APPENDIX 3 – PROPOSAL PLANS P a g e | 43 TOWN PLANNING REPORT [OCR of page images] APPENDIX 3 —- PROPOSAL PLANS Page |43 TOWN PLANNING REPORT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 11 pages
Page 2
APPROVAL ISSUE C - Bennett Residence - 19 Attunga Heights, Noosa Heads
dennishillarchitect
[OCR of page images]
APPROVAL ISSUE C - Bennett Residence - 19 Attunga Heights, Noosa Heads
Page 3
COPYRIGHT: Drawings remain the Copyright of the Architect: Dennis Hill Architect LICENSED TRADESPERSONS: All services to be installed by licensed tradespersons • no exposed gables to joinery unless noted otherwise
ALL WORKS shall be carried out in accordance with the Building Code of Australia, in accordance with local authority and with current manufacturers specifications.
Australian Standards, Local Council requirements, QDC guidelines and all other ROOF DRAINAGE: All downpipes to be located as noted on the drawings and sizes as • all tops and carcasses to be flush unless noted otherwise
relevant by laws and authorities. In particular refer Australian standards: scheduled. Allow to connect to in-ground storm water drains with 90mmDIA UPVC at
general construction notes
. site preparation A.S. 3798 1:100 minimum grade. Allow for I.O.'s at each change fo direction and at 6000mm • all edges to be square unless noted otherwise
. termite protection BCA and A.S. 3660.1 centres
general joinery notes
. artificial lighting & ventilation BCA parts 3.8.4/3.8.5 and A.S. 1680 SITE DISCHARGE: All stormwater and sanitary plumbing to be connected to existing • all joinery units to have carcass constructed of 16mm or 25mm thick
. fire safety BCA part 3.7 council system in accordance with the requirements of the relevant local authority. pre-finished board unless noted otherwise
. smoke alarms BCA part 3.7.2 and A.S. 3786 WATER LINES: All hot water lines shall be fully insulated. All domestic hot water to
. glazing BCA part 3.6 and A.S. 1288 and A.S. 2047 basins, showers and baths to have maximum temperature of 50°C. Allow to supply • all laminated joinery to have matching abs edging unless noted otherwise
APPROVAL: No building work shall be undertaken prior to Building Approval by a and install tempering valves where required, as nominated in the BCA and
registered Certifier. relevant standards. • all joinery units to have 100mm high skirting unless noted otherwise
CONSULTANTS : Drawings shall be read in conjunction with engineers drawings and STAIR AND BALUSTRADES: All stair and balustrades shall comply with part 3.9 of
computations. All structure to Engineers design. All drawings to be co-ordinated with the BCA. Steps to be provided where fall from dwelling exceeds 190mm. • all timber veneer joinery to have matching solid timber edging
consultant documentation prior to construction. ALL PRODUCTS: To be installed to manufacturers requirements and to be in
DIMENSIONS: Do not scale off drawings - use figured dimensions only. Contractor accordance with manufacturers requirements for suitable exposure levels. • all drawers to have high sides
shall verify all dimensions on site prior to construction. Any discrepancies or errors PROPRIETARY ITEMS: Identification of a proprietary item does not necessarily imply
shall be referred to architect and client prior to installation / manufacture of any works. exclusive preference for the item so identified, but indicates the necessary properties • all adjustable shelves shall be supported on brass ferrules and bushes
Confirm levels & RL's on site prior to commencement of work. of the item. If alternatives are proposed, submit proposed alternatives and include - supports to be at 50mm centres
SETOUT: Contractor to confirm exact siting and orientation prior to construction samples, available technical information, reasons for proposed substitutions and cost.
setout. All building setout and confirmation of setbacks and height to be carried out by TILES: Expansion joints, walls: 5mm. Floors: 8mm. Fill both with silicone rubber. Grout • all hinged doors to be hung on fully concealed all metal type wide
a Licensed Surveyor. No footing, or wall to encroach the title boundary. for wall: Epoxy based mildew resistant. Grout for floors: prepared grout to be acid angle hinges
TERMITE PROTECTION: Termite protection by means of termimesh s.s. mesh resistant. all wall tiles to have fc substrate.
