Appendix H. Planning Scheme Code Responses
Attached to the e-mail Retail Bus Type 5 & Type 2 & Op Works Economic Report & PScheme Code Response - MCU17/0572 & OPW17/0611.
LANDSCAPING CODE
Performance Criteria and Acceptable Solutions
O5 The provision of landscaping is to a S5.1 Landscaping provided which allows ✓ Complies with probable solution
satisfactory standard ensuring that it does adequate visibility for casual surveillance Targeted landscaped pockets at the sites periphery
not lead to opportunities for concealment of public and semi-public spaces, including provides for adequate visibility enabling casual
and possible assault sites entrances and exits to sites and buildings, surveillance. Please refer to the Landscape Concept
by: Plan provided at Appendix E.
(a) planting trees which have clean trunks
to a height of at least 1.8 m; and
(b) appropriately spacing shrubs at 1.2m
horizontal centres, with a maximum
height of 0.75m, to avoid clumping and
to retain sightlines.
O6 Street trees and plantings in towns and S6.1 Street trees and trees in carparking ✓ Able to Comply with probable solutions
villages, carparks and other areas where areas achieve a maximum of 900mm clear Please refer to the Landscape Concept Plan provided
potential conflicts with vehicles and trunk height for a 2.0m high tree at planting at Appendix E, further details will be provided at the
pedestrians are evident, are planted so as and are able to attain a clear trunk height Operational Works phase.
to maximise vehicle and pedestrian safety. of 1900mm on maturity;
S6.2 All scrub planting to be a maximum ✓ Able to Comply with probable solution
height of 700mm from the road pavement Please refer to the Landscape Concept Plan provided
(not top of kerb). at Appendix E, demonstrating scrub plantings can
achieve compliance with S6.2
Services and utilities N/A Not applicable
O7 All landscaping works maintain S7.1 Plant species used in landscaping
adequate safe distance from services and adjacent to substations, or adjacent to or
utilities including substations, overhead on electricity transmission line easements,
powerlines, power poles and transformers, are less than 4m high at maturity and do
street lamps, stormwater catchment pits, not encroach within 3m of a substation
and underground services and utilities. boundary;
OR
S7.2 For trees higher than 4m, trees are ✓ Able to Comply with probable solution
planted at a distance from any part of an Please refer to the Landscape Concept Plan provided
electricity transmission line at least equal at Appendix E, further details will be provided at the
to the expected height of the tree at Operational Works phase
maturity (see Figure 14-17);
Figure 14-17