Council archive · source document
0015A77E.001
Text sections not matched to the original PDF pages. See original document to check page numbers.
IV WIEG SL Wels Lot 1 on RP/3068
DRAWINGS
55 ELIZABETH STREET 1740 — GENERAL NOTES & LEGEND
1740-0-1 —_— STORMWATER DRAINAGE OPERATIONAL WORKS
NOOSAVILLE 1740-0-2 _— SEDIMENT & EROSION CONTROL PLAN
FOR
JAVAKA PTY LTD Pollution Control Management Plan (PCMP):
1 To be responsibility of Management
tering devices like leaf eaters
2. To list all in flow fil
C Op’ and SO he .
3 To keep and maintain a log of cleaning
GENERAL NOTES 4. To clean devices including first flush storage tank
Water Supply and Sanitory Drainoge has been designed and shall be constructed in —as to manufactures specification
eccordonce with the Q'ld Standard Sewerage Law, Q'id Standard Water Suppiy Low,
the National Plumbing and Drainage Code AS 3500., alt relevant Australien Standards, —minimum quarterly, but monthly in rainy season
and the requirements of the Local Authority. —after each major rainfall event
These Orawings are diagrammatic only and shall be read in conjunction with alt relevant
Architectural and other consultants drawings ond specifications and other written To inspect and clean tanks minimum once yearly
instructions that may be issued during the course of the contract. 6. To install and maintain pump and fixtures for
Any discrepancies shall be referred to the supervising officer for decision before
proceeding with the work. reuse/watering/irrigation as to manufactures specification
Contractor shail verify all fixture locations, invert levels, surface levels, and
cover to pipes ore correct and obtainable prior to cormmencement of the work.
The exact location of existing, and proposed services, shall be verified with
the relevont Authority, or other trades as applicable.
Fire stop collars to be used on all plastic pipework penetrating fire resistant
construction. re 7,
SANITARY DRAINAGE 0 pt. i oe Ley
[ae
Underground pipework shall be 100 dia. PVC DWV, min grade 1:60 U.N.O. site wy * ee
Suspended Pipework shall be PVC class DWV. ie fae: fe pre
Trade waste pipework to grease trap suspended shall be "Coesprene” or i
HOPE. Underground shall be vitreous clay or HDPE. ” at Lt Aled a) ea
Trade waste pipework to oil separator shall be HDPE, or Vitreous clay with ated coi Se~ con] ahaa Cnt Ty
“Nitrile” rubber rings. rae
CLeanouts or inspection openings brought to surface in paved or concrete gene? Roser i peng
areas, or within buildings to have brass caps. a me PA
STORMWATER DRAINAGE or ra
Underground pipework shall be 100 dio PVC class SW min grade 1:100 U.N.O. Elizabetp S t | 3 ae a igo a io pe
aed
Downpipes shall be 100 Dia PVC class SW. we noes
Rainwater outlets (RWO} and planter outlets (PO) shall be "Gatic Wade” or similar, oy ™pic Tog ieee) 7 i
with membrane clamp where required. we
WATER SUPPLY Ann st of =m. hs ey i
Pipework shall be copper tube type B. UNO. Water supply pipework shatl be 20 dia
U.N.O. Except one fitting only may be 15 dia. max. length 3000 mm. Pl i
Hot water pipework shall lagged. Kae
Hot water recirculoting lines to be insulated with 20mm “Armaflex” or similar. = a = a
Provide tempering valves on hot water to personal hygiene fixtures. 1e¥¢ ayy ¥ CE
Bs
Underground copper pipework shall be "Kemlagged” or otherwise protected. Proposed Site ad >, a a
Underground pipework not under concrete slab may be polypipe class PN20. Sylvia st Mary ad cE mm. C
one size larger than shown.
Exposed pipework in amenities oreas, shall be chrome plated. ar) "Ra Sy:
Where woter meters are installed within tennancies, provide remote readout tie hero ed oy
adjacent to Electrical meters, or in a position os indicated by the Architect. a Ly
BACKFLOW PREVENTION Sibso, NR, s eo e To Fe ee! jj
Provide hose connection vacuum breakers to all hose cocks Rol a Bee hi
Provide RPZD to any irrigation connections. bat
COVERS & FRAMES Kee; ct at oe ia | be
* nw”
Covers subject to vehicular traffic to be 535 dia, cast iron, medium duty UNO. oe aa ot
Covers in grassed or conc. oreas to be 535 dia. cast iron, concrete infill tight duty. eke Load ie
Covers in poved areos to be 600 sq. Infill to match paving pattern.
Covers in tiled areas to be os for paved areas with brass edging. & PF) f rf
Concrete infil! covers to be stamped "SWO" or “SEW’ os appropriate. g et ro
Covers & Frames to be "Faston” or equal approved.