physical barrier in accordance with A.S. 3660.1/2000 and installed in strict accordance INTERNAL PAINTING: Unless noted otherwise paint system to be Dulux approved 3 • all cover plates, gpo's and data outlets etc to be white if located on
with current manufacturers specifications. coat system - low sheen finish. Colours to be supplied by Architect during contract and white wall or corian, otherwise to be stainless steel finish
STRUCTURAL STEEL: Unless noted otherwise all exposed structural steel, anchor applied as per Dulux's recommendations and guidelines.
bolts and other attachments shall be hot dip galvanised. A cold gal painted finish shall JOINERY ITEMS SHALL INCLUDE: Manufactured casework items, including: kitchen • builder to provide adequate noggings to support all bathroom
be applied to any field welding to existing or new steelwork. All steel work cast in cabinets and cupboards; bathroom cabinets; robes. accessories and suspended joinery
concrete footings or slab shall have a bitumen finish applied to full extent of cast in SANITARY COMPARTMENTS: Provide removable hinges to doors of sanitary
concrete steel. Check all dimensions on site prior to fabrication of steelwork. compartments to comply with BCA 3.8.3.3 and be readily removable from outside • all dimensions to be checked on site prior to manufacture of joinery
RETAINING WALLS: All retaining walls to structural engineers details. Provide rubble unless there is a clear space of at least 1200mm b/w closet pan within the sanitary
backfill and agg drainage to all retaining walls. Builder to provide tanking where compartment and the nearest part of the doorway. • finish to underside of overhead cupboards to match joinery fronts
required. APPLIANCES & EQUIPMENT: Builder to co-ordinate all appliance and equipment
SLAB & FOOTINGS: All slabs and footings to structural engineers details. A locations on site and with joiner. installation and final connection by the contractor. • all joinery drawings to be read in conjunction with architectural
polyethylene moisture barrier shall be lapped 200mm and fully taped under any WEATHERSTRIPS: All external doors to contain weather stripping (type to be drawings and finishes & fixtures schedule - all discrepancies to be
habitable concrete slab and shall extend 100mm onto the perimeter footing. confirmed by Architect prior to manufacture) referred to the builder and architect for resolution
ARTICULATION JOINTS: Provide articulation joints to comply with "Cement and DOCUMENTATION: The contractor shall carry out works in accordance with the
Concrete Association Construction Note TN9". signed drawings and schedules and anything reasonable inferred, and with the • builder to co-ordinate all appliance and equipment locations on site
EROSION CONTROLS: All building works to comply with local authorities Erosion and Conditions of Contract, and in accordance with the directions and to the satisfaction of and with joiner. Installation and final connection by the contractor.
sediment control standards. the Architect, whose interpretation of the contract documents shall be final. The Joiner to confirm all appliance and equipment tolerances and
WATERPROOFING: All wet areas and walls to be waterproofed in accordance with drawings and specifications/schedules shall be considered complementary, and any requirements in joinery prior to fabrication
the BCA 3.8 & AS 3740. Builder to provide certificate of installation and compliance. work and/or materials absent from one but present or implied in the other shall be
CONCEALMENT OF SERVICES: All services shall be concealed in walls or ducts. furnished as if they were present in both.
Where services are exposed they must be confirmed by the Designer on site prior to FINAL CERTIFICATE: At completion of work - Builder to obtain.
installation unless noted otherwise.
