Council archive · source document
Att 1_Architectural Plans · MCU13/0081.01
Plans and drawings: the text below has words only, no drawings.
Very large file (64.9 MB): may take a few minutes to open.
Original PDF page 25, section 1. The text section number identifies this passage in the reader.
REV DESCRIPTION DRN DATE
New fire exit from A MCU DA Issue MS 25.02.20
basement to ground level. B MCU DA Issue MS 02.03.20
Staircase to future detail C MCU DA Issue MS 06.03.20
D Client Revisions MS 14.04.20
Existing stair over to remain,
entering 'Sails' restaurant
Exit
Gate
up
ir
Sta
Hot Water
ir
Sta
Systems
dn
up
Screen
New, reconfigured entry /
Ste
exit fire escape stairs and px
Store 2
60
platforms to conform Gate
with current building COL
standards to future detail
90
16
DP
Gate
dn
Provide extension to
existing planter under
0
30
new feature stair
ir
Sta
100 x 25 powdercoated Feature 100 x 25
Existing 'Sails' restaurant
aluminium screen and gate (Plant powdercoated aluminium
up behind; no works
area behind) to future detail screen direct fixed to wall face
Existing walkway planters New feature entry / exit stair to
Existing water feature and planter
and footpath to be common landing. Provide frameless
section removed to provide new
reconfigured / added to suit glass balustrade to anodised batten Generally throughout:
70
Entry / Exit to existing Amenities
substation doors and gates screening to street front
56
- New render and paint finish to all external walls
- New anodised aluminium (25µm coating)
ir
Sta
sliding doors to terraces / balconies
Downpipe to be concealed
within structural column, to - New anodised aluminium (25µm coating) windows
up
future detail, T.B.C. - New frameless glass balustrade with
anodised aluminium (25µm coating) uprights
- New tiles to walkways, terraces and balconies
25 Provide tactile indicators
COL 6
Plant 89 0
0 Entry as per AS 1428.4.1 and
NCC requirements
80
88
5 14
DP
ct
Du
New storage and sanitary facilities Feature frameless glass
Feature 100 x 25 Feature batten wall 100 x 25 powdercoated
above existing substation on balustrade fixed to slab edge.
powdercoated aluminium cladding to new wall aluminium screen fixed
elevated floor. New roof over with Continue panelling beyond
screen direct fixed to wall face concealing existing duct to slab edge
0
concealed fascia gutter upstand wall on ground level
30
Feature batten wall
cladding to new wall
concealing existing duct
Existing
Male WC
DP
COL
Line of existing slab Existing walkway planters
over shown dotted to be reconfigured / Suite 2,
added to suit substation Cnr Gard
doors and gates
Alexand
Existing Substation
Female WC PO Box
P 07 54
llis
Tre
admin@
Existing amenities
to be retained
SUNCOAST RESORT BUSINESS CENTRE
SUITE 2 CNR GARDAK ST & SURF RD
ALEXANDRA HEADLAND Qld 4572
PO BOX 6232 MAROOCHYDORE BC Qld 4558
PH : 07 5443 5028 FAX:07 5479 2380
ABN 23 123 917 724
EMAIL: [email protected]
Switch
Room project
PROPOSED ALTERATIONS &
ADDITIONS TO EXISTING
RESORT BUILDING
for
KEX
Existing stair to be retained.
COL NETANYA RESORT
Provide new balustrade
up
Sta Downpipe to be concealed
ir and screen enclosure plus within structural column, to at
DP
gate as per future detail future detail, T.B.C. 75 HASTINGS STREET
dn
NOOSA HEADS
Plant Gate
0
30
COL Gate drawing
70
DETAILED AREA - 'SAILS'
11
100 x 25 powdercoated aluminium
ENTRY / PARK ROAD
AC
AC screen and gate to future detail
FRONTAGE
up
Sta
ir
Remove existing water
AS SHOWN
dn
feature and planter section.
Provide new entry / exit date 14/04/2020 drawn JP scale @A1
Gate gate and fire escape stair
00
drawing no. 19021 SD60.08 revision D
12
0
25
Copyright of this document remains the exclusive
N
property of SPROUT ARCHITECTS PTY LTD
ABN 23 123 917 724.
GROUND LEVEL EAST ELEVATION Contractors are to verify all dimensions and levels on
site prior to commencing. Report all discrepancies to
the Architect. Use figured dimensions in preference
Scale 1:50 Scale 1:50 0 5 10 to scaled.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
Att 1_Architectural Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 64.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.