Council archive · source document
Architecturals - pt6 · 132005.1133.7
Attached to the e-mail Change Application - 132005.1133.7 (4 of 6).
Very large file (11.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 14, section 1. The text section number identifies this passage in the reader.
1501 1502 1503 1504 1505 1506
8340 7800 7800 7800 8340
A B
05-10 05-10
03
07-03
BG DP (RO) DP (RO) BG
15A 15A
LINE OF WALL BELOW
EC
02 SELECTED
WATERPROOFING
3960
07-04 5˚
MEMBRANE TO LIFT FL EC
SHAFT CONCRETE FALL
SLAB
5˚ DP (RO) BG BG DP (RO) 5˚
06 FALL FALL FALL
07-05
15B EC EC 15B
FL FL
RC
5˚ VG VG 5˚
EC FL EC FALL FALL FL EC FL EC EC
5˚ 5˚
FALL FALL
04
07-03 EC EC EC
6115
05
07-05
15C 15C
KLIP-LOK COLORBOND
KLIP-LOK COLORBOND ROOF ROOF SHEETING.
SHEETING. INSTALLED TO INSTALLED TO
MANUFACTURERS SPECIFICATION MANUFACTURERS
SPECIFICATION
EC EC
8200
C C
05-11 3.5˚ FALL 3.5˚ FALL 3.5˚ FALL 05-11
04
07-03
C
05-16
15D 15D
DASHED LINE OF
FLOOR BELOW
5440
15E 15E
DP (RO) DP (RO) DP (RO) DP (RO) DP (RO) DP (RO) DP (RO) DP (RO)
BG
05
07-03
1501 1502 1503 1504 1505 1506
A B
05-10 05-10
ROOF PLAN LEGEND
AIR CONDITIONER CONDENSOR
BG BOX GUTTER
DP DOWNPIPE
EC EDGE CAPPING
FL FLASHING
GF GUTTER FALL
GFL GAS FLUE
01 ROOF PLAN MEF
RC
MECHANICAL EXHAUST FAN
RIDGE CAPPING
- BLOCK 15 SCALE 1:100 RO ROOF DRAIN OUTLET
SL SKYLIGHT
SP SPREADER
VG VALLEY GUTTER
VP VENT PIPE
NOTE : REFER TO HYDRAULIC ENGINEER'S DRAWINGS FOR
GUTTER AND DP SIZES
BUILDING APPROVAL
NOT FOR CONSTRUCTION
CHECKED : .............................................
notes : issue amendment log by date issue amendment log by date project: north
A BUILDING APPROVAL KU 02-08-17
date: MAY 2017
1 The designs, drawings and specification are B BUILDING APPROVAL KU 18-08-17 PROPOSED PRECINCT F DEVELOPMENT,
copyright and always remain the property of C REVISED ISSUE KU 04-09-17 NOOSA SPRINGS drawn: AP
Blackburne Jackson Design Pty Ltd.
B la ck b u rn e J a ck s o n D e s i gn
-
checked: RJ
2 Before commencing construction: Archi tec t ure Landscape I n t e r i or s client:
- Verify all dimensions and levels.
- Verify location and levels of all services on site. ALTUM CONSTRUCTIONS scale: 1:100
- Verify that floor levels and finished levels will 37 Aerodrome Rd Maroochydore Qld title:
enable connection to services. project/drawing no.
P.O. Box 154 Cotton Tree Qld 4558
email [email protected]
phone
fax
07 5443 3200
07 5443 4030
BLOCK 15 ROOF - FLOOR sheet: A1
3 Do not scale this drawing.
When in doubt refer to Architects. PLAN 7088_A02-34_C
7088-18-CTS 1 printed: Tuesday, 3 October 2017 9:22 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Architecturals - pt6.pdfRelated documentApplication case desk ↗
About this file
- File size
- 11.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.