg per m2.
Coarse washed sand will be referred to as “system sand” and must meet the specifications of the system manufacturer.
System sand will need to be placed around AES pipework and for the infiltration area as shown on the attached drawings.
System pipe bed dimensions (Area A) are 6.6m long by 1.35m wide and a total minimum sand depth of 750mm. 300mm of
course washed sand is to be spread to form a base and 2 rows of 2 lengths of AES pipes installed as per the attached drawings.
A further infiltration area 6.6m x 2.29m (Area B) is to be constructed below the pipe bed as per the site drawings and a minimum
of 150mm system sand to be spread over the entire infiltration area.
Pipes are to be covered by a minimum of 150mm of system sand. A further 150mm of site soil is to be mounded over the sand to
prevent surface water entering the bed. After all settlement the AES Bed is to have a minimum 150mm cover of site soil.
Beds are to be constructed in accordance with the AES Design and Installation Manual and all plumbing works in accordance with
the QPW code. All site work is to be carried out by a licenced plumber and all AES horizontal pipes laid with the aid of a laser or
dumpy level to ensure absolute compliance with the manufacturers installation guidelines. This is critical for correct operation.
Oxygen Demand Vents are to be installed as per the AES Design & Installation Manual. The high vent (100mm) to be installed
on the shed/workshop must be a minimum of 3m higher than the AES low vent and provide unrestricted air flow through the
entire system. (See attached drawing for illustrations.)
Two Inspection Ports are to be installed, one in the centre of the pipe bed and another at the furthest point from the influent to AES
Pipes. See Installation Instructions Appendix A - page 9.
Care must be exercised to prevent machinery access on the AES bed during and after construction.
6.0 Setback Regulations:
Secondary Advanced Secondary
Recommended Separations Distances - Surface Irrigation
Effluent Effluent
Dwellings & recreation areas 10m 10m
Water edge of swimming pools 6m 6m
Property boundaries, paths & walkways 2m uphill 2m uphill
4m down hill 4m down hill
Top of bank of permanent water course, creek, lake, waterway etc. 30m 10m
Bore or Dam for domestic or stock use 30m 10m
Vertical depth of seasonal water table 0.6m 0.3m
In ground potable water tank. Note some authorities require 15m 6m 6m
Sub-Surface Irrigation same as above except for;
Dwelling & recreation areas 4m 4m
NOTE: The local government authority may upon considering the public health and environmental risks
reduce or increase the distances in the above table.
Regards,
Lance Picton jp.
Site Classifier
QBCC Lic: 1049265
C Copyright Lance Picton 2019 design & content. 4/10
Page 5
5/10 [OCR of page images] ADVANCED ENVIRO-SEPTIC’ Advanced Enviro-septic Design Calculator V8.6 © “Always The First Option” "Always the BEST Option" until site and soil conditions rule it out. Site ‘Addiess 328 Upper Pinbarren Creek Rd, Pinbarren State Qld Post Code 4568 Client “tent Viki Dioszegi Date of Site Visit 15/2/19 Name De s De s Ph ® <SIENETS 5 water Designs Pty Lid signers 0407 887 321 Number 1049265, Name Number ™ Phanb. Plumber Ph Plumb / Drainer umber Number Lic Number Cc cil Des: rs AES one" “Noosa Council Stenes AESBR000001 Date 18/2/19 Area, Cert Number This Calculator is a guide only, receiving soil classification, surface water, water tables and all other site constraints addressed by the qualified designer. IMPORTANT NOTES fe/meter loading rate, "30" for Advanced Secondary or "38" Secondary 30 [>> This design is for an ADVANCED SECONDARY system Is this a new installation Y or N Y >> Minimun single vent size is 80mm or 2 x 50mm house vents Number of person 2 a septic tank outlet filter is NOT RECOMMENDED Daily Design Flow Allowance Litre/Person/Day 120 Number of rows required to suit site constrants 2 >> The maximum Ith of a single AES pipe run is 30 meters irface Soil Category as established by site and soil evaluation. CATEGORY 5 >> Catagory may require design considerations. Ref AS 1547 Design Loading Rate based on site & soil evaluation DLR (mm/day) 10 >> Soil conditioning may be necessary. Ref AS1547 & Comments. Bore log depth below system Basel area 600 >> Min depth below basel area is 600 mm to establish water table or re Enter System footprint Slope in % for standard AES systems to calculat| 3 >> Consideration required for Sloping sites. Ref AS1547. refer comme! Is this design a gravity system with no outlet filter?’ Y or N y >> A House Vent & LOW VENT required on this system PLEASE CHECK YOU HAVE FALL FROM TANK TO AES SYSTEM PIPES COMMENTS :-" The outcome must be important to everyone. " - Ripping of receiving surface is required in clay soil structures in Cat 4,5,6. In addition refer to AS 1547. Always excavate and rip parallel to the site slope/AES pij - Specialist soils advice and special design techniques will be required for clay dominated soil having dispersive or shrink/swell behaviour. Refer AS1547 = Designers need to be familar with special requirements of Local Authorities. IE - Minimun falls from Septic tank outlets to Land application areas. ete - Plumbers are reminded that good construction techniques as per AS1547 are especilly important in these soil types. Refer AS1547 & AES installation Instructions Total System load - litres /day (Q). 240 Wid AES System System Extension Min Length of AES pipe rows to treat loading 4.0 Im Lith m : (L) 6.6 6.6 Number of FULL AES Pipe lengths per row 2 Iths Width m:(W. 1.35 2.29 and 0.75 0.15 Total Capacity of AES System pipe in Litres 848 Itr. Death : .S Area m2 8.9 15.1 IDO YOU WISH TO USE CUT LENGTHS OF PIPE IN THIS DESIGN? (ENTER Y) | IF YOU WISH TO USE A TRENCH EXTENSION DESIGN OPTION ENTER "Y" Enter Custom Width in metre AES INFILTRATION FOOT PRINT AREA - L=Q/(DLRx W) Length Width Minimum AES foot print required . for this Basic Serial design is 6.6 x 3.64 = 24.0 m2 total SSSne ese Chankar Environmental Use Only AES-PIPE AES 3 mtr Lths required 4 Iths Digitally signed by ARSC ESC Coupl od 2 Steve Dennis AESC s ‘ouplings requir ca DN: cn=Steve AESO AESO Offset adaptors 4 ea Dennis, AESODV AES Oxgen demand vent 1 ca o=Chandar _ Enviromental, AES-IPB AES 100mm Inspection point base 2 ca CQERVIRE Se pTc” ou=Resign Review, i™ "Nature's Wastewater Solutions” ' AES Equ AES Speed Flow Equaliser ca email=designrevie w@enviro- AES DESC Double Offset Adaptors ea septic. comany TOTAL SYSTEM SAND REQUIRED (Guide Only) ut m3 c=AU Date: 2019.02.18 13:31:38 +10'00' [email protected] PLEASE email your AES CALC and Drawings to [email protected] > The AES Calculator is a design aid to allow checking of the AES components and configuration and is a guide only. Site and soil conditions referencing the AS 1547 standard are calculated and designed by a Quailified Designer > Chankar Environmental has no responsibility for the soil evaluation, loading calculations or DLR entered by the designer for this calculator > AES pipes can be cut to lenght on site. They are supplied in 3 meter lths only. AES -Design-V8.6-Calculator ©__Copy Right - Chankar Environmental pty Itd 14/3/2016 5/10
Page 6
7.0 Design Drawings THIS PLAN IS SITE SPECIFIC FOR 328 Upper Pinbarren Creek Rd, Pinbarren
6.6m
6m
level Inlet
1350mm
pack sand
under 300mm
Note: Vent Ground level
Correct installation of connectors
in AES Manual page 9.
Area A
Area B
Entire bed base is to be ripped
300mm parallel to AES Pipes
3.64m
Gypsum applied at 1kg / m2.
Infiltration Extension Area
6.6m x 2.29m x 150mm system sand.
IMPORTANT NOTES PLEASE READ. Inspection Port to be installed
at furthest point from Influent
to AES Pipes - see Appendix Page 9
The installer MUST refer to the Advanced Enviro-Septic Design & Installation for installation instructions
Manual provided. If you do not have a copy of this manual please contact Chankar
Environmental and a copy will be emailed FREE.
Sections C, D, & E of the Design and Installation Manual are of particular relevance
Inspection Port to be installed
when installing an Advanced Enviro-Septic System.
between AES Pipes - see
Appendix Page 9
THIS IS NOT A SEPTIC TRENCH AND MUST BE INSTALLED AS PER THE
for installation instructions
AES DESIGN AND INSTALLATION MANUAL GUIDELINES.
Ensure you have the correct sand and all fittings to complete the installation if you
are unsure of anything please contact Chankar Environmental (07) 54 744 055 or
Biowater Designs 0407 887 321.
Imported sand (course washed)
Backfill with site soil min 150mm cover over sand
and mound soil over bed to prevent water access.
300mm Inspection Port
Inspection Port
3% slope 150mm
Natural Ground Level
150mm
Inlet AES pipe
750mm
150mm
300mm
300mm
300mm 300mm
Rip & Gypsum 300mm parallel to pipes 8/9
9/9300mm 150mm
Sand
2290mm 1350mm
AES Sand Coverage Minimums
C Lance Picton 2019 all rights reserved 6/10
Page 7
7.0 SITE PLAN. This plan is site specific for; 328 Upper Pinbarren Creek Road, Pinbarren
ce Very large
Proposed stable with fen
fig tree
washing machine and
hand basin.
Existing shed with
proposed amenities
shower/toilet/hand basins.
