Log in to see the plans as drawn BC BARGE CAPPING - COLORBOND
BLK1 CORE FILLED R.C BLOCK WALL REFER
TO ENGINEERS DETAIL
CN1 RC CONCRETE NATURAL FINISH
COL COLUMN REFER TO ENGINEERS
800 DRAWINGS FOR DETAILS
800 DP DOWNPIPES WITH LEAF GAURDS SHOWN
800 INDICATIVE. DRAIN TO RAIN WATER
131452 P1 5° 131452 TANK REFER HYDRAULIC CONSULTANTS
600
P1 DRAWINGS FOR DETAILS
RS1 1200 RS1 BC
600 EG
EG COLORBOND EAVES GUTTER & FASCIA
EG BC EG-R RAKING COLORBOND EAVES GUTTER &
R1 TS EG P1
2 EG DP FASCIA
P1 FG FIXED GLASS
COL
129850 DP HC HOSE COCK
TS P1
BLK1 2427 SD HR-A PROPRIETARY HANDRAIL TYPE A AS
2418 SD 2410 2406 2409
2650
SBR COL SELECTED
1300 LVR LVR BLK1 LVR
WT1 LVR ADJUSTABLE GLASS LOUVRES AS
SBR HR-A
R1 N-PF SELECTED. OBSCURE GLASS TO
TS
1 DP BATHROOM & WC AREAS
N-PF PROPRIETARY GLASS POOL FENCE AS
127200 R1 SELECTED
CN1 CN1
BLK1 R1 R1 P1 PAINT FINISH - COLOR CHARCOAL
COL P2 PAINT FINISH - COLOR OLIVE GREEN
3000
RCPW CN1 R1 RENDER FINISH - COLOR CHARCOAL
BLK1 2151
RCPW INSITU CONCRETE POOL WALL. REFER
COL TO ENGINEERS DRAWINGS FOR DETAILS
G RS1 NEW COLORBOND METAL ROOF
SHEETING AS SELECTED FIXED IN
124200 ACCORDANCE WITH MANUFACTURERS
SPECIFICATIONS
SBR STONE BLOCK RETAINING WALL SHOWN
1 Elevation 3 Elevation INDICATIVE. BUILDER TO CO-ORDINATE
SOF1 FLUSH LINED PROPRIETARY FIBRE
002 SCALE 1 : 100 002 SCALE 1 : 100 CEMENT SHEET SOFFIT
SOF2 FEATURE TIMBER SOFFIT LINING AS
SELECTED
TS PROPRIETARY TIMBER LOOK METAL
BATTEN SCREEN
WT1 WALL TYPE 1 - PROPRIETARY FC
FACADE AS SELECTED EXTERNALLY
600 600 90mm TIMBER STUD FRAMING +
131452 RS1 BC PLASTERBOARD LINED INTERNALLY FC
131162
SHEETING & WATERPROOFING TO WET
SOF2 AREAS WHERE REQUIRED
0650 P1
WT1 P1 P1 R1
2 SOF1 LVR P1 LVR 0670
129850
FG FG COL FG COL
2470 SD BLK1
2650
1920 2435 2435 2427 2411 COL
2450 HR-A
LVR FG
COL TS
1 FG FG FG LVR FG FG LVR FG FG
127200 WT1
CN1
3000
BLK1
COL BLK1 BLK1 COL
R1 RCPW 2142 SD
R1 R1 CN1
P2 CN1
HC
G
124200
2 Elevation Rev Description Date
002 SCALE 1 : 100 1 ISSUED FOR CONSTRUCTION 24.07.22
2 GENERAL AMENDMENTS 20.10.22
D AVIES BUILDING DESIGN
[email protected]
T: 61 (0)424631704
QBCC 15022755
RESI DENTI AL
600 600
I N D U ST R I AL
EG-R BC C O M M E R C I AL
P1 RS1 EG
BC P1
2 P1 EG EG drawing title
ELEVATIONS
129850
R1 P1
R1 0606 1506 WT1
2650
COL BLK1 BLK1 BLK1 SBR
LVR LVR P1
TS
1524 1524
820 R1 address
HC LOT 8 HINTERLAND CL.
1 DP
DP DP DP DP TINBEERWAH
127200
project title
PROPOSED RESIDENCE FOR
4 Elevation L & S HILL
002 SCALE 1 : 100
project # scale at a3 Drawn
NOOSA COUNCIL Contractors to use Architectural drawings for set out.
Contractors to check and verify all Dimensions on Site prior 040 1 : 100 MD
APPROVED PLAN toConstruction/Fabrication. Figured Dimensions take precedence
over Scaled Dimensions. Any discrepancies should be immediately drawing # rev.
MCU22/0133 11 NOV 2022 003 2
referred to the Architect. All work to comply with N.C.C.
Statutory Authorities and relevant Australian Standards.