Council archive · source document
Planning Report · OPW22/0140
4.4 Sustainable Building Design Code
An assessment against the Performance Outcomes (PO8) of the Sustainable Building Design Code
is provided below.
Performance Outcome Comment
orientates buildings and The design includes large balconies extending from the open
windows to make the most of kitchen/living areas. All bedrooms include natural light and
prevailing winds, natural access to the balconies, while the orientation lets winter light
ventilation, and cross breezes;
in the living spaces and bedrooms. Importantly allows for
cross breezes and natural ventilation.
maximises shade to east and Eaves and wide balcony overhangs are included to shade
west walls; walls and windows.
contains an open and All dwellings have direct access to outdoor areas and large
permeable built form that balconies. The balconies connect to the living spaces to
connects indoor and outdoor provide BBQ and outdoor living opportunities.
spaces in an integrated design;
retains existing vegetation and Although not proposing to retain trees on the sloping sites,
natural shading where possible; the design proposes large plantings along both frontages to
allow for shading and a vegetated presentation to the street
and the internal driveways.
incorporates The design provides windows and large open areas to
passive building design to provide for passive cooling and natural breeze flow through
reduce the need for auxiliary the open plan design. Two out of the three bedrooms have 2
heating and cooling;
opening each, while the 1 bedroom has a large window over
with a window garden to help cool the air and providing clean
ventilation.
uses low toxic internal and A mix of low toxic internal and external materials are
external building materials; incorporated for the construction which will ensure long
lasting design that does not require regular maintenance.
uses natural light rather than Natural light is provided through byway of window and doors
artificial light, and may include to all levels.
skylights, atriums and light
wells;
provides a minimum floor to 2.7m floor to ceiling heights are provided to all dwellings.
ceiling height of 2.7 metres; and
enables efficient operation and The design allows for high density living and privacy to each
use of the building. of the units, while also allowing for users to easily flow
between the main living and bedrooms.
Page 13 of 16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.