Zatices & Vees         Design-In-Hyne v5        Hyne & Son Pty Ltd         Deflection Report
                                                                          Job Number
                                       WL                                 Job Description
                                                                            un by: Nova Desighn Group Pty Ltd_on 26/02/2007, at 12:91:31 PM___ Phone: 07 54472996
                                                                          This design was Carried out using AS1684.1-1999 as the preferred code for
                                                                          design of this domestic building element
                                               it tt
                           SEEN              pt                           Section R1, Roof Purlin Design
                            i  |                                          Use preferred section size Ht 20070 HYNE I-BEAM from Hyne & Son Pty Lid
                  LL                  ML                                  DIMENSIONAL DETAILS
                          |            Wi                                 Span type is Single Span for an overall length of 6.2 metres
                                                                          Roof Purlin spacing is 1.2 metre centres

                                                                          DESIGN DETAILS
                                                                          Roofing material of Light Sheet (10) No ceiling load has been allowed
                                                                          Roof pitch of 10 deg
             |                                                            Wind Classification for this project is N2 Design ultimate wind pressure is 0.960 kPa
    (Ho      |                      R         ee ET NS Sete               Temperature Factor (K6)  1.00 Design serviceability wind pressure is 0.406kPa
                            Pd            IN                              Allowable Deflections        L/300  20
                         -                                                Load Case Type           Span Ratio     Fixed value mm
                                                                          Permanent Loads
                                                                           Permanent Loads             L/300  20
                                                                           Long Term Snow Loads        L/250 nla
                                                                          Short Term Snow Loads        L/250 nla
                                                                           Roof Live Loads       L/250 nla
                                                                          Wind Loads             L/150 n/a
                                                                          Wind Loads             L/150 n/a

                                                                           Member Actions - Serviceability Properties
                 ROOF PLAN                     UPLIFT 50.29kN              Member   toad Combination Name                     Bending    Shear      Total    Check
                                                                           Number                                              Deflection Deflection Deflection Deflection
                                                                              1 Dead Load Oniy                                -11.8       4 4       ~13.        13.2
                                                                                                                                          1.4
                                                                                Wind Uplift Only                              19.8       24         22.2        22.2
                 ROOF STRUCTURE                                                                                                                  LINDSAY C%        FUL, TING
                                                                                                                                                                              L7o
            1                                                                                                                    | /STRU   a     CSTR OPAL ab ouyil 7 ay Wreene > Us
          NU?     1: 100                                                                                                                                      L/L LZ<             oi
   Nova Design Group Pry Lid                                             Proposed Renovations                                                    oF. eee PARE get Ana  ec PH 56 192 179
                                                                                                                                                              1    LAIN
         P.O. Box 651 Noosa Heads Qld 4567               Carloyn Searle & Brian Ward                25 Adam Street Sunshine Beach | Project number   1007/4 |
                 Tel: 07 54 472 996                                                                                              | Date         February 2007       AQ
         email: [email protected]                                                                                         Drawn by            mp
                                                                                                                                  Checked by          mp . Scale             4° 100
                                                                                             —<—<—$———                        —w              _~
ee ee

Used in these records

About this file

File size
2.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

001593F0.001.pdf · 2.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.