19 Attunga Heights TOTAL SITE 505.560 m² bal01 timber framed glass balustrade con01 large format concrete paver FSL X.XXX spot level
Noosa Heads Qld 4555
Council - Noosa Council SITE COVER 216.165 m² = 42.7% bal02 timber balustrade pol01 polished concrete TOW X.XXX top of wall / fence level
Site Area: 505.560 m² GFA - Undercroft N/A fc01 scyon axon fibre cement cladding tim01 hardwood timber floor SSL X.XXX structural slab level
Lot: 10 on RP 89506 GFA - Ground Level 174.715 m²
Building Classification: 1a GFA - Upper Level 96.950 m² pb01 plasterboard lining tim02 hardwood timber decking FFL X.XXX finished floor level
Storeys: 2 TOTAL GFA 271.665 m²
Climate Zone: 2 PLOT RATIO 0.537:1 (53.7%) vj01 vj sheet lining L1 indicates building level
project details
w01 indicates window number
floor areas
Wind Category N3
mrf01 metal flashing - colorbond finish
finishes
finishes
legend
L1 indicates building level
d01 indicates door number
mrs01 metal roof sheeting - colorbond finish
pnt01 epoxy paint finish pnt01 finish/material type as scheduled
20
ren01 rough sand and cement render slab setdown
hc
tbs01 timber batten screen hose cock
dp
ms01 metal screen down pipe
dr01
til01 crazy paving drainage pit
til02 ceramic tile
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence COVER NOTES DRH B Concept Issue B 20/03/2025
dennishillarchitect C Building Approval A 26/03/2025
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.001
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:19 PM
Page 4
neighbouring upper level
Drawing Schedule
Current
neighbouring garage neighbouring driveway Revision
Sheet No. Sheet Name Revision Date
BOUNDARY 25.146 m 90° 03' 00"
APRVL.00 COVER SHEET E 14/04/2025
sewer manhole s APRVL.01 SITE PLAN E 14/04/2025
invert = -1600mm from lid APRVL.001 COVER NOTES E 14/04/2025
APRVL.02 UNDERCROFT E 14/04/2025
APRVL.06 GROUND LVL - FLOORPLAN E 14/04/2025
6000mm setback
4500mm setback
APRVL.07 UPPER LVL - FLOORPLAN E 14/04/2025
APRVL.09 ROOF DRAINAGE PLAN E 14/04/2025
APRVL.11 ELEVATIONS E 14/04/2025
APRVL.12 ELEVATIONS E 14/04/2025
APRVL.13 BOUNDARY WALLS D 14/04/2025
APRVL.Z.17 3D PERSPECTIVES E 14/04/2025
line of upper level walls under
19 Attunga Heights
BOUNDARY 20.105 m 180° 03' 00"
BOUNDARY 20.105 m 0° 03' 00"
Attunga Heights
1500mm setback
2000mm setback
2500mm setback
2500mm setback
2000mm setback
1500mm setback
BOUNDARY 25.146 m 270° 03' 00"
Plan neighbouring driveway
Site Plan 1 : 100
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence SITE PLAN DRH B Concept Issue B 20/03/2025
dennishillarchitect C Building Approval A 26/03/2025
065 As indicated
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.01
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:20 PM
Page 5
3000 190 5820 190 2300 190 7220 190 4046 2000
sewer manhole neighbouring garage neighbouring driveway
invert = -1600mm from lid
190
790
s
pool pump
190
2000
6000mm setback
4500mm setback
3415
190
pool
wall mounted
AC units
5210
190
undercroft
4330
RWT RWT
190
190 3620 90
11500
90
plant +
1800
equip
laundry
20105
95 1000 190 1200 190 1000 190
13220
lift
garage
hallway
190
drying plant +
court equip
bthrm
3135
1500mm setback
2000mm setback
2500mm setback
6225
190
vent screen vent screen vent screen
2500mm setback
2000mm setback line of ground floor over
driveway
2900
1500mm setback
total GFA = N/A
neighbouring driveway 1260 1560 190 1600 190 3110
3000 90 1730 90 3000
3000 190 7620 190 7910 190 6046
Plan
Undercroft 1 : 100
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence UNDERCROFT DRH B Concept Issue B 20/03/2025
dennishillarchitect C Building Approval A 26/03/2025
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.02
