4.8   Proposed System: (Residence)
      The client proposes to dispose of the effluent to the north and northwest of the
      residential area, established as a linear projection along the driveway and across the
      northern face of the residence.
      The system will consist of the following:
       The application areas will be established as a mulched and shrubs can be
         established at each outlet.
         A typical layout is shown on PLATE 4.
         A 25mm diameter delivery line (purple stripe of flagged) from the treatment system.
          The line is to be buried.
         25 fixed sprinklers (wobblers or rota-frame) are to be established on a 300mm hard
          riser and configured as 5 X 5 sprinklers and sequential lateral dosing by a 6-port
          indexing valve.
         The sprinklers are to be 3 metres apart, 3 metres from the driveway and 10 metres
          from the residence.
         The indexing valve should be adjacent the highest contour of the application area.
         With a 1.0 throw allowance (AS 1547, M 9.4.3/e) effluent is excluded from within 3
          metres of the driveway, property boundary and with 10 metres of the residence.
         Mulch is to be placed within a 1.0 metres radius of each sprinkler outlet.


4.9   Proposed System: (Cottages)
      The client proposes to dispose of the effluent to the centrally and to the east/ southeast.
      The system will consist of the following:
       The application areas will be established as a mulched and shrubs can be
         established at each outlet.
         A typical layout is shown on PLATE 5.
         A 25mm diameter delivery line (purple stripe of flagged) from the treatment system.
          The line is to be buried.
         30 fixed sprinklers (wobblers or rota-frame) are to be established on a 300mm hard
          riser and configured as 6 X 5 sprinklers and sequential lateral dosing by a 6-port
          indexing valve.
         The sprinklers are to be 3 metres apart, 3 metres from the driveway and laterals 10
          metres from a cottage.
         The indexing valve should be adjacent the highest contour of the application area.
         With a 1.0 throw allowance (AS 1547, M 9.4.3/e) effluent is excluded from within 3
          metres of the driveway, property boundary and with 10 metres of the residence.
         Mulch is to be placed within a 1.0 metres radius of each sprinkler outlet.
         The treatment plant electronic box must be above the Q100 flood contour.




                                                                                           Page 8

Used in these records

About this file

File size
9.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

1890 Effluent Disposal Review.pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.