Council archive · source document
1890 Effluent Disposal Review · MCU20/0022
4.8 Proposed System: (Residence)
The client proposes to dispose of the effluent to the north and northwest of the
residential area, established as a linear projection along the driveway and across the
northern face of the residence.
The system will consist of the following:
The application areas will be established as a mulched and shrubs can be
established at each outlet.
A typical layout is shown on PLATE 4.
A 25mm diameter delivery line (purple stripe of flagged) from the treatment system.
The line is to be buried.
25 fixed sprinklers (wobblers or rota-frame) are to be established on a 300mm hard
riser and configured as 5 X 5 sprinklers and sequential lateral dosing by a 6-port
indexing valve.
The sprinklers are to be 3 metres apart, 3 metres from the driveway and 10 metres
from the residence.
The indexing valve should be adjacent the highest contour of the application area.
With a 1.0 throw allowance (AS 1547, M 9.4.3/e) effluent is excluded from within 3
metres of the driveway, property boundary and with 10 metres of the residence.
Mulch is to be placed within a 1.0 metres radius of each sprinkler outlet.
4.9 Proposed System: (Cottages)
The client proposes to dispose of the effluent to the centrally and to the east/ southeast.
The system will consist of the following:
The application areas will be established as a mulched and shrubs can be
established at each outlet.
A typical layout is shown on PLATE 5.
A 25mm diameter delivery line (purple stripe of flagged) from the treatment system.
The line is to be buried.
30 fixed sprinklers (wobblers or rota-frame) are to be established on a 300mm hard
riser and configured as 6 X 5 sprinklers and sequential lateral dosing by a 6-port
indexing valve.
The sprinklers are to be 3 metres apart, 3 metres from the driveway and laterals 10
metres from a cottage.
The indexing valve should be adjacent the highest contour of the application area.
With a 1.0 throw allowance (AS 1547, M 9.4.3/e) effluent is excluded from within 3
metres of the driveway, property boundary and with 10 metres of the residence.
Mulch is to be placed within a 1.0 metres radius of each sprinkler outlet.
The treatment plant electronic box must be above the Q100 flood contour.
Page 8
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
1890 Effluent Disposal Review.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.