Council archive · source document
Craven Duplex BA01_Rev A · MCU17/0565
Attached to the e-mail Duplex & Op Works - MCU17/0565 & OPW17/0599 -PAYMENT LINK SENT AWAITING OWNERS CONSENT.
4.2
1
5.1 SMH
1 359° 58' 20" 24.90 m
1500
2000
2500
DP DP
G3
DP
TR
ROBE
7 6 5 4 3 2 1 VB BED 3
UP CPT
DP
DP
TR BATH
DECK TILE
SHF
LIVING
65
TIM SHR
HALL
°0
6000
4.2
TIM BED 2 2
0' 4
LINEN CPT
LC
a d
0"
G4
ROBE
UNIT 2
STAIR 2
17
TIM
.5 4
MEALS STAIR 1 UP
WC WC
TIM
m
TIM VB TILE
BIN 9 8
o
SK DW 11 10
14 13 12 3 2 1
16 15 5 4
KITCHEN 15
00
TIM 8
BED 2
ROBE
9
R
HP MW PTRY 13 12
11 10
2 1
POOL WO 16 15
14
6 5 4 3
UP CPT
FR LC A
STAIR 2
269° 58' 20" 19.78 m
MW PTRY
WO TIM 5.1
STAIR 1
HP TIM LINEN HALL
KITCHEN TIM
e
TIM MEALS SHR
DW
BIN TIM
SK
g
UNIT 1 BED 3
POOL VB BATH CPT
TILE WC
ROBE
SHF
d
HB TILE PIER
1 TR
4.1
45
00
WC m
LIVING 00
TIM 4.
e
DP
0"
G2
'2
DP 44 SMH
3°
A
k
5.1 DECK 14
DP
P a r
DP
253
450
° 46
0
4 m
5.1
' 0 0"
0 " 1
° 1 4' 0
2.95
158
4500
2
m
22
1° 4.1
21
'0
0" t
2.
95 G1
0" 9.14
m e
m 172° 43
'3
r e
188° 56' 0
0" 2.95 m
SMH
1 t
5.1 S
n
a
r y
B
north
LEVEL 1
1 : 100 0 1 2 3 4m
1:100
GENERAL NOTES TO BUILDER sheet title:
Proposed New Housing: ABBREVIATION LEGEND PRELIMINARY - NOT FOR CONSTRUCTION
-contractor to confirm all dimensions,
M Design © COPYRIGHT 2017 - M DESIGN levels and site conditions including LT LAUNDRY TUB HP HOT PLATE
PO Box 290 THE IDEAS AND CONCEPTS CONTAINED location of existing services on site prior WM WASHING MACHINE, BY OTHERS FR REFRIGERATOR FLOOR PLAN - LEVEL 1
to the commencement of any works. For: REV DESCRIPTION DATE
Peregian Beach QLD 4573 WITHIN THIS DOCUMENT AND THE -do not scale from drawings. DRY CLOTHES DRYER, BY OTHERS DW DISHWASHER
B COUNCIL APPROVAL 16.10.17
DOCUMENT ITSELF REMAIN THE LC LAUNDRY CHUTE col COLUMN, TO STRUCT ENGINEERS DETAILS
INTELLECTUAL PROPERTY OF M DESIGN
AND MAY NOT BE COPIED OR
-dimensions take precedent over scale
-drawings to be read in association with
specification and schedules of finishes
Craven SHR
VB
SHOWER
VANITY BASIN
DP
GU
DOWNPIPE
GUTTER, TO HYD ENGINEERS DETAILS
job no:
1723
drawn by:
LBW
REPRODUCED IN PART OR IN WHOLE HB HAND BASIN BAL 1 BALUSTRADE, TYPE TBC
-refer SOW for all door and window hardware details
WITHOUT EXPRESSED WRITTEN date:
-waterproofing of wet areas to be in Project Address: MR MIRROR BAL 2 BALUSTRADE, TYPE TBC
BSA No. 1066058
PERMISSION FROM