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:23 PM
Page 6
11500 11646 2000
2400 600 6200 2300 7600 6046 Plan
Ground Level 1 : 100
190 5820 190 2300 190 6020 90 1110 190 4046 2000
neighbouring garage neighbouring driveway
190
980
BALUSTRADE
2000
2600
3605
6000mm setback
4500mm setback
BALUSTRADE
190
2625
TV
line of eave over
pool
living
EXISTING TREE
line of eave over
alfresco
3900
6915
BALUSTRADE
4500
line of eave over
8415
190600
190 810 190
190
Attunga Heights
dining
190
entry
PLANTER
2910
20105
1910
1910
13600
190
190
190
1200
F
lift study
1800
2210
2330
pdr
1200
kitchen
90 190
line of eave over
510
90 90
ROBE
90
90600
510
ROBE
90
900
EXISTING TREES
butlers
90
3200
3030
bed 2
1500mm setback
2000mm setback
2500mm setback
2910
3220
bed 3 bed 1
ROBE
bthrm
ROBE
2320
190
190
400
400
90
2500mm setback line of eave over
2000mm setback
2710
driveway
2500
2500
2500
1500mm setback
190
190 900 4920 1500 3040 190 1600 410 2510 100
90 90 90 190 190 90 total GFA = 174.715m²
190 1920 3200 510 2440 510 3000 3600 100
90 90 90 90 90 90 90 neighbouring driveway site cover = 216.165m²
3000 2110 6510 7480 6046
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence GROUND LVL - DRH B Concept Issue B 20/03/2025
dennishillarchitect FLOORPLAN C Building Approval A 26/03/2025
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.06
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:25 PM
Page 7
2400 1000 5800 600 1700 600 7000 600 5446
140 860 190 5420 190460
140 800 190 1310 190 6620 190
1190 190 2620 190 1630 190 1470 4160 90 2400 190
3540 90 2990 190
neighbouring garage neighbouring driveway
2000
3605
6000mm setback
4500mm setback
190 140
460
190
190
2240
4830
4830
master bed
90
5310
balcony
ensuite
3000
190
190
plunge
190600
pool
220 1200 190 1000 90 820 190
90
4120
1580
skylight
2190
3.46m²
190 1060 190
lift
9005
6700
7520
retreat
WIR
pool pump
under
4000
3445
1500mm setback
2000mm setback
2500mm setback
190
FR BAR TV
1500
190
140 190
190
190
460
2500mm setback
2000mm setback
2500
2500
1500mm setback
total GFA = 96.950m²
Plan 190 3030 190 1600 95
95 3110 190
Upper Level 1 : 100 neighbouring driveway
190 5120 90 2910 190
2400 600 7600 5500 3000 600 5446
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence UPPER LVL - DRH B Concept Issue B 20/03/2025
dennishillarchitect FLOORPLAN C Building Approval A 26/03/2025
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.07
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:30 PM
Page 8
ROOF DRAINAGE 10000 600 900 600 7000 600 5446
NOTES:
All work to conform with Part MP 4.2 of the
Queensland Development Code (QDC)
3005
(Water Saving Targets).
6000mm setback
4500mm setback
Roof stormwater is to discharge to local
government requirements and approval.
Tank/s overflow and downpipes not
connected to rainwater tank/s to discharge
600
600
to interallotment drainage system/ to
nominated discharge points via bubbler
system/ to discharge to street channel system.
Based on assumed 5 minute rainfall intensity -
258mm/h 20 years recurrence interval.
line of upper level walls under
5500
Gutters & downpipes shall be in accordance
with AS/NZS3500.5 domestic & Part 3.5.2, Vol 2
of the NCC.
skylight
All downpipes to be 90mm/100mm U-PVC.
All gutters to be 150 Half Round Gutters
(7042mm² Cross section area).
Falls to be in accordance with clause 3.5.2.4,
Vol 2 of the NCC.
• Effective roof catchment area (dwelling
13400
only) 130 m²
• Roof catchment per downpipe 50m²
• Downpipes must not serve more than
12m of gutter length for each downpipe
skylights
• Total rainfall intensity 130m² X 258mm/50 =
670.8L/min
• Stormwater pipes - 100 dia. Laid at 1 in
100 minimum grade.
