REV DESCRIPTION DRN DATE
A MCU DA Issue MS 25.02.20
Generally throughout: B MCU DA Issue MS 02.03.20
- New render and paint finish to all external walls C MCU DA Issue MS 06.03.20
- New anodised aluminium (25µm coating) D Client Revisions MS 14.04.20
sliding doors to terraces / balconies
- New anodised aluminium (25µm coating) windows
- New frameless glass balustrade with
anodised aluminium (25µm coating) uprights
- New tiles to walkways, terraces and balconies
200 x 50 powdercoated
Existing Fire Stair 03 core with New 200 x 50 powdercoated aluminium awning portal New 200 x 50 powdercoated aluminium awning
15 m height line - New powdercoated aluminium aluminium portal frame to shower
Property Boundary
Property Boundary
feature powdercoated New bar and shelving frame to future detail, supported by RHS columns with frame with powdercoated 'timber-look'
measured from NGL gate and side screen to area, supported by RHS columns
aluminium placards and resort joinery unit to future detail select powdercoated 'timber-look' aluminium battens aluminium battens under and select
at face of building recessed roof terrace entry with selected laser cut feature
signage fixed to blockwork wall over and 50 x 50 SHS capping to top of frame polycarbonate roof sheeting over to future detail
RL 18.464 screen to top and short sides
LIFT ROOF
2393
RL 16.071
LIFT PLANT
New 100 x 25 powdercoated
2290
aluminium screen fixed to
wall / slab edge
U409 Terrace
RL 13.781
ROOF TERRACE
2768
U409 New frameless glass balustrade with
No Internal Works anodised aluminium channels top
RL 11.013 and bottom, fixed to upstand wall
THIRD FLOOR
Screen Screen
2787
U309
No Internal Works
RL 8.226
SECOND FLOOR
2756
U209 Pool Terrace
No Internal Works
RL 5.470
FIRST FLOOR
3232
Courtyard Lobby Reception Carpark
RL 2.238
GROUND FLOOR
New 'floating' roof over 200 x 50 powdercoated aluminium awning frame New frameless glass
New raised terrace to New anodised aluminium-framed
raised timber deck. Select supported by reinforced concrete blade columns. balustrade and gate with
cafe with select timber shopfront glazing, glass swing door and
Colorbond / standing Provide 50 x 20 battens to underside of frame, anodised aluminium uprights,
decking to future detail bi-fold window to existing bar area.
seam roof sheeting over select polycarbonate roof sheeting over fixed to slab edge downturn
SECTION A
Scale 1:100
200 x 50 powdercoated
New roof structure over fire New 200 x 50 powdercoated aluminium awning portal New 200 x 50 powdercoated aluminium awning
15 m height line - aluminium portal frame to shower
Property Boundary
Property Boundary
stair extension. Provide roof Existing Lift frame to future detail, supported by RHS columns with frame with powdercoated 'timber-look'
measured from NGL area, supported by RHS columns
cover for full extent of stair Core 01 behind select powdercoated 'timber-look' aluminium battens aluminium battens under and select
at face of building with selected laser cut feature
and bridge link behind over and 50 x 50 SHS capping to top of frame polycarbonate roof sheeting over to future detail
RL 18.464 screen to top and short sides Suite 2,
LIFT ROOF
Cnr Gard
2393
Alexand
PO Box
RL 16.071
LIFT PLANT P 07 54
admin@
2290
U411 Terrace
RL 13.781
ROOF TERRACE SUNCOAST RESORT BUSINESS CENTRE
New frameless glass balustrade with SUITE 2 CNR GARDAK ST & SURF RD
anodised aluminium channels top ALEXANDRA HEADLAND Qld 4572
2768
U411 and bottom, fixed to balcony slab PO BOX 6232 MAROOCHYDORE BC Qld 4558
No Internal Works PH : 07 5443 5028 FAX:07 5479 2380
RL 11.013 ABN 23 123 917 724
THIRD FLOOR EMAIL: [email protected]
100 x 25 powdercoated aluminium
Building A behind. Refer to Screen pergola frame fixed to slab edge
project
2787
Section A for more details Fire Stair 01 U311 downturn. Horizontal member fixed
No Internal Works
to slab edge / upstand wall above PROPOSED ALTERATIONS &
RL 8.226 ADDITIONS TO EXISTING
SECOND FLOOR RESORT BUILDING
for
2756
U211 NETANYA RESORT
No Internal Works
RL 5.470 at
FIRST FLOOR 75 HASTINGS STREET
NOOSA HEADS
3232
drawing
Lobby Carpark
NEW WORKS - SECTIONS
RL 2.238
GROUND FLOOR
New frameless glass balustrade 200 x 50 powdercoated aluminium
New planter and feature New extension to New raised New frameless glass pool fence
Existing tenancies - with anodised aluminium awning frame with 1200 mm high
timber screen to entry existing Fire Stair 01 blockwork wall and gate on anodised aluminium AS SHOWN
no works uprights and handrail, fixed to blockwork wall under. 150 x 50 hardwood
courtyard shown behind to future detail
existing floor structure
planter to future detail spigot fixings to future detail
timber batten screen infill to future detail date 14/04/2020 drawn JP scale @A1
SECTION B drawing no. 19021 SD30.02 revision D
Scale 1:100
Copyright of this document remains the exclusive
property of SPROUT ARCHITECTS PTY LTD
ABN 23 123 917 724.
Contractors are to verify all dimensions and levels on
site prior to commencing. Report all discrepancies to
the Architect. Use figured dimensions in preference
0 5 10 20 to scaled.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 64.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.