Approved Plans - MCU13/0224
Plans and drawings: the text below has words only, no drawings.
5m 4 3 2 1
REV DESCRIPTION DATE
A Concept Issue 21/01/2013
B Design Development Issue 06/03/2013
C Body Corp Approval 18/03/2013
D Body Corp Approval 09/10/2013
E Revised Body Corp Approval 27/10/2013
t
x. heigh
8.0m ma ary
Selected metal roof sheeting to be fixed in accordance with m bound
manufacturers specifications. Roof framing to be in accordance x. heig ht 4m fro
with structural engineers design and detail. Roof insulation to 8.0m ma
have foil backed roofing felt and R3.5 ceiling batts. Overall roof
structure to achieve min. R4.6 in accordance with NCC
3.12.1.2. CONSULTANTS
Surveyor
Lysaght flat back 150mm 316 marine grade stainless steel 300mm Hebel awning to be fixed to concrete block Max Watterson & Associates
gutter with s/s fixings to treated timber facia to be in accordance walls in accordance with manufacturers specifrications. P : 5442 6121 F : 5442 5125
with manufacturers specifications. Gutter to have 1:200 fall to Provide Rockcote acrylic render system with sponge
dp finish and painted with selected colour in accordance
with final colour selections. Refer to Rockcote for full
Geotechnical
coating system details. SCG Consulting Engineers
P : 5455 5604 F : 5455 5696
Poweder coated aluminium vergola structure to be in Concrete block wall to be in accordance with structural
accordance with structural engineers design and detail. Painted Structural Engineer
engineers design and detail. Provide Rockcote acrylic
with selected colour in accordance with final colour selections. render system with sponge finish and painted with SCG Consulting Engineers
P : 5455 5604 F : 5455 5696
selected colour in accordance with final colour
RL 30.700 selections. Refer to Rockcote for full coating system
Cantilevered frameless glass balustrade with 100 x 50mm Pitching Point details. Hydraulic Engineer
recessed channel, neoprene setting block 25mm wide x 10mm SCG Consulting Engineers
thick, 1000mm long strips @ 750mm cts, non-shrink grout and P : 5455 5604 F : 5455 5696
one topping to be in accordance with manufacturers
specification, the NCC 3.9.2 and AS 1926. Balustrade to be min.
1000mm high above finished floor level. Provide 60mm dia.
stainless steel structural handrail to inside of glass balustrade.
Glass to be heat soaked treated. MATERIALS
RL 28.000 Concrete block retaining wall in accordance with ROOF - COLORBOND
First Floor structural engineers design and detail. To have stone WALLS - RENDERED MASONARY
cladding to pool side in accordance with manufacturers WINDOWS - ALUMINIUM
specifications. Refer to schedule of finishes for
cladding selection. Apply Rockcote acrylic render
system with sponge finish & painted with selected
colour in accordance with final colour selections to
garden side. Refer to Rockcote for full coating system
details.
Concrete block wall to be in accordance with structural
RL 25.000 engineers design and detail. Provide Rockcote acrylic
Ground Floor render system with sponge finish and painted with
selected colour in accordance with final colour
selections. Refer to Rockcote for full coating system
details.
Northern Elevation
03 1:100
Selected metal roof sheeting to be fixed in accordance with
manufacturers specifications. Roof framing to be in
accordance with structural engineers design and detail. Roof
insulation to have foil backed roofing felt and R3.5 ceiling
batts. Overall roof structure to achieve min. R4.6 in
accordance with NCC 3.12.1.2.
Lysaght flat back 150mm 316 marine grade stainless steel
Flat roof over bathroom to be hand pitched in timber with stainless gutter with s/s fixings to treated timber facia to be in
steel cladding in accordance with architects and engineer's design accordance with manufacturers specifications. Gutter to have
and detail. Roof insulation to have foil backed roofing felt and R3.5 1:200 fall to dp
ceiling batts. Overall roof structure to achieve min. R4.6 in
accordance with NCC 3.12.1.2.
RL 30.700
Suspended concrete balcony to be in accordance with engineers Pitching Point
design and detail. Provide tile bedding with fall away from building
in accordance with NCC 3.1.2.3. Provide Emer-Proof 750 water Concrete block wall to be in accordance with structural
proofing barrier installed in accordance with manufacturers engineers design and detail. Provide Rockcote acrylic render
system with sponge finish and painted with selected colour in
specifications overlaid with cement based screed and selected
accordance with final colour selections. Refer to Rockcote for phil quayle architects
external non-slip tiles in accordance with manufacturers
specifications. Tiles to be cut to suit terrace falls. Provide recessed full coating system details.
drip groove to underside of terrace.
Ph: 5473 0188 Fax: 5473 0199
RL 28.000 PO Box 1235, Noosa Heads Q 4567
First Floor [email protected]
Cantilevered frameless glass balustrade with 100 x 50mm recessed
channel, neoprene setting block 25mm wide x 10mm thick, 1000mm project:
long strips @ 750mm cts, non-shrink grout and one topping to be in Frameless glass panels with 100 x 50mm recessed channel,
accordance with manufacturers specification, the NCC 3.9.2 and AS neoprene setting block 25mm wide x 10mm thick, 1000mm
long strips @ 750mm cts, non-shrink grout and one topping to
1926. Balustrade to be min. 1000mm high above finished floor level.
Provide 60mm dia. stainless steel structural handrail to inside of be in accordance with manufacturers specifications to form
pool fence in accordance with the Building Act 1975, Building
RESIDENCE
glass balustrade. Glass to be heat soaked treated.
Regulation 2006, AS 1926 and Queensland Development
RL 25.000 Code MP 3.4-Swimming pool barriers. Pool fence to be min. for
Ground Floor 1200mm high above adjoining finished surface level and have
250mm concrete slab edge detail in accordance with architect's
detail. Provide Granotex waterproof style render system and 900mm non climbing zone as specified in pool legislation.
painted with selected colour in accordance with final colour
selections. Concrete steps to be in accordance with structural engineers Ingrid & Rob Aitken
design and detail. Steps to have selected slip resistant
external tiles laid in accordance with manufacturers
specifications. Tiles shall comply with NCC 3.9.1.
Lot 23 Marcus Dunes Court
Concrete block retaining wall in accordance with structural
engineers design and detail. To have stone cladding to pool side in Castaways Beach
accordance with manufacturers specifications. Refer to schedule of
finishes for cladding selection. Apply Rockcote acrylic render
system with sponge finish & painted with selected colour in
accordance with final colour selections to garden side. Refer to
LOT NO. 23
Rockcote for full coating system details.
Eastern Elevation
04 1:100 PLAN NO. SP111721
DRAWN MD
SUNSHINE COAST REGIONAL COUNCIL SCALE (A2)
PROJECT NO.
APPROVED 1512-03
DRAWING NO.
MCU 13/0224 3 DEC 13
2.2