Roof Catchment Area
7900
Downpipes are to be located where they will
not create a hazard to building users nor 130m²
impede window & door openings and the
like. kliplok roofing
3.0°
They are to be installed as close as
practicable to the supporting structure while
maintaining termite inspection clearances of
1500mm setback
2000mm setback
2500mm setback
25mm. Downpipes are to be protected from
potential mechanical damage, be installed
no less than 100mm from electrical cables &
gas pipes & no less than 50mm from other line of upper level walls under
services (AS3500.3.2 S4.11)
600
600
Downpipes are to service 12m maximum 2500mm setback
gutter length & be within 1.2m from each 2000mm setback
valley unless overflow is provided for (NCC
2500
Vol2 7.4.5) 1500mm setback
site cover = 216.165m²
Plan 600 8500 600
Upper Level Pitching 1 : 100
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence ROOF DRAINAGE DRH B Concept Issue B 20/03/2025
dennishillarchitect PLAN C Building Approval A 26/03/2025
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.09
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:30 PM
Page 9
2500 3016
BOUNDARY
BOUNDARY
Upper Level Pitching
RL 70.250 m
Upper Level
RL 67.550 m
Ground Level
RL 64.550 m
17 Attunga Heights 19 Attunga Heights 21 Attunga Heights
1 Elevation
East Elevation 1 : 100
2978 2500
BOUNDARY
BOUNDARY
Upper Level Pitching
RL 70.250 m
2000 2500
Upper Level
RL 67.550 m
Ground Level
7300
7300
RL 64.550 m
Undercroft
RL 61.550 m
2 Elevation
West Elevation 1 : 100
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence ELEVATIONS DRH B Concept Issue B 20/03/2025
dennishillarchitect C Building Approval A 26/03/2025
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.11
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:34 PM
Page 10
8m max heigh
t
Upper Level Pitching
RL 70.250 m
Upper Level
RL 67.550 m
Ground Level
RL 64.550 m
NGL
1 Elevation
North Elevation 1 : 100
Undercroft
RL 61.550 m
5458
6058
BOUNDARY
3000
height
8m max
2400
Upper Level Pitching
RL 70.250 m
BOUNDARY
Upper Level
6788
RL 67.550 m
6915
Ground Level
RL 64.550 m
VENT VENT VENT
2598
14.0°
NG L
Undercroft
RL 61.550 m
2 Elevation
South Elevation 1 : 100
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence ELEVATIONS DRH B Concept Issue B 20/03/2025
dennishillarchitect C Building Approval A 26/03/2025
065 1 : 100
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.12
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:38 PM
Page 11
Upper Level Pitching
RL 70.250 m
Upper Level
RL 67.550 m
1000m(h) from pool side to provide fall-prevention
2470
2000
1000
2000
Ground Level
1800
RL 64.550 m
2997
NGL
190 2740 4280 100 4400 100 8295
NGL at neigh
1800
2190 bou ring lot
13646
1 Elevation 2 Elevation 11500
East Elevation - Boundary Wall 1 : 150 North Elevation - Boundary Wall 1 : 150
Upper Level Pitching
RL 70.250 m
Upper Level
RL 67.550 m
Ground Level
RL 64.550 m
1800
1800
g lot
ighbourin
NGL at ne
1800
1800
Undercroft
RL 61.550 m
NGL
20105
4 Elevation 3 Elevation
West Elevation - Boundary Wall 1 : 150 South Elevation - Boundary 1 : 150
Wall
No. Description Date
Project Client Drawing Drawn by A Concept Issue B 20/03/2025 Project number Scale at A3
19 Attunga Heights Bennett Residence BOUNDARY DRH B Building Approval A 26/03/2025
dennishillarchitect WALLS C Building Approval B 27/03/2025
065 1 : 150
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D Building Approval C 14/04/2025
APRVL.13
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:42 PM
Page 12
No. Description Date
Project Client Drawing Drawn by A Draft Issue A 17/03/2025 Project number Scale at A3
dennishillarchitect 19 Attunga Heights Bennett Residence 3D PERSPECTIVES DRH B
C
Concept Issue B
Building Approval A
20/03/2025
26/03/2025
065
mobile: 0438 20 55 66 | [email protected]
www.dennishillarchitect.com
D
E
Building Approval B
Building Approval C
27/03/2025
14/04/2025 APRVL.Z.17
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright. 14/04/2025 3:52:42 PM
Used in these records
Proposal Plans (rec. 16.04.25).pdfRelated documentApplication case desk ↗
About this file
- File size
- 12.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.