5m 4 3 2 1
REV DESCRIPTION DATE
A Concept Issue 21/01/2013
B Design Development Issue 06/03/2013
C Body Corp Approval 18/03/2013
D Body Corp Approval 09/10/2013
E Revised Body Corp Approval 27/10/2013
CONSULTANTS
Surveyor
A B C D Max Watterson & Associates
P : 5442 6121 F : 5442 5125
Geotechnical
SCG Consulting Engineers
P : 5455 5604 F : 5455 5696
A A D Structural Engineer
3.1 3.1 3.2 C SCG Consulting Engineers
4.2 P : 5455 5604 F : 5455 5696
Hydraulic Engineer
SCG Consulting Engineers
P : 5455 5604 F : 5455 5696
6,230
6 6
B
3.1
Lysaght flat back 150mm 316 marine grade
stainless steel gutter with s/s fixings to treated
timber facia to be in accordance with
manufacturers specifications. Gutter to have
Balcony Below 1:200 fall to dp
Vergola Below
Flat roof over bathroom to be hand pitched in
timber with stainless steel cladding in
accordance with architects and engineer's
Lysaght flat back 150mm 316 marine grade stainless steel design and detail. Roof insulation to have foil
gutter with s/s fixings to treated timber facia to be in backed roofing felt and R3.5 ceiling batts.
accordance with manufacturers specifications. Gutter to Overall roof structure to achieve min. R4.6 in
have 1:200 fall to dp accordance with NCC 3.12.1.2.
1,500
5 1,500 B
5
2050
3.1
dp
4 4
1,500
150
Lysaght flat back 150mm 316 marine grade
150 stainless steel gutter with s/s fixings to treated
timber facia to be in accordance with
manufacturers specifications. Gutter to have
Flat 1:200 fall to dp
Roof
3 3
mrs1
B B
3° Pitch
3.1 3.1
Concrete block wall to be in accordance with structural
engineers design and detail. Provide Rockcote acrylic Selected metal roof sheeting to be fixed in
render system with sponge finish and painted with selected accordance with manufacturers specifications.
colour in accordance with final colour selections. Refer to Roof framing to be in accordance with
Rockcote for full coating system details. structural engineers design and detail. Roof
insulation to have foil backed roofing felt and
2,050 R3.5 ceiling batts. Overall roof structure to
achieve min. R4.6 in accordance with NCC
3.12.1.2.
2 2
2,164
Concrete block wall to be in accordance with
structural engineers design and detail. Provide
300mm Hebel awning to be fixed to concrete block walls in
Rockcote acrylic render system with sponge
accordance with manufacturers specifrications. Provide
finish and painted with selected colour in
Rockcote acrylic render system with sponge finish and
accordance with final colour selections. Refer
painted with selected colour in accordance with final colour
to Rockcote for full coating system details. Top
selections. Refer to Rockcote for full coating system details.
edge of parapet wall to have nominal fall
towards gutter behind.
B B
3.1 3.1
1 1
300mm Hebel awning to be fixed to concrete
block walls in accordance with manufacturers
specifrications. Provide Rockcote acrylic
render system with sponge finish and painted
with selected colour in accordance with final
colour selections. Refer to Rockcote for full
coating system details.
5,550
phil quayle architects
Ph: 5473 0188 Fax: 5473 0199
PO Box 1235, Noosa Heads Q 4567
[email protected]
C
4.2 project:
RESIDENCE
A A D for
3.1 3.1 3.2
Ingrid & Rob Aitken
A B C D Lot 23 Marcus Dunes Court
Castaways Beach
Floor Plan - Roof
1:100
LOT NO. 23
PLAN NO. SP111721
DRAWN MD
SUNSHINE COAST REGIONAL COUNCIL
SCALE (A2)
APPROVED PROJECT NO.
1512-03
MCU 13/0224 3 DEC 13 DRAWING NO.
1.4
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
APPROVED PLANS - MCU13/0224Related documentApplication case desk ↗
About this file
- File size
- 1.7 MB (small file)
- File type
No other editions are linked here.