If the following parameter values are input into the formula:
t = 22;
K = 0.12 (representative)
I = 0.025 (1:40);
= 0.2;
an indicative setback distance (D) of less than one metre results. This is less than
the 10 metres horizontal setback distance adopted. Further, there are no dams, and/or
watercourses within 10 metres from the proposed effluent land application area
5 Conclusion
5.1 Soil absorption properties and site features are adequate for on-site effluent disposal
provided the recommendations made herein are followed and/or amended by a
licensed plumber or suitably qualified-system designer.
5.2 The homeowner should fully inform themselves about the on-site wastewater system
on their property and its operation and maintenance. The supplier and/or installer
of the treatment system will supply their operation and maintenance guideline.
5.3 Attached as APPENDIX B is a generic operation and maintenance guideline relevant
to secondary and advanced secondary effluent qualities.