Original source · versioned page text
RFI - S11029-A3-Detail & Level
C(D)
SYMBOLS
Drainage MH Irrigation Valve Camera
E OH
Drainage Pit Water Meter
Tree
Power Pole Unknown MH
Electrical Box Inspection Opening
C(D)
End of Trace
Electrical Pit Comms/Telstra/Optus Pit
TOG12.90
Light Pole/Post Traffic Sign
2 Storey House
E OH
Gas Pit/Valve Advertising Sign
Sewer MH Post
N Fire Hydrant
C(D)
Water Valve
TOG15.52
TOG15.50
RR16.66
11 TREE CODES TREE LEGEND ABBREVIATIONS
E OH
P9313
Height of Tree 10m
Dia. of Trunk 0.2m
FR Fruit Tree TOG Top of Gutter
S(D)
Radial Spread of
NAT Native Tree FL Floor Level
Canopy 3.0m
Type of Tree
C(D)
OR Ornamental Tree RR Roof Ridge
PA Palm IL Invert Level
E OH
PN Pine Tree SL Surface Level
00 00
00
STR 9. 8. STR Street Tree Ø Diameter
12 . 00
.
OR-02 03 10
S(D)
Pathway
10
PA-030204-
11 . 00 NAT-030304 NAT-030407 SURVEY LEGEND RET Retaining Wall
IL11.19
IL6.09
IL11.09 Ø325
C(D)
D(D) D(D) D(D) D(D) D(D)PA-030306- D(D) D(D) D(D) D(D) D(D) D(D) D(D) D(D) D(D) IL6.33 Bottom of Bank
Edge of Bitumen
SL:11.25 S(D) S(D) SL:7.34
E OH
S(D) S(D) Retaining Wall Crown of Road
S(D) S(D) S(D) S(D) S(D) IL6.14
S(D) S(D) S(D) S(D)
IL6.13
Top of Bank Change of Grade
S(D)
270°00'
Fence Edge of Vegetation
33.561
Guard Rail Overhead Elect E OH
C(D)
Unspecified Overhead Comms COH Overhead Unknown UOH
E OH
NAT-020204 Conduit.
Assumed Sewer SUBSURFACE UTILITY LEGEND (Quality Level C demonstrated below)
Street
NAT-030405
House Connection
S(D)
Comms C(C) Electricity E(C)
Optic Fibre COF(C) Elect HV E HV (C)
CT (C)
C(D)
Telstra Elect LV E LV (C)
F(C) Petroleum P(C)
E OH
Fire Services
Gas G(C) Recycled Water R(C)
10
182°13'20" S(D)
Gas Low Press GL (C) Unknown U(C)
P9313 21
Gas High Press GH (C) Water W(C)
182°13'20"
C(D)
Drainage D(C) Irrigation IR(C)
15.083
15.083
AP22965
Plover
E OH
Sewer S(C) Rising Main S RM(C)
NAT-020406
S(D)
Tree scaled from
dts
aerial image only
NAT
urban planning, surveying
C(D)
506m² NAT-040808 & development
E OH
0
8.0
8 . 00
Brisbane & Sunshine Coast
S(D)
PO Box 3128 West End QLD 4101
Ph: 07 3118 0600 Ph: 1300 278 783
[email protected]
C(D)
[email protected]
E OH
ELECTROSCAN
C(D) NAT-030607
EOH
S(D)
E 90°00'
UTILITY LOCATION, MAPPING AND PROTECTION
33.561
Benchmark
Screw in Opposite Kerb C(D)
C(D)
(07) 3118 0650 PO Box 3128, West End 4101
11 . 00
RL12.42 electroscanqld.com.au Level 2, 22 Cordelia Street, South Brisbane, 4101
E OH
12 . 00
Unspecified
10 . 00
9 . 00
Conduit. ELECTROSCAN l ABN 27 010 000 843 I ACN 010 000 843
S(D)
Assumed Sewer
House Connection Revision Description Date
9
0 Original Issue 03/02/2021
P9313
C(D)
E OH
Title Block 1-07-20
0 10 20
Client: Nick & Katie Jorss
C(D)
Scale 1:150 when plotted at A3
Detail and Level Survey
E OH
Notes:
1. Title boundaries were not marked at the time of survey and have been determined from
Disclaimer: CLASSIFICATION OF SUBSURFACE UTILITY INFORMATION (SUI) - AS 5488--2019 34 Plover Street, Peregian
This plan includes information describing the location of Subsurface Utility Information (SUI) features Labeling utility information by a Quality Level allows the user of this information to understand clearly how the information was collected and then place an appropriate amount of reliance on it.
identification survey IS288550. For accurate locations of boundaries, an
that were purported to exist at the time of the survey. This information was compiled from a combination Project risks related to underground utilities can then be properly managed.
Identification survey is recommended.
2. These contours and levels do not represent the natural ground levels as defined by
of field techniques and available data from cooperating utility authorities and third parties. Whilst all care
and consideration has been taken in the preparation of this plan, DTS cannot guarantee that the plan is
Quality Level A: Real Property Description
Cityplan 2014. Information is of the highest possible level of accuracy and is obtained by exposing the underground utility using a non-destructive excavation (potholing) technique. The vertical information for
without flaw of any kind. Therefore DTS expressly disclaims all liability for errors or omissions of
any kind whatsoever or for any loss, damage or other consequences which may arise from relying on
this locating method is to the top or shallowest part of the located service. The 3D location is recorded by survey as an X, Y, Z coordinate.
Quality Level B:
Lot 10 on P9313 Locality Peregian Beach
anything stated on this plan, or in the event that this plan does not cover the site in its entirety
(e.g. private property). It is strongly recommended that users verify the location of SUI features that may
Information is collected by designating the horizontal and vertical location of underground utilities by using Electro Magnetic Induction (EMI). This is the most common form of utility locating and
although an X, Y and Z position can be established it is not always entirely accurate due to differing electromagnetic fields, soil conditions and multiple banks of cables affecting the locating signal.
Datum for Levels PM44289 RL10.963 AHD
or may not be shown on this plan by deploying hydro vacuum excavation services. Quality Level C:
Information is collected by correlating the survey by Ground Penetrating Radar (GPR) and/or visible utility surface features such as marker plates or water hydrants and acquired Surveyor Drawn Date Drawing No.
Dial-Before-You-Dig plans to “draw” a string which shows the approximate position of services. This method does not usually show multiple banks of cables and does not usually show
three dimensional information.
RC RC 03/02/21 S11029-A3
Quality Level D: Project No.
Information is the most basic level of utility locations using information based on a combination of existing Dial-Before-You-Dig plans, other available existing records, cursory site inspections or
Scale Magnet File Revision
anecdotal evidence. SUI shown as Quality Level D should always be treated as an indication of the potential presence of a service only and should not be used for design. 1:150 @ A3 SSC210002 DETAIL & NGL.mjo SSC210002 0
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.