3000lt septic
tank (indicative position)
Existing machinery
shed and container er Large Dam
to be relocated 2m tain
con
4m 21
Proposed AES bed m
6.6m x 3.65m (See Soil tests
page 6 for detail)
INSERT Scale: 1:950 @ A3 INSERT
Quick Reference (read in conjunction with report)
AES System Pipes 4 Gravity Fed System
AES Offset Adapters 4 Pump To System
AES Pipe Connectors 2 Existing Pump
Vents 1 Non Return Valve IMPORTANT DIRECTION
11 m 3 Do not install from this design until it is
System Sand Velocity Reducer
Stamped and Approved by the Local Authority.
Total System Footprint 24 m2 Council may make changes to this design as part
New Septic Tank Required Min 3000L
N of the approval process. Only install from Stamped
Approved Plans and refer to the Approval Permit for
Existing Septic Tank
Diversion Mound possible changes.
Existing Composting
Biowater Designs Pty Ltd Plan of: Client: This plan to be read in conjunction with the
All plumbing works to be performed by a licenced plumber
PO Box 6218 Lot 3 RP 851976 Viki Dioszegi attached report.
and must comply with the Queensland Plumbing &
Mooloolah Valley Q 4553 328 Upper Pinbarren Creek Rd, Ph: 0477 741 141 The proposed Land Application Area must be
Wastewater code. LAA setbacks must comply with
Ph: 07 54 947 620 Pinbarren installed and positioned as per this plan.
AS/NZS1547:2000 as setout on page 4 of this report.
M: 0407 887 321 Construction of any permanent structures
within the designated area is prohibited.
Site Classifier: SCALE: Site Area: 256269.38m2
Local Authority: Date: Care must be taken to ensure no traffic or fill
Lance Picton jp INSERT only: 1:950@ A3 LA A: 24m2
Noosa Council 18/02/2019 in the designated area during construction. C Copyright Lance Picton 2019 design & content. 7/10
QBCC Lic 1049265
Page 8
8/10 [OCR of page images] GLODAL TESTING THE ONLY NAME IN SOILS SOIL PROFILE REPORT CLIENT: Viki Dioszegi AUTHORIZED BY: Viki Dioszegi PROJECT: 328 Upper Pinbarren Creek Rd, DATE TESTED: 29/01/19 Pinbarren. JOB NO: 17/0752 Drilling Method: Jacro 105 100mm Borehole No: 1 Depth (mmm) Description PENET. Permeability — Test Result PT] a Pala (mid) - (Ksat) 0 SANDY CLAY (CL)- Low plasticity, pale brown, fine to medium sand, moist, stiff. 100 (category 4, weakly structured). 200 300 400 0.20 500 SANDY CLAY (CI}- Medium plasticity, red/brown, fine to medium sand, moist, stiff. (category 5, strongly structured). 600 700 800 900 1000 1100 1200 1300 1400 I 1500 Hole Terminated. 1600 } 1700 ] 1800 1900 i 2000 | | 2100 2200 2300 2400 2500 Borelogging in accoedance with AS1726-1993 Site Investigation Cade 8/10
Page 9
9/10 [OCR of page images] DAT Pre Til ULODAL TESLING THE ONLY NAME IN SOILS SOTL PROFILE REPORT CLIENT: Viki Dioszegi AUTHORIZED BY: Viki Dioszegi PROJECT; 328 Upper Pinbarren Creek Rd, DATE TESTED: 29/01/19 Pinbarren, JOB NO: 17/0752 Drilling Method; Jacro 105 100mm Borehole Na: 2 Depth (mm) Description PENET, Permeability (blows per 100nam) ao 1 2 3 14 (Ksat) 0 SANDY CLAY (CL)- Low plasticity, pale brown, fine to medium sand, moist, stiff. 100 | (category 4, weakly structured). 200 300 400 0.22 500 SANDY CLAY (CI- Medium plasticity, red’browg, line to medium sand, moist, stiff. (category 5, strongly structured). 600 700 800 900 _1000— 1100 1200 1300 1400 1500 Hole Terminated. 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 Borelogging in accordance with AS1 726-1992 Sile Investigution Code 9/10
Page 10
10/10
-
o
t-
lL
o
{U E
E l-
5
\t
()
5
3' o
lr dr-
2 2
o
$u C'
td
c'
63 E
o
L
!,
o\1
ts !(t
td
iE
CI
H* UI
-,li H
l-
l-
F
tJ
."
lrl
o
E
a o-
=
6 |o rO
tF
rt
t a
(F 1a- rF
.?
F o a
o 3 a
g ct ct C}
Ut
u
I
l- $
0*
ut i;
$
{
051 il 9d
ln as
=:
HR r inz
l{ut
IFi
F$E
€rt
Appendix A - Inspection Port Installation
t.,;.o
-
J
E
LlE
6
IK
3tr
i5
iE,I
HE
zvt
g,
Ei
.a
1?N
.l
rd h,
l-F
9?