Li
GRATINGS Prone cel
Gratings for storm water to be “faston, Gatic” or approved equal. Ee esta.
Duty to match manufacturers recommendations for loading condition. LOCALITY PLAN Fad Bi 7. ar! 2 a
Trench grate to be transverse bar.
Fioor waste grates to be chrome ptated brass a ¥
LEGEND
Non potable water Diameter
— — Existing water C.0.8. Cleanout to surface Amd: Description
Exi ing sewer CJ Capped junction
Sw Exi ing storm water Cw Conrol valve
———_ HD ——_ Existing house drain cs Cleaners sink
Sanitary Drainage cw Cold Water
Vent Pipe DAP Duct access panel Pe
— ee Coid Water ocVv Double check valve Po
fen Eccentric Enlarger
--—-- Hot water Elev Oge Evevated Drainage
ee een ee wee Storm Water Drainage Enl Enlarger cr Shr
ween ee eee Fire FC False ceiling
agi Agi Drain FH Fire Hydrant Roof water
FHR Fire hose reel
Cold Water Riser FFL Finished floor level L_
FU Fixture units rot -—-— Dishwasher Rainhead with teaf rr
Down Pipe GIT Grease interceptor trap er | So screen and mosquito Dote
Stack GP Gully pit screen if applicable
GMH Gully Man Hoje Sk For Development Approval 11-5-07
Vent Pipe gv Gate valve For Building Approval
HW Hot woter 1
Group vent HCB House connection branch Lu. | L Ley. For Tender
Educt vent HD House drain etn ww aaame. Toe jot For Construction
Induct vent HL High level ee ee a ee Fe ee
Hot water riser Ic Inspection Chamber ijt” TT |As Constructed
Fire Dropper iL Invert Level ee ee ee ee ee ee p epee ro Note: first| flush device Site 540m?
1 Inspection opening Provide mosquito safe
Fire Riser jos Inspection Opening to Surface overflow and inflow screening RPZD | ye Construction Hydraulic
K&C Kerb & Channel
Non potobie riser MH Manhole ea Roof 179m?
—--(M-- water meter NRV Non return vaive — YW Overflow visud| water Driveway 161m? Building Service Engineers
PB Path box -—- level! site tube
PLV Pressure limiting valve Z| Solenoid siphon a opti
onal
v Vaive PO Planter outlet | Heater switchover Landscape 200m?
RPB Real Property Boundary device
he Hose Cock RPD Real Pr. erty description et. >6C floating bail New impervious 340m? contact: Reinhold Koenning Mi€Aust RPEQ No 7023
%
RPZD Reduce ssure Zone device
re:
mane oe een Eccentric enlarger RwO Rain water outtet [He [_] we | Slow leak Detention “ne CATCHMENT AREAS PO Box 1176
en Entarger RWH Rain water head to be determined zone Buddina QLD 4575
SD Sanitary Drainage email: [email protected] PH: 5444 8645
ORG Overflow Relief Gully SL Surface Level Tempering valve Harvesting www.conhyd.com FX: 5444 8224
{jo we Water st Square max SOC Le NP NP. NP NP! nav! cv zone CLIENT :
Sofe Tray
Closet swo Storm water drain mark "NON POTABLE’ JAVAKA PTY LTD
t/td Trapped Tundish
sk Sink TG - Test gate
td Tundish ARCHITECT :
LT Laundry tub t) Trench grate transverse bar
TG NP
TG i) Trench grate longitudinat bor sludge zone water
wm Washin T.M.V, Thermostatic mixing valve Purp Sludge valve | meter Note:
Mochine Tv Tempering voive optional Y=} TOE
FWG Floor Waste u/g Underground D | All kitchen, laundry & bathroom fittings and toilets 55 ELIZABETH STREET
gully u/s Under slab Irrigation z HC to comply with the ASA Water Conservation Rating NOOSAVILLE
Bn Basin u.n.d Unless noted otherwise L | System as defined by AS/NZS6400.
WS Water supply
Bth Both xX Shr Shower “Efe 7 Max 500kPa pressure| Provide flow restrictor valves where necessary DRAWING TITLE:
limiting valve within to taps and shower roses. The flow shall not
path box
FHR Fire Hose Reet O HWS Hot water system exceed ag maximum of 9L/min GENERAL NOTES &
cs Cleaners Sk LEGEND
stormwater Capilary bleed tubing
system discharge point from
first flush device, or
in gorden 1m away
Design| RK Checked Date | 11-5-07 Dwg. No.
RPB Towns SCALE : 1:100 ON Al UNO, 1 of 3 1740
main
RPD:— Lot 1 on RP73068
—+ oeSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
0015A77E.001.pdfRelated documentPublic source context ↗
07/0836 - Op Works - Landscaping, Carparking & Access [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file