Appendix H. Planning Scheme Code Responses

Attached to the e-mail Retail Bus Type 5 & Type 2 & Op Works Economic Report & PScheme Code Response - MCU17/0572 & OPW17/0611.

of 69

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                                                                                                                                                           NOOSAVILE LOCALITY CODE
                                                                                                                                           Performance Criteria and Acceptable Solutions



                                                                                                                                                                            COUNCIL USE
             SPECIFIC OUTCOMES                              PROBABLE SOLUTIONS                     SOLUTIONS*                        COMMENTS
                                                                                                                                                                               ONLY
       i.   for the Attached Housing Zone 2              Russell St, William St and Howard St,                  proposed).
            storeys unless located on property           or Weyba Rd, James St and Albert St
            with frontage to the following               north of their intersections with
            streets: - Russell St, William St and        Elizabeth St where they have a
            Howard St, or Weyba Rd, James St             maximum building height of 12m;
            and Albert St north of their            b)   if in the Visitor Mixed Use Zone – 12m;
            intersections with Elizabeth St,        c)   if in the Business Centre or Industry
            where they are not to exceed a               Zones — 10m;
            maximum building height of 3            d)   if in the Shire Business Centre Zone –
            storeys;                                     8m, except in Precinct E1 or E2 where
       ii. for the Visitor Mixed Use Zone– 3             12m;
            storeys, although present only 1-2      e)   if in the Industry Zone – 10m
            storey façades to Gympie Terrace;       f)   in all other zones—8m.
       iii. for the Shire Business Centre
            Zone– 2 storeys, except in Precinct
            E1 and E2 where 3 storeys and
            Precinct REC/MU where 1 storey;
            and
       iv. for all other zones— 2 storeys;
    c) do not visually dominate the street or
       surrounding spaces;
    d) preserve the amenity of surrounding
       land;     ensure     that    development
       responds to the site topography; and
    e) are well articulated with strong
       horizontal and vertical design elements
       to provide an interesting streetscape
       and to complement landform changes
       and landscapes.

    Setbacks                                                                                                   Complies with Specific Outcome
    O8                                              S8.1                                                        The proposed development complies with the setbacks
    Buildings and other structures are              Buildings and structures comply with the                    identified in Schedule 1 - Minimum Boundary Setbacks,
    appropriately designed and sited to—            setbacks identified in Schedule 1 -                         being in excess of the 6m setback from the street
    a) provide amenity for users of the             Minimum Boundary Setbacks.                                  frontage for the building component and an allowance to
        premises as well as preserve the visual                                                                 build to the western boundary recognising the adjoining
        and acoustic amenity of adjoining and                                                                   property is also situated within the Industry zone. It is
        nearby land uses;                                                                                       recognised that the roof structure of the fuel bowsers is
1       Solution:  = Acceptable Solution                                                                                                                                      Appendix H
                  A/S = Alternative Solution
                  N/A = Not applicable to this proposal

PR137996-1                                                                                                                                                                        Page 4
Log in to download the original file

Appendix H. Planning Scheme Code Responses.pdf · 1.1 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.