   AS 3959-2018 CONSTRUCTION OF BUILDINGS IN BUSHFIRE PRONE AREAS
   SECTION 5 CONSTRUCTION FOR BUSHFIRE ATTACK LEVEL 12.5 (BAL-12.5)
   5.2 SUBFLOOR SUPPORTS                                                                        5.5 EXTERNAL GLAZED ELEMENTS AND ASSEMBLIES AND EXTERNAL
   Not applicable to the principal building only, not to verandas, decks, steps, ramps          DOORS
   and landings (see Clause 5.7).                                                               5.5.1 BUSHFIRE SHUTTERS                                                                   5.5.5 DOORS - SLIDING DOORS
                                                                                                Where fitted, bushfire shutters shall comply with Clause 3.7 and be made from -           Sliding doors shall—
   5.3 FLOORS                                                                                   (a) non-combustible material; or                                                          (a) be completely protected by a bushfire shutter that conforms with Clause 3.7 and
                                                                                                (b) a timber species as specified in Paragraph E1, Appendix E; or                         Clause 5.5.1; or
   5.3.1 CONCRETE SLABS ON GROUND                                                               (c) bushfire-resisting timber (see Appendix F); or                                        (b) be completely protected externally by screens that conform with Clause 3.6 and
   Not applicable for concrete slabs on ground.                                                 (d) a combination of any of Items (a), (b), or (c) above.                                 Clause 5.5.2; or
                                                                                                                                                                                          (c) conform with the following:
   5.3.2 ELEVATED FLOORS                                                                        5.5.2 SCREENS FOR WINDOWS AND DOORS                                                       (i) Frame material The material for door frames, including fully framed glazed
   Not applicable for elevated floors, including bearers, joists and flooring.                  Where fitted, screens for windows and doors shall have a mesh or perforated sheet         doors, shall be—
                                                                                                made of corrosion-resistant steel, bronze or aluminium. The frame supporting the mesh     (A) bushfire-resisting timber (see Appendix F); or
   5.3.2.1 ENCLOSED SUBFLOOR SPACE                                                              or perforated sheet shall be made from -                                                  (B) a timber species as specified in Paragraph E2, Appendix E; or
                                                                                                (a) metal; or                                                                             (C) metal; or
   Not applicable for elevated floors, including bearers, joists and flooring, where the
                                                                                                (b) bushfire-resisting timber (see Appendix F); or                                        (D) metal-reinforced uPVC and the reinforcing members shall be made from
   subfloor space is enclosed with -
                                                                                                (c) a timber species as specified in Paragraph E2, Appendix E.                            aluminium, stainless steel, or corrosion-resistant setel.
   (a) a wall that confroms with Clause 5.4; or
                                                                                                                                                                                          (ii) Hardware There are no specific requirements for hardware at this BAL level.
   (b) a mesh or perforated sheet with a maximum aperture of 2mm, made of corrosion-            5.5.3 WINDOWS AND SIDELIGHTS                                                              (iii) Glazing Where doors incorporate glazing, the glazing shall be grade A safety glass
   resistant steel, bronze or aluminium; or
                                                                                                Window assemblies shall:                                                                  a minimum of 4 mm in thickness.
   (c) a combination of items (a) and (b) above.
                                                                                                (a) Be completely protected by a bushfire shutter that conforms with Clause 3.7 and       (iv) Seals and weather strips Therea re no specific requirements for seals and
                                                                                                Clause 5.5.1; or                                                                          weather strips at this BAL level
   5.3.2.2 UNENCLOSED SUBFLOOR SPACE                                                                                                                                                      (v) Screens There is no requirement to screen the openable part of the sliding door at
                                                                                                (b) Be completely protected externally by screens that conform with Clause 3.6 and
   Where the subfloor space is unenclosed, the bearers, joists and flooring, less than 400      Clause 5.5.2; or                                                                          this BAL level.
   mm above finished ground level, shall be one of the following:                               (c) Conform with the following:                                                           (vi) Sliding panels Sliding panels shall be tight-fitting in the frames.
   (a) Materials that comply with the following:                                                  (i) Frame material For window assemblies less than 400 mm from the ground or less
     (i) Bearers and joists shall be-                                                           than 400 mm above decks, carport roofs, awnings and similar elements or fittings          5.5.6 DOORS - VEHICLE ACCESS DOORS
       (A) non-combustible; or                                                                  having an angle less than 18 degrees to the horizontal and extending more than 110
       (B) bushfire-resisting timber (see Appendix F); or                                       mm in width from the window frame (see Figure D3, Appendix D), window frames and          The following applies to vehicle access doors:
       (C) a combination of Items (A) and (B) above.                                            window joinery shall be made from one of the following:                                   (a) The lower portion of a vehicle access door that is within 400 mm of the ground
     (ii) Flooring shall be-                                                                    (A) Bushfire-resisting timber (see Appendix F); or                                        when the door is closed (see Figure D4, Appendix D) shall be made from-
       (A) non-combustible; or                                                                  (B) A timber species as specified in Paragraph E2, Appendix E; or                         (i) non-combustible material; or
       (B) bushfire-resisting timber (see Appendix F); or                                       (C) Metal; or                                                                             (ii) bushfire-resisting timber (see Appendix F); or
       (C) timber (other than bushfire-resisting timber), particleboard or plywood flooring     (D) Metal-reinforced uPVC. The reinforcing members shall be made from aluminium,          (iii) fibre-cement sheet a minimum of 6 mm in thickness; or
   where the underside is lined with sarking-type material or mineral wool insulation; or       stainless steel, or corrosion-resistant steel.                                            (iv) a timber species as specified in Paragraph E1, Appendix E; or
       (D) a combination of any of Items (A), (B) or (C) above. or                                (ii) Hardware There are no specific restrictions on hardware for windows.               (v) a combination of any of Items (i), (ii), (iii) or (iv).
