Original source · versioned page text
Appendix B - New Dwelling Plans
Plans and drawings: the text below has words only, no drawings.
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
ELECTRICAL LEGEND:
SYMBOL DESCRIPTION
NOTES:
SWITCHBOARD/METER BOX
80 PERCENT ENERGY EFFICIENT GLOBES TO ALL FIXED INTERNAL LIGHTING.
DISTRIBUTION BOARD
MINIMUM 4 STAR 'MEPS' RATED AIR CONDITIONERS WHERE FITTED. SINGLE POWER POINT - 300 above FFL
SYMBOLS ARE INDICATIVE ONLY. DOUBLE POWER POINT - 300 above FFL
EXACT MODEL TO BUILDER'S SPECS. dp SINGLE POWER POINT - 1200 above FFL (UNO)
dp DOUBLE POWER POINT - 1200 above FFL UNO)
MECHANICAL VENTILATION TO BE IN ACCORD.
WITH THE NCC VOL 2, 3.8.5 & AS 1668.2 EX WEATHERPROOF POWER POINT
(DISCHARGE TO EXTERNAL AIR) FLUORESCENT CEILING BATTEN
LED LIGHT FITTING (ROUND)
PHOTOELECTRIC SMOKE ALARM TO NCC VOL 2, 3.7.5 & AS 3786
(MAINS POWERED & INTERCONNECTED) LED LIGHT FITTING (SQUARE)
FEATURE PENDANT
WALL MOUNTED LIGHT FITTING
RECESSED DOWN LIGHT
LEGEND:
LIGHT FITTING - FEATURE RAIL
DW DISHWASHER LIGHT SWITCH - 1000 above FFL (UNO)
PH PHONE
TV TELEVISION LIGHT SWITCH WITH DIMMER CONTROL
DUCTED
FR FRIDGE dp 2-WAY LIGHT SWITCH
HWS dp AC dp
RH RANGEHOOD
ISOLATION SW. FOR HARD WIRED FIXTURE
EX EXTERNAL
A/C AIR CONDITIONER PH TELEPHONE POINT
HW HOTWATER TV TELEVISION POINT
MH MANHOLE
CEILING FAN - ∅1200mm - MINIMUM
PLD PANEL LIFT DOOR WM
ANT ANTENNA
CEILING FAN - ∅1200mm - MINIMUM
dp WITH FLUORESCENT LIGHT
S SMOKE ALARM - HARD WIRED
A/C AIR CONDITIONER UNIT
HW HOT WATER UNIT (storage)
FR HW HOT WATER UNIT (gas)
PLD PLD
WIRING
FAN, LIGHT COMBINATION
FAN, HEAT, LIGHT COMBINATION
DW LIGHT SENSOR
TWIN SPOT LIGHT
RH
dp NO. ITEM
12 DOWNLIGHT - EXTERNAL - LED
MW
50 DOWNLIGHT - INTERNAL - LED
dp
1 FAN LIGHT
2 FLURO BATTENS - INTERNAL
dp 29 POWER POINT - DOUBLE - INTERNAL
7 POWER POINT - SINGLE - INTERNAL
PH 1 TELEPHONE POINT
2 TELEVISION POINT
7 CEILING FAN
4 SMOKE ALARM
dp
dp
TV TV
HWS
dp
dp
dp
dp
dp dp
© COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.
PAGE: SHEET SIZE: REV DRN CHK DETAILS DATE: I/WE HAVE CHECKED THE PLANS AND AGREE THAT
MONTVILLE 462 ASPECT HOUSE
CLIENT: PROJECT: PROPOSED RESIDENCE Supp-1 A2 * RW RW CONCEPT FLOOR PLAN 28/06/22 THEY ACCURATELY DEPICT THE HOUSE FOR
ELECTRICAL PLAN SANDRA & RICHARD MATHISON JOB NUMBER: B AMENDED CONCEPTS 03/08/22
CONSTRUCTION.
(MODIFIED) PLANS LOT 2 ON RP196994 GJGG430718 C
RW
RW
RW
RW AMENDMENTS - PRELIMS 29/09/22 JOB SPECIFICATION BY BUILDER TAKES
1 : 100 1073 POMONA - KIN KIN ROAD SALESPERSON: PRECEDENCE OVER THESE PLANS.
WOJTEK STAINWALD RESORT FACADE DRAWING TITLE:
D RW RW AMENDMENTS - PRELIMS 01/11/22
QLD QLD KIN KIN, QLD CHRIS McNEIL E RW RW AMENDMENTS - PRELIMS 21/12/22 OWNER SIGNED: ............................... DATE: ..........
© COPYRIGHT EXCLUSIVE DATE: F RW RW CONSTRUCTION DRAWINGS 04/05/23 OWNER SIGNED: ............................... DATE: ..........
QBCC 1285235 TO G.J.GARDNER HOMES QBCC 1257937 ELECTRICAL PLAN 13/07/2023 G RW RW GARAGE BIGGER 13/07/23 BUILDER SIGNED: ............................. DATE: ..........
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file