2020-10-21 Final Order - Approval Conditions and Approved Plans - P&E Appeal No 61 of 2018 - RAL17-0504
Plans and drawings: the text below has words only, no drawings.
LEGEND 4.000 6.000 4.000
PROPOSED RETAINING WALL PROPOSED FILL AREA EXISTING MELALEUCA TREE
3.500
5.500
3.500
EXISTING CONTOUR EXISTING GUM TREE
600 x 600 FIELD INLET (TYP)
PROPOSED DRIVEWAY
* EXISTING CASUARINA TREE
EXISTING NON-NATIVE TREE
EXISTING NATIVE TREE
PASSING BAY DETAIL
SCALE 1:200 AT A1
SAIL STREET
WM
TPIT
TPIT
NBN EX RL 1.530
CONNECT Ø150 PVC PIPE TO EXISTING Ø450 BATTER DOWN TO
28 10 RCP PIPE CROSSING LAKE WEYBA DRIVE NBN
EXISTING GROUND LEVEL
EX RL 1.500
(RP72504) PP
TCOM
(1 IN 2.5 BATTER NOMINAL)
(RP72504) WM
WM
TPIT Ø150 UNDERGROUND 5.500m PASSING BAY
WM
STORMWATER PIPE
FH
9 (RP72504) 8 (RP72504)
A C B
29
RAISE ROAD LEVEL TO RL1.50 MIN
*
- - - *
(RP72504)
WM
* FH
PP
WM
23.2m NOM
DRIVEWAY (RL 1.500 MIN) REFER EXTERNAL
28.160 30.000 ROADWORKS DETAIL
3.500
DRIVEWAY CROSSOVER IN
ACCORDANCE WITH EX RL 1.456
22.000
8.000
LOT 2
6.000
IPWEAQ STD DRG RS-056
(1317m2)
TCOM
5.500m PASSING BAY
19.000
EX RL 1.375
BUILDING PAD (RL 2.600)
BUILDING PAD LB
LB
PP
30.000 0.80
LOT 1 (RL 2.600) CONNECT Ø150 PVC PIPE TO
0.61
EXISTING Ø350 PIPE AT IL 0.165
(1.492Ha)
GRADE NEATLY TO EXISTING
LOT 3 POSITION DRIVEWAY TO
(1574m2) IL 0.165
350dia RCP
LOT 3 TO AVOID TREES
11.3m NOM
28.300
34.300
SIGN
* 0.46
POSITION DRAINAGE
PIPE TO AVOID TREES
6.000
LAKE
EX RL 1.235
FIRE TRAIL EASEMENT
EX RL 1.200
22.267
BUILDING PAD (RL 2.600)
0.44
WEYB
LOT 4
(1731m2) 30.000
TCOM
WM 0.73
A
0.70
4.000
EX RL 0.989
DRIVE
PLAN OF DEVELOPMENT EXTERNAL ROADWORKS DETAIL
SCALE 1:500 AT A1 SCALE 1:200 AT A1
RP BOUNDARY
RP BOUNDARY
RP BOUNDARY
RP BOUNDARY
RP BOUNDARY
RP BOUNDARY
RETAINING WALL BUILDING PAD (RL 2.600)
3.500 1.250 3.500 E R 5.500
TT
BA
RL1.500 RL1.500 RETAINING WALL RL1.500
0.5 1:2.5 0.5
AY
DRIVEW
NOM RL1.0 EXISTING GROUND LEVEL NOM RL1.0 NOM RL1.0
J:\2017\17623SD2_4_Lot_Subdivision_at_135_Lake_Weyba_Drive\4.CADD\#ACAD\17623_CIVIL.dwg
Ø150 STORMWATER
PIPE
Ø150 STORMWATER Ø150 STORMWATER
SECTION A PIPE
SECTION B
PIPE
SCALE 1:50 AT A1 SCALE 1:50 AT A1 -
SECTION C
- SCALE 1:50 AT A1 -
0 0.5 1 1.5 2 2.5m 0 2 4 6 8 10m 0 5 10 15 20 25 m
1:50 (A1) 1:100 (A3) 1:200 (A1) 1:400 (A3) 1:500 (A1) 1:1000 (A3)
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
JC DR
This drawing is subject to
copyright in accordance with F 06.08.20 DESIGN AMENDED DM
WA Gabarrin & TO 135 LAKE WEYBA DRIVE PRELIMINARY PLAN OF DEVELOPMENT AS SHOWN A1
the agreement between TOD Designed Verified
Consulting Pty Ltd (tc) and tc's E 22.06.20 FIRE TRAIL EASEMENT AMENDED DM Gabarrin DR DR 4 LOT SUBDIVISION Drawing Number
client. This drawing shall only D 13.02.20 DESIGN AMENDED JC
be used for this specific project.
C 17.01.20 DESIGN AMENDED JC
Approved RPEQ No RP DESCRIPTION 17623-SK100
This drawing shall not be used Noosa: 07 5449 9600 Sunshine Coast: 07 5329 3190 D. REYNOLDS 9072 LOCAL AUTHORITY NOOSA COUNCIL
B 09.01.20 RE-ISSUED FOR APPROVAL JC MCU APPROVAL HORIZ DATUM 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566 Signed
A 06.01.20 ISSUED FOR APPROVAL JC [email protected] www.todconsulting.com ROL APPROVAL VERT DATUM
'Issued For Construction' in the
1 of 2 F
revision description. Rev Date Revision Description Drawn ABN 39 128 805 336 06.08.20 OPW APPROVAL RL DATUM MEASUREMENT BAR - INCREMENTS IN mm