   (b) A system complying with AS 1530.8.1                                                        (iii) Glazing Where glazing is less than 400 mm from the ground or less than 400 mm     (b) All vehicle access doors shall be protected with suitable weather strips, draught
   The Standard does not provide construction requirements for elements of elevated             above decks, carport roofs, awnings and similar elements or fittings, having an angle     excluders, draught seals or brushes. Door assemblies fitted with guide tracks do not
   floors, including bearers, joists and flooring, if the underside of the element is 400 mm    less than 18 degrees to the horizontal and extending more than 110 mm in width from       need edge gap protection.
   or more above finished ground level.                                                         the window frame (see Figure D3, Appendix D), the glazing shall be toughened glass        NOTES:
                                                                                                minimum 5 mm in thickness, or glass blocks with no restriction on glazing ethods.         1 Refer to AS/NZS 4505 for door types.
                                                                                                NOTE: Where double-glazed units are used, the requirements apply to the external          2 Gaps of door edges or building elements should be protected as per Section 3.
   5.4 EXTERNAL WALLS                                                                           pane of the glazed assembly only. For all other glazing, annealed glass may be used
   5.4.1 WALLS                                                                                  in accordance with AS1288.                                                                C5.5.6(b) These guide tracks do not provide a direct passage for embers into the
                                                                                                  (iv) Seals and weather strips There are no specific requirments for seals and weather   building.
   The exposed components of an external wall that are less than 400 mm from the                                                                                                          (c) Vehicle access doors with ventilation slots shall be protected in accordance with
                                                                                                stips at this BAL level.
   ground or less than 400 mm above decks, carport roofs, awnings and similar elements                                                                                                    Clause 3.6.
                                                                                                  (v) Screens The openable portions of windows shall be screened internally or
   or fittings having an angle less than 18 degrees to the horizontal and extending more
                                                                                                externally with screens that conform with Clause 3.6 and Clause 5.5.2
   than 110 mm in width from the wall (see Figure D3, Appendix D) shall be:
   (a) Non-combustible material.
   NOTE: Examples include, but are not limited to, the following (with a minimum of 90          5.5.4 DOORS - SIDE HUNG EXTERNAL DOORS
   mm in thickness):
                                                                                                Side-hung external doors, including French doors, panel fold and bi-fold doors, shall-
     (i) Full masonry or masonry veneer walls with an outer leaf of clay, concrete, calcium     (a) be completely protected by bushfire shutters that conform with Clause 3.7 and
   silicate or natural stone.                                                                   Clause 5.5.1; or
     (ii) Precast or in situ walls of concrete or aerated concrete.
                                                                                                (b) be completely protected externally by screens that conform with Clause 3.6 and
     (iii) Earth wall including mud brick; or
                                                                                                Clause 5.5.2; or
   (b) Timber logs of a species with a density of 680 kg/m3 or greater at a 12 percent          (c) conform with the following:
   moisture content; of a minimum nominal overall thickness of 90 mm and a minimum                (i) Door panel material Materials shall be-
   thickness of 70 mm (see Clause 3.11); and gauge planed; or
                                                                                                (A) non-combustible; or
   (c) Cladding that is fixed externally to a timber-framed or a steel-framed wall and is-
                                                                                                (B) solid timber, laminated timber or reconstituted timber, having a minimum
     (i) non-combustible material; or
                                                                                                thickness of 35 mm for the first 400 mm above the threshold; or
     (ii) fibre-cement a minimum of 6 mm in thickness; or                                       (C) hollow core, solid timber, laminated timber or reconstituted timber with a
     (iii) bushfire-resisting timber (see Appendix F); or
                                                                                                non-combustible kickplate on the outside for the first 400 mm above the
     (iv) a timber species as specified in Paragraph E1, Appendix E; or
                                                                                                threshold; or
     (v) a combination of any of Items (i), (ii), (iii) or (iv) above; or
                                                                                                (D) hollow core, solid timber, laminated timber or reconstituted timber
     (d) a combination of any of Items (a), (b) or (c) above.                                   protected externally by a screen that conforms with Clause 5.5.2; or
   The Standard does not provide construction requirements for the exposed                      (E) for fully framed glazed door panels, the framing shall be made from metal
   components of an external wall that are 400 mm or more from the ground or 400 mm
                                                                                                or bushfire resisting timber (see Appendix F) or a timber species as
   or more above decks, carport roofs, awnings and similar elements or fittings having
                                                                                                specified in Paragraph E2, Appendix E or uPVC.
