Log in to see the plans as drawn1.48
66.7
0.104
0.140
0.105
1.50%
30.471
uPVC SN10
30.471 E 491325.098 124.730 123.651 1.079 124.730 STD FIELD INLET. TYPE 2 STD DRG DS-050 2-2
N 7076028.248 123.631 1.099 124.678 900x900
375
2.53
1.75
66.7
0.086
0.254
0.193
1.50%
30.583
uPVC SN10
124.596
61.054 E 491332.869 124.631 123.172 1.459 124.631 STD FIELD INLET. TYPE 2 STD DRG DS-050 3-2
STAGE 2
N 7076057.827 123.152 1.479 124.374 900x900
1% AEP HGL
2
PO Box 899
07 5443 8285
525
3.13
2.07
66.7
0.092
0.623
0.448
1.50%
15.013
uPVC SN10
ABN 29 679 702 599 76.067 E 491347.704 124.480 122.927 1.553 124.300 STD FIELD INLET. TYPE 2 STD DRG DS-050 4-2
Maroochydore 4558
N 7076055.522 122.907 1.573 124.133 900x900
barlowshelley.com.au
Barlow Shelley Pty Ltd
525
3.21
2.35
66.7
0.623
0.508
1.50%
25.200
[email protected]
uPVC SN10
101.267 E 491372.596 124.330 122.529 1.801 123.882 STD FIELD INLET. TYPE 2 STD DRG DS-050 5-2
N 7076051.594 122.509 1.821 123.681 900x900
525
3.22
2.42
66.7
0.623
0.523
1.50%
15.193
PROJECT:
uPVC SN10
116.460 E 491383.351 124.050 122.281 1.769 123.520 STD FIELD INLET. TYPE 2 STD DRG DS-050 9-1
N 7076040.862 121.881 2.169 123.425 900x900
DRAWING TITLE:
WITH 1200 MANHOLE BASE
10% AEP HGL
0.000 E 491339.312 124.730 STD FIELD INLET. TYPE 2 STD DRG DS-050 1-3
N 7076118.461 123.925 0.806 124.730 900x900
108.000
300
1.93
1.29
83.3
0.090
0.125
0.091
1.20%
30.427
uPVC SN10
30.427 E 491334.577 124.730 123.559 1.171 124.730 STD FIELD INLET. TYPE 2 STD DRG DS-050 2-3
3
FOR RMD CAPITAL PTY LTD
STAGE 3
N 7076088.405 123.539 1.191 124.677 900x900
1% AEP HGL
375
2.28
1.62
83.3
0.072
0.227
0.178
1.20%
30.626
AT 18 TAYLOR COURT, COOROY
uPVC SN10
124.596
61.053 E 491332.869 124.631 123.172 1.459 124.631 STD FIELD INLET. TYPE 2 STD DRG DS-050 3-2
STAGE 2
N 7076057.827 123.152 1.479 124.374 900x900
STORMWATER LONGITUDINAL SECTIONS
PROPOSED INDUSTRIAL DEVELOPMENT
-
1 OCTOBER 2026
NOOSA COUNCIL
APPROVED PLAN
C320
2576
JOB NUMBER
DRAWING NUMBER
MCU26/0040, OPW26/0066 & RAL26/0013
REV
B
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.