Council archive · source document
Attachment 1 - Code Assessment · MCU23/0030
Attachment 1 – Code Assessments
Performance Outcomes Acceptable Outcomes Response
AO9.3 Performance Outcome
Buildings and structures meet the following The proposed dwelling is generally in accordance
minimum setbacks to boundaries other than road with the acceptable outcomes, being 1.5 metres
frontages and rear boundaries: setback for the first floor and 2 metres for the
second floor. The portion of the building above 7.5
1. 1.5 metre setback up to 4.5 metres height;
metres is setback 2 metres from the boundary. The
2. 2 metres setback between 4.5 metres and proposed relaxation is consistent with the
7.5 metres height; and surrounding and adjoining dwellings and does not
cause adverse impacts upon amenity and the
3. 2.5 metres if above 7.5 metres height.
character of the locality.
AO9.4 Noted
Notwithstanding the provisions of AO9.2 and
AO9.3, a lesser building setback to:
1. side and rear boundaries may apply for the
following provided they comply with the
Queensland Development Code:
1. open carport;
2. swimming pool, garage/shed; and
3. rainwater tank, retaining walls,
screens and fences not exceeding 2
metres in height; and