Skip to the record
Trusted by locals. Built for Noosa.

Council archive · source document

001593F0.001

of 39

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn

Text sections not matched to the original PDF pages. See original document to check page numbers.

rv     a

      5.       SITE CLASSIFICATION AND TARGET STRATA
               Based on the findings of the site investigation and the footing system design proposed on the
               client supplied information, the classification of the site is considered to conform to: -
                                               CLASS "S"

               in accordance with Australian Standard 2870 - 1996, 'Residential Slabs and Footings,
               Construction’.

               The target stratum for the foundation of the structure is the silty sand which occurs
               from the existing ground level. Any fill placed over the existing ground shall be piered
               through the fill into the existing material. Further note that the placement of reactive
               material as fill may change the site’s classification.

      6.       FOOTING SYSTEM DESIGN
               The footing system shal! be designed to conform to the performance limits stated in AS 2870
               — 1996 and reprinted in the C.S.1.R.O.'s Publication 10/91, 'Guide to Home Owners on
               Foundation Maintenance and Footing Performance’, a copy of which attached to this report. It
               should be noted that footings designed in accordance with AS2870-1996 does not guarantee
               no movement of footings, shrinkage cracking or other damage to the building.
               Foundation preparation and footing construction shall be in accordance AS 2870 -1996 and
               AS 3798-1990 ‘Guidelines on Earthworks for Commercial and Residential Developments’.
               Where necessary, subsoil drainage shall be incorporated in the construction of the building to
               ensure that subsurface water is properly drained away from the footings.
               Potential seepage or subsoil drainage problems cannot always be recognised from the results
               of a site investigation. Problems with respect to subsurface water flow or seepage may not be
               evident until after the site has been subject to the first significant wet period.
               After construction of the footing system the ground surface around the residence shall be
               sloped away from the footings at a fall of 1 in 20 minimum for a distance of 2000 mm.

       7.      ARTICULATION
               It is recommended that masonry walls on Class M, H, E and P sites be articulated at all or
               some openings. Articulation joints shall be constructed in accordance with the Cement
               and Concrete Association's Publication 'TN61 - Articulated Walling’.

                                                      2

Used in these records

About this file

File size
2.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

001593F0.001.pdf · 2.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.