1890 Effluent Disposal Review · MCU20/0022
Recommended horizontal separation distances for protection of water quality
Recommended
Feature
Horizontal Separation
• Top of bank of permanent water course; Distance
• Top of bank of Intermittent water course;
“Modified” Advanced
• Top of bank of a lake;
Secondary effluent: 10 metres
• Top water level of a surface water source used for agriculture,
(horizontal)
aquaculture or stock purposes;
• Easement boundary of unlined open stormwater drainage
channel or drain.
“Modified” Advanced
Bore or a dam used or likely to be used for human and/or
Secondary effluent: 10 metres
domestic consumption.
(horizontal)
“Modified” Advanced
Unsaturated soil depth to a permanent water table. Secondary effluent: 0.3
metres (vertical)
Notes:
The separation distances are recommended and the local government may upon considering the
public health and environmental risks reduce or increase the distances given.
4 Design Consideration
4.1 Design Parameters (Residence)
The “design” soil category is based on 5 – light clay.
The inferred design-loading rate (DIR) for these soil types is 3mm/day
Wastewater flow allowance for the residence is 120 litres/person/day
For a five-bedroom residence, we have allowed for 7 persons
A spa bath is not proposed
Total loading = 840 litres/day
4.2 Calculated Irrigation Area
For a design irrigation rate (DIR) of 3mm /day, this results in an irrigation area of
280m2.
4.3 Noosa Council require a minimum 9 fixed sprinklers per 100m² of effluent application
area. We propose twenty-five (25) fixed sprinklers.
Page 6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
1890 Effluent Disposal Review.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.