Council archive · source document
stage 7 · 51901.3990.02
Attached to the e-mail Change to DA - 51901.3990.02.
NOTES: 11 pacific avenue, sunshine beach 4567 lot 2 on SP185673 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE AUSTRALIAN DOMESTIC BUILDING CODE. 2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL. 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE MGP 10/MGP12 4.HARDWOOD FRAMING TO BE MINIMUM STRESS GRADE F14 & MINIMUM JOINT GROUP J2. 5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4. 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF. SPECIFICATIONS ALL OTHER FIXINGS TO BE IN ACCORDANCE WITH AS 1684.2 2010 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN TABLES WHERE OTHER BRANDS ARE USED, SIZES TO BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS. 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES 9. BUILDER AND TRADES ARE TO CONFIRM ALL MEASUREMENTS, DETAILS AND SPECIFICATIONS PRIOR TO SETOUT AND ORDERING OF MATERIALS 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER AS NO RESPONSIBILITY WILL BE TAKEN AFTER CONSTRUCTION HAS COMMENCED 11. ALL TRADES ARE TO CONFORM WITH THE CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR HER OWN WORK 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS 3660.1.2000 dp DOMESTIC SMOKE ALARMS: dp 1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT REGULATION 2016 2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE WITH AS 20.50° 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL AND INTERCOM 20.50° SYSTEMS. 3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD WIRED dp (EXISTING DWELLINGS ONLY) THAT CANNOT BE REMOVED FROM DEVICE NOTE: SMOKE ALARMS TO BE INSTALLED IN ALL HALLWAYS AND BEDROOMS TO EXISTING RESIDENCE 20.50° 20.50° dp DOWNPIPE LOCATIONS ARE SUGGESTED ONLY ROOF DESIGN AND BUILDER TO CONFIRM roof plan NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC PROPOSED: CLIENT: CAROLYN CRESSWELL PH: 0402 365 423 BUILDER: TBC MANDY'S DESIGN & DRAFTING SHEET: 9 of 9 DATE: ISSUE NO: EXTENSION SUSAN LINDEQUE PH: 0413 887 850 PH: 0403 481 474 SCALE: 1:100 3 JULY 2018 G NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
stage 7.pdfRelated documentApplication case desk ↗
About this file
- File size
- 752 KB (small file)
- File type
No other editions are linked here.