   expected fireline intensity and Radiant                                   o.5 degrees, for the slope value. These
   heat flux exposure for unit 1.                                            values, however, add an additional
4. It must be noted that the Calculator                                      conservative safety margin onto the
   uses an excessive flame temperature of                                    potential actual radiant heat flux
   1,200k with the default in AS3959 being                                   exposure of the structure and potential
   1,080k and cannot use a point value i.e.                                  fireline intensity values.
Table 1 – SPP Bushfire Asset Protection Zone Width Calculation

                 SPP Bushfire Asset Protection Zone Width Calculator
VARIABLE DESCRIPTION                              VARIABLE UNITS                                                      VALUE
                                     Input Values
FIRE WEATHER SEVERITY                                                              FDI                               48.00
VEGETATION HAZARD CLASS                                                            VHC                          34.5 Sedgeland
                                                                                                                  dominated
                                                                                                    -              wetlands
REMNANT STATUS                                                                      -               -              Remnant
SLOPE TYPE (UPSLOPE OR DOWNSLOPE)                                                  ST               -              Upslope
EFFECTIVE SLOPE UNDER THE HAZARDOUS VEGETATION                                   eSlope          degrees             1.00
SLOPE BETWEEN SITE AND HAZARDOUS VEGETATION                                         θ            degrees             1.00
DISTANCE OF THE SITE FROM HAZARDOUS VEGETATION                                      d              m                 20.00
                                                         Output Values
SURFACE FUEL LOAD                                                                    -             t/ha                 3.00
NEAR SURFACE FUEL LOAD                                                               -             t/ha                 5.00
BARK FUEL LOAD                                                                       -             t/ha                 5.00
ELEVATED FUEL LOAD                                                                   -             t/ha                 0.00
TOTAL OVERALL FUEL LOAD                                                              W             t/ha                13.00
TOTAL SURFACE FUEL LOAD                                                              w             t/ha                 8.00
POTENTIAL FIRE LINE INTENSITY                                                        I            kW/m                 18997
RADIANT HEAT FLUX                                                                    q           kW/m2                 16.50
BUSHFIRE ATTACK LEVEL (AS 3959-2018)                                               BAL             -                  BAL 19
DISCLAIMER: Fire-line intensity and radiant heat calculations where effective slope exceeds 20 degrees (downslope) or 15 degrees
(upslope) may be unreliable. In these locations, specialist assessment is warranted.



Conclusions                                                                  greater than 50 metres and less than
                                                                             100 metres, and/or
Based on the above discussion the                                         c. The structure and species
following conclusions have been made: -                                      dominance in the groundcover and
                                                                             understorey within surrounding
1. The bushfire hazard mapping over and                                      patches, and
   within 100 metres of the development                                   d. With respect to the development
   site can be reduced to low bushfire                                       footprint, the bushfire hazard will be
   hazard based on the status of;                                            removed and managed into the
   a. The patch size, and/or                                                 future as a natural consequence of
   b. The lack of connectivity of                                            the development approval.
       continuous fuels with a width of                                2. This includes the corridor of vegetation
                                                                          between Weyba Creek and the western
                                                                          boundary of the proposed development.
    RFA18-048 – 22 - RACV NOOSA RESORT – ECO-CABINS - BUSHFIRE HAZARD ASSESSMENT AND MITIGATION PLAN
ROB FRIEND & ASSOCIATES PTY LTD                                                                                       17 JUNE 2022

Used in these records

About this file

File size
7.6 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 6 - Bushfire Hazard Assessment.pdf · 7.6 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.