ADAMS + SPARKES Town Planning Report (30 & 32 The Cockleshell)

Attached to the e-mail MCU17/0563, OPW17/0597 & RAL17/0513 - Material Change of Use, Op Works & Recon (access easement) - 30 & 32 The Cockleshell, Noosaville.

of 68

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Original PDF page 33, section 1. The text section number identifies this passage in the reader.

                    EXISTING TELSTRA                                                                                                                                                                                                        LEGEND

                                                                                                                                                                                                                                                                 PROPOSED BUILDINGS
                    EXISTING
                    ELECTRICITY
                                                                             RETAINING WALL BY OTHERS -                                                                                                                                                          PROPOSED DRIVEWAY
                                                                             REFER STRUCTURAL
                                                                             ENGINEERS DETAILS                                                                                                                                                                   EXISTING STORMWATER
         EXISTING DRIVEWAY TO BE                                                                                                                                                                      EXISTING SEWER
         REMOVED, KERB AND CHANNEL                                                                                                                                                                                                                               EXISTING SEWER MAIN
         AND VERGE TO BE REINSTATED                                                                                                                                                                                                                              EXISTING WATERMAIN
         IN ACCORDANCE WITH COUNCIL                                                                                                                                                                                                                              EXISTING ENERGEX - UNDERGROUND
         REQUIREMENTS
                                                                                                                                                                                                                                                                 EXISTING TELSTRA
                                                                                                                                                                                                                                                                 PROPOSED RETAINING WALLS
                                                                                                                                                                                                                                                                 (BY OTHERS)

                                                                                                                                                                                                                                                                 PROPOSED KERB ADAPTORS




                                                               90mm DIA uPVC STORMWATER
                                                               CONNECTION. GRATED DRAIN TO
                                                               CONNECT TO KERB ADAPTORS

                                                                                 'ENTRY ONLY' SIGN




                                   THE COCKLESHELL
 NEW KERB ADAPTER IN
 ACCORDANCE WITH IPWEA STD
 DWG RS-081



                                                                                         LINEMARKING
 PROPOSED DRIVEWAYS AS PER
 IPWEA STD DRG RS-049
 (TYPE 5) & RS-050
   EXISTING WATER                                                                                                     PROPOSED FIELD INLET PIT
   METER TO BE                                                                                                        (TYPE 2B) TO CONNECT TO                                                         EXISTING STORMWATER
   RELOCATED                                                                                                          COUNCIL'S STORMWATER PIPE.
                                                                                                                      AS PER IPWEA STD DRG DS-050
                       'NO ENTRY' SIGN


EXISTING WATER
METER TO BE
RELOCATED
PROPOSED DRIVEWAYS AS PER                                                                LINEMARKING
IPWEA STD DRG RS-049
(TYPE 5) & RS-050                                         'EXIT ONLY' SIGN

       EXISTING KERB AND CHANNEL


 NEW KERB ADAPTER IN
 ACCORDANCE WITH IPWEA STD
 DWG RS-081
                                                                  90mm DIA uPVC STORMWATER
                                                                  CONNECTION. GRATED DRAIN TO
                                                                  CONNECT TO KERB ADAPTORS
      EXISTING DRIVEWAY TO BE                                                                                                                                                                          EXISTING SEWER
      REMOVED, KERB AND CHANNEL
      AND VERGE TO BE REINSTATED
      IN ACCORDANCE WITH COUNCIL                                                                             UP                                 UP
      REQUIREMENTS




       PROPOSED 1.5m FOOTPATH AS                       1.50m
       PER IPWEA STD DRG RS-065



                                                                                                                                                                                                                                 CAUTION -
                                                                                                                                                                                                                                 EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT
                                                                                                                                                                                                                                 LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE
                                                                                                                                                                                                                                 PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION.
                                                                                                                                                                                                                                 THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO
                                                                                                                                                                                                                                 EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.




                                                                        No     Date                       Amendment                                               FOR APPROVAL            CLIENT:    JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN
    360 CIVIL CONSULTING PTY LTD                                                                                                      Design:   J.A.G                                                                                                                               JOB NUMBER
                        ABN: 13 609 593 339                                                                                           Drawn:    J.A.G                                     PROJECT:   PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
                                                                                                                                                                                                                                                                                        2017115
           23 OOGAR STREET, MAROOCHYDORE. QLD 4558                                                                                    Date:     04/11//17                                 AT:   30-32 COCKLESHELL, NOOSAVILLE
                                                                                                                                                            BEATRICE GIBBERD RPEQ 14557                                                                                             DRAWING No:
   Mobile: 0403 862 009  Email: [email protected]                                                                    Checked: B.G.            DATE:    04/11/2017              LOT 11 ON RP138550 & 0 BUP6971
 THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.                                                                                                                                                                                                                       03 of 10
                                                                                                                                      Datum:    A.H.D.          Size:      A3             TITLE: STORMWATER AND DEVELOPMENT LAYOUT PLAN
Log in to download the original file

ADAMS + SPARKES Town Planning Report (30 & 32 The Cockleshell).pdf · 5.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.