3(%%/(&5(7(
&21&5(7(
' ' '
' ' [
[ [ [ [
127(
(PHUJHQF\OLIWRIIKLQJHVWRDOOZF V
0HFKDQFLDOYHQWLODWLRQWRDOO%DWKURRPVDQG(QVXLWHV
$OOGHPROLVKHGPDWHULDOLQFOXGLQJUXEEOHDOOWUHHSDUWVDQG
EXLOGLQJSURGXFWVWREHUHPRYHGIURPVLWHDQGGLVSRVHGRILQ
DFFRUGDQFHZLWKORFDODXWKRULWLHV
$OOZRUNPDQVKLSDQGPDWHULDOWREHLQDFFRUGDQFHZLWKWKH
ODWHVWEXLOGLQJUHJXODWLRQVDQGUHOHYDQWFRGHVDQGVWDQGDUGV
LQFOXGLQJDPHQGPHQWVDQGWRPDQXIDFWXUHU VVSHFLILFDWLRQV
&KHFNUZSUHTXLUHPHQWVIRUHDFKUHJLRQDVVKRZQDUH
VXJJHVWHGRQO\
%XLOGHUWRHQVXUHDOOSODQVDUHLQFRPSOLDQFHZLWK
$XVWUDOLDQ6WDQGDUGVDQG%XLOGLQJ&RGHV
3URYLGH6DIHW\*ODVVWREDWKURRPVDQGRWKHUDUHDVZKHUH
UHTXLUHG
3LSHDOOVWRUPZDWHUIURPURRIWR5DLQZDWHUWDQN
6PRNHDODUPVWREHKDUGZLUHGLQDFFRGDQFHZLWK
UHOHYDQWFRGHVDQGVWDQGDUGV 3URSRVHG6KHG
'
[
.(<
+7 +26(7$3
EDUQGRRU
)* )/225*8//<
'2:13,3(
'3
&6'
' '225
&6' &$9,7<6/,',1*'225 ZFVKRZHU
: :,1'2:
5+ 5$,1+($'
63 63,77(5
&65 &2/25%21' OLQHRIURRIRYHU
6+((7522)
6: 67250:$7(5
6 602.($/$50 5(7$,1,1*:$//'(7(50,1((;7(17216,7( $
+: +27:$7(5 $
)
1
)5,'*(
)/$7522)
)/5
&/,3/2&.25
6,0,/$5
3' 3/80%,1*'8&7
)$//',5(&7,21
$& $,5&21',7,21(5
81,7
&(,/,1*)$1
352326('6+(' )/2253/$1
6&$/(
3UHOLPLQDU\
'5$:,1*7,7/(
*(1(5$/127(6 &/,(171$0( -R9DQ2V
8VHZULWWHQGLPHQVLRQVRQO\'2127VFDOHGUDZLQJV&RQWUDFWRUVWRYHULI\DOO 6KHG )ORRU3ODQ 6,7($''5(66 3RPRQD.LQ.LQ5RDG.LQ.LQ
GLPHQVLRQVDQGOHYHOVRQVLWHSULRUWRFRPPHQFLQJZRUNVDQGVKRSGUDZLQJV
6LWHORFDWLRQLV&DWHJRU\1RUWRHQJLQHHU VUHTXLUHPHQWV
7KHVHGUDZLQJVDUHWREHUHDGLQFRQMXQFWLRQZLWKHQJLQHHU VGHVLJQDQG '5$:,1*1R
$
,668( &
'$7( '$7( )HE
GHWDLOVWKHDFFRPSDQ\LQJEXLOGLQJVSHFLILFDWLRQDQGVFKHGXOHRIILQLVKHV
3KZZZQDWDQLGHVLJQFRPTEFF 6&$/( 6+((76,=( $
,ILQGRXEWSOHDVHUHTXHVWFODULILFDWLRQ'2127$6680(
[OCR of page images]
NoTE:
41. Emergency if off hinges to all we's,
2. Mechancial ventilation to all Bathrooms and Ensuites.
3. Alldemolished material including rubble, al ree parts and
building products to be removed from site and disposed of in
accordance with local authorities.
5. All workmanship and material to be in accordance with the
latest building regulations and relevant codes and standards
including amendments and to manufacturer's specifications.
6. Check rwp requirements for each region, as shown are
suggested only.
7. Builder to ensure all plans are in compliance with
Australian Standards and Building Codes.
8. Provide Safety Glass to bathrooms and other areas where
required.
9. Pipe all stormwater from roof to Rainwater tank.
40. Smoke alarms to be hard wired in accodance with
relevant codes and standards.
KEY
HTg@ HOSE TAP
FG FLOOR GULLY
oa
DOWN PIPE
DP
D DOOR
csD
W WINDOW
CAVITY SLIDING DOOR
[J RH RAIN HEAD
sp SPITTER
CSR COLORBOND
SHEET ROOF
SW STORMWATER
So SMOKE ALARM
HW HOT WATER
F FRIDGE
FLAT ROOF
FLR CLIP LOCK OR
SIMILAR
PD — PLUMBING DUCT
FALL DIRECTION
AIR-CONDITIONER
UNIT
CEILING FAN
natani design
ESKerL oe VM TEB KSEE Asie
Ce
1900
4930
—
20070
| Dos
T
ni 920 cD
Dos
L 5000 L 5000 L 5000 L 5000 L 5000 L
7 7 7 7 7 7
L 25000
PROPOSED SHED (1) FLOOR PLAN
SCALE: 1:10
o
250,
aa
3000)
10000
liminary
GENERAL NOTES:
Use written dimensions only. DO NOT scale drawings. Contractors to verify all
dimensions and levels on site prior to commencing works and shop drawings.
Site location is Category N3 or to engineer's requirements.
These drawings are to be read in conjunction with engineer's design and
details, the accompanying building specification and schedule of finishes.
If in doubt, please request clarification. DO NOT ASSUME.
iG TITLE:
“Shed (1) Floor Plan
CLIENT NAME: Jo Van Os
SITE ADDRESS: 921 Pomona Kin Kin Road, Kin Kin
ISSUE:C
DATE: 22/06/2026
DATE: Feb 2026
scale: 1:200 | sHeersize: A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
proposal plans caretaker osco pdf.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.8 MB (small file)
- File type
No other editions are linked here.