Council archive · source document
Architecturals - pt6 · 132005.1133.7
Attached to the e-mail Change Application - 132005.1133.7 (4 of 6).
Very large file (11.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 32, section 1. The text section number identifies this passage in the reader.
301 302 303 304 305
9140 7800 7800 5850
04 EC
10-03
07-02
02
EC EC EC
EC EC
3A 3A
CONTINUES ON DRAWING 7038_A02-124
5040
3B 3B
04
04 5˚ 5˚ 04 10-03
8300 10-03
FALL FALL 10-03
COLORBOND KLIP-LOK
ROOF SHEETING
INSTALLED TO
MANUFACTURERS
SPECIFICATION
EC
EC EC
4340
5˚ FALL 5˚ FALL
VG VG
02 RC
07-03 FL FL
BG BG
3D 3D
BG RO RO BG BG RO RO BG
03
07-02
COLORBOND KLIP-LOK FALL
04
3590
3˚ 3˚
ROOF SHEETING FALL FALL
INSTALLED TO 07-03 5˚ EC EC EC 5˚ EC
FALL COLORBOND KLIP-LOK FL FL FALL
MANUFACTURERS 04
SPECIFICATION ROOF SHEETING INSTALLED
10-03 EC EC TO MANUFACTURERS
SPECIFICATION
EC EC
3E 3E
EC SELECTED WATERPROOFING EC
MEMBRANE TO LIFT SHAFT
CONCRETE SLAB
A B
A05-20 A05-20
301 302 303 304 305 ROOF PLAN LEGEND
AIR CONDITIONER CONDENSOR
BG BOX GUTTER
DP DOWNPIPE
EC EDGE CAPPING
FL FLASHING
GF GUTTER FALL
GFL GAS FLUE
01 ROOF PLAN MEF
RC
MECHANICAL EXHAUST FAN
RIDGE CAPPING
- SCALE 1:100
RO ROOF DRAIN OUTLET
SL SKYLIGHT
SP SPREADER
VG VALLEY GUTTER
VP VENT PIPE
NOTE : REFER TO HYDRAULIC ENGINEER'S DRAWINGS FOR
GUTTER AND DP SIZES
BUILDING APPROVAL
NOT FOR CONSTRUCTION
CHECKED : .............................................
notes : issue amendment log by date issue amendment log by date project: north
A BUILDING APPROVAL KU 02-08-17
date: 2017
1 The designs, drawings and specification are B BUILDING APPROVAL KU 18-08-17 PROPOSED PRECINCT F DEVELOPMENT,
copyright and always remain the property of C REVISED ISSUE MF 03-10-17 NOOSA SPRINGS drawn: CM
Blackburne Jackson Design Pty Ltd.
B la ck b u rn e J a ck s o n D e s i gn checked: SC
2 Before commencing construction: Archi tec t ure Landscape I n t e r i or s client:
- Verify all dimensions and levels.
- Verify location and levels of all services on site. ALTUM CONSTRUCTIONS scale: 1:100
- Verify that floor levels and finished levels will 37 Aerodrome Rd Maroochydore Qld title:
enable connection to services. P.O. Box 154 Cotton Tree Qld 4558 phone 07 5443 3200 project/drawing no. sheet: A1
3 Do not scale this drawing.
When in doubt refer to Architects.
email [email protected] fax 07 5443 4030
BLOCK 3 - ROOF PLAN 7098_A02-05_C
7088-18-CTS 3 printed: Tuesday, 3 October 2017 9:44 AM
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records