Council archive · source document
Building Approval · MCU22/0116.01
Original PDF page 64, section 1. The text section number identifies this passage in the reader.
Z:\Public\client jobs\2000 - 2099 jobs\id 2014 22 Delorme St Noosa Heads PLAT RES\id 2014 22 Delorme St Noosa Heads PLAT RES issue F wdwgs.pln NOTE: SUBSTITUTION OF ANY STRUCTURAL MEMBERS, SIZES, GRADES OR ANY VARIATION TO ANY PART OF THE DESIGN WILL RENDER NULL AND VOID ANY RESPONSIBILITY OF IMAGE + DESIGN PTY LTD FOR THE STRUCTURAL INTEGRITY AND PERFORMANCE OF THE BUILDING CONSTRUCTION PLANS ELECTRICAL LEGEND SINGLE FLUORESCENT BATTEN WITH DIFFUSER CIRCULAR FLUORESCENT FITTING N DOWN LIGHT P PENCIL SPOT LIGHT H LOW VOLTAGE HALOGEN DOWNLIGHT LED LIGHT EMITTING DIODE (LED) BALL LIGHT FITTING WALL SCONCE METER pool WALL LIGHT WITH BRACKET hws D.P BOX D.P D.P ac unit equip SPECIAL LIGHT 2 2 D.P FLOOD LIGHT LED SINGLE g.p.o. (300 ABOVE FLOOR) LED LED SINGLE g.p.o. (1050 ABOVE FLOOR) 2 LED LED LED DOUBLE g.p.o. (300 ABOVE FLOOR) spp for remote 2 DOUBLE g.p.o. (1050 ABOVE FLOOR) controlled panelift spp for spp for DW LED LED door two handsets MW 2 DOUBLE g.p.o. FITTED WITH AN ISOLATION LED LED LED SWITCH FOR HOTPLATES supplied spp for HP spp for REF wp WATERPROOF g.p.o. spp for R'HOOD LED 2 2 LED LED CEILING FANS TO COMPLY WITH 2 B.E.R.S. ENERGY RATING clothesline S 2 TV D.P wp D.PD.P 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 TELEPHONE OUTLET (300 ABOVE FLOOR) D.P 2 TELEPHONE OUTLET (CONFIRM HEIGHT ON 2 LED wp SITE) hws S TV clothesline 2 TELEVISION OUTLET 13 12 11 10 9 8 7 6 5 4 3 2 1 ELECTRICIAL METER BOARD 2 spp for HP 2 LED spp for R'HOOD LED PHOTOELECTRIC SMOKE DETECTOR, sppLEDfor REF S HARDWIRED & INTERCONNECTED LED LED CEILING EXHAUST FAN TO EXTERNAL AIR spp for g GAS CONNECTION POINT MW spp for DW SWITCH POINTS @ 1350 OFF LED LED LED FLOOR LED LED 'COMBO' GLOBE HEAT LIGHT WITH FAN METER spp for remote BOX (AS SELECTED) LED controlled panelift door two handsets supplied LED LED LED LED 2 TV D.P D.P ac unit D.P pool equip FINAL LAYOUT TO BE CONFIRMED ON SITE BY Firewall must extend to end of Unit 2 Alfresco for fire separation CLIENT WITH ELECTRICIAN GROUND FLOOR ELECTRICAL PLAN 1:100 image+design id + QBSA Lic. No. 1123972 www.image-design.com.au [email protected] qbcc lic.no. 113908 SHEET PROJECT DRAWN CHECKED JOB NO. Proposed Residence TAKE DESIGN UNTIL ALL OUTSTANDING © COPYRIGHT RESERVED IN PART OR WHOLE, THESE DRAWINGS ARE THE PROPERTY OF IMAGE + DESIGN. PREFERENCE CONTRACTOR / BUILDER TO VERIFY DIMENSIONS FAILURE TO NOTIFY DESIGNERS OF DISCREPANCIES DESIGNERS REMAIN THE PROPERTY OF IMAGE & PLANS PUBLISHED 0421 662 426 Ph 07 4128 1333 Fax 07 4128 1133 21/06/2024 id 2014 14 THESE TH TH DIMENSIONS INVOICES ARE PAID IN FULL 22 Delorme St www.platinumproperties.com.au THE © COPYRIGHT RESERVED IN PART OR TITLE SCALE ISSUE OF RESPONSIBILITIES VOID WHOLE, THESE DRAWINGS ARE THE PROPERTY OF PLATINUM PROPERTY Noosa Heads GROUND FLOOR F 27 WRITTEN award winning building designs 1:100 @A3 u.n.o. SHALL GROUP ELECTRICAL PLAN
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Building Approval.pdfRelated documentApplication case desk ↗
About this file
- File size
- 7.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.