   an angle less than 18 degrees to the horizontal and extending more than 110 mm in              (ii) Door frame material Door frame materials shall be-
   width from the wall (see Figure D3, Appendix D).                                             (A) bushfire resisting timber (see Appendix F); or
                                                                                                (B) a timber species as specified in Paragraph E2 of Appendix E; or
                                                                                                (C) metal; or
                                                                                                                                                                                                                                                                                                     NOTES:
   5.4.2 JOINTS                                                                                 (D) metal-reinforced uPVC. The reinforcing members shall be made from                                                                                                                                TO BE READ IN CONJUNCTION
   All joints in the external surface material of walls shall be covered, sealed, overlapped,   aluminium, stainless steel, or corrosion-resistant steel.
   backed or butt-jointed.                                                                        (iii) Hardware There are no specific requirements for hardware at this BAL level.                                                                                                                  WITH AS 3959-2018
                                                                                                  (iv) Glazing the glazing shall be Grade A safety glass a minimum of 4 mm in
   5.4.3 VENTS AND WEEPHOLES                                                                    thickness, or glass blocks with no restriction on glazing methods.
                                                                                                NOTE: Where double glazed units are used the above requirements apply to the                                                                                                                         SEE AS3959-2018 APPENDIX D FOR
   Except for exclusions provided in Clause 3.6, vents and weepholes in external walls          external face of the window assembly only.
   shall be screened with a mesh made of corrosion-resistant steel, bronze or aluminium.          (v) Seals and weather strips Weather strips, draft excluders or draft seals shall be
                                                                                                                                                                                                                                                                                                     DIAGRAMATIC DETAILS IF
                                                                                                installed.                                                                                                                                                                                           REQUIRED
                                                                                                  (vi) Screens There are no requirements to screen the openable part of the door at
                                                                                                this BAL level.
                                                                                                  (vii) Doors shall be tight-fitting to the door frame and to an abutting door, if
                                                                                                applicable.



© COPYRIGHT. THIS DRAWING REMAINS THE PROPERTY OF G.J GARDNER HOMES & IS PROVIDED FOR THE USE AS DESCRIBED & MAY NOT BE USED OR REPRODUCED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. ANY LANDSCAPING (WHEN SHOWN) ARE FOR ILLUSTRATIVE PURPOSES ONLY AND DO NOT FORM PART OF ANY CONTRACT.
                                                                                                                                                                                                                           PAGE: SHEET SIZE: REV DRN CHK DETAILS                        DATE: I/WE HAVE CHECKED THE PLANS AND AGREE THAT
                                                                  MONTVILLE 462                           ASPECT HOUSE
                                                                                                                                              CLIENT:                                       PROJECT: PROPOSED RESIDENCE                          Supp-Y       A3       *   RW     RW CONCEPT FLOOR PLAN        28/06/22   THEY ACCURATELY DEPICT THE HOUSE FOR
                                                                                                                                                                                                                                                                                                                          CONSTRUCTION.
                                                                                                                                              SANDRA & RICHARD MATHISON                                                                          JOB NUMBER:           B   RW     RW AMENDED CONCEPTS          03/08/22
                                                                   (MODIFIED)                                PLANS                                                                          LOT 2 ON RP196994                                    GJGG430718            C   RW     RW AMENDMENTS - PRELIMS      29/09/22   JOB SPECIFICATION BY BUILDER TAKES
                                                                                                                                                                                                                                                                                                                          PRECEDENCE OVER THESE PLANS.
         WOJTEK STAINWALD                                                 RESORT FACADE                                                                                                     1073 POMONA - KIN KIN ROAD                           SALESPERSON:          D   RW     RW AMENDMENTS - PRELIMS      01/11/22
                                                                                                                                              DRAWING TITLE:
               QLD                                                                                             QLD                                                                          KIN KIN, QLD                                         CHRIS McNEIL          E   RW     RW AMENDMENTS - PRELIMS      21/12/22   OWNER SIGNED: ............................... DATE: ..........
                                                                     © COPYRIGHT EXCLUSIVE                                                                                                                                                       DATE:                 F   RW     RW CONSTRUCTION DRAWINGS     04/05/23   OWNER SIGNED: ............................... DATE: ..........
           QBCC 1285235                                              TO G.J.GARDNER HOMES                   QBCC 1257937                      BUSHFIRE NOTES 1 (BAL 12.5)                                                                        13/07/2023            G   RW     RW GARAGE BIGGER             13/07/23   BUILDER SIGNED: .............................   DATE: ..........
Log in to download the original file

Appendix B - New Dwelling Plans.pdf · 2.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.