4
1 3
2
A5
A4
A3
A2
A1
3,078
9
8
10 SPA ABOVE POOL ABOVE
7
11
6
12
5
13
B4 4 B4
14
3
15
2
16
1
UP
DN 17
ACRYLIC WINDOW ACRYLIC WINDOW
190
190
4,178
871
B3 B3
7,418 14,799 2,101 14,939
BASEMENT
B2 B2
B5 UP B5
10,500
11,100
BASEMENT
190
BASEMENT
FL: 32.75
2400x4
B1 PDR B1
1,500
2750 CH
DRIVEWAY
800 TI
NON PERMEABLE
LT DO
190
FUTURE
OR
LIFT
1,610
B
14,195
190
190
190
8,242
DN
2,600
2,000
1. BASEMENT: 235.8
2. GROUND LIVING: 283.3
3. FIRST FLOOR LIVING: 256.9
4. GROUND FLOOR ALFRESCO: 71.3
A5
A4
A3
A2
A1
A
5. GROUND FLOOR PORCH: 4.7
6. FIRST FLOOR FRONT BALCONY: 24.5
7. FIRST FLOOR REAR BALCONY: 17.0
8. ROOF TOP TERRACE: 39.2
932.7 m²
0 1m 5m
Suite 7 / 10 Grebe St, Peregian Beach [email protected] www.suncoastbuildingdesign.com.au mob: 0401565629 mob: 0491289102 Revision Proposed Residence Address Client Avalon Homes Scale 1:150, 1:1
QBCC No: 1257143 (low rise)
Rev A - Amend Front roof pitch to 5 degrees Rev F - DA Plans - 20.08.25
Rev B - DA Issue Rev G - DA Plans - 09.10.25
#Project Description
This plan shall remain the sole property of Suncoast Building Design and must not be given, lent, hired out or otherwise disposed of or copied without the
Drawn MM/SB Page No. 6
Rev C - Major revisions per client meeting Rev H - RFI - 29.10.25
written permission of Suncoast Building Design.
Rev D - Garage reduced Rev I - RFI - 13.02.26
Note: all dimensions/engineer details and relevant information to be checked and confirmed by builder /client. Suncoast Building Design does not take
any responsibility after drawings have been checked and confirmed by builder/client or construction has commenced. Rev E - Updates as requested by client - 14.08.25 Job No. 20.148 Date 13.02.26 Stage DA Plans Drawing BASEMENT FLOOR PLAN
[OCR of page images]
SPAABOVE:
POOL ABOVE
2.101
14.939
Lo Lr
1,500 199,
1.610 199,
199,
U>
a<
o>
or
mo
OZ
4
un
property of ast Building Design and must not be given, lent, hired out or otherwise is ‘or copied without th
‘QBOON
writen permission of Suncoast Building Design,
Note: all dimensions/engineer details and relevant information tobe checked and confirmed by builder /olient ast Building Design does not take
Revision
Rev A- Amend Front roof pitch to 5 degrees
Rev B-DA|ssue
Rev O- Major revisions per olient meeting
Rev D - Garage reduced
Rev E - Updates as requested by client - 14.08.25
Rev F - DA Plans - 20.08.25
Rev G - DA Plans - 0910.25
RevH - RFI - 2910.25
Rev|-RFI -1302.26
Proposed Residence Address
#Project Description
Job No.
20148
Client — Avalon Homes
Drawn MM/SB
Date 13.02.26 Stage DAPlans
1. BASEMENT: 235.8
2. GROUND LIVING: 283.3
3. FIRST FLOOR LIVING: 256.9
4. GROUND FLOOR ALFRESCO: 71.3
5. GROUND FLOOR PORCH: 47
6. FIRST FLOOR FRONT BALCONY: 24.5
7. FIRST FLOOR REAR BALCONY: 17.0
8. ROOF TOP TERRACE: 39.2
932.7 m*
9 tm 5m
dF
Scale 1150, 1:1
PageNo. 6
Drawing BASEMENT FLOOR PLAN
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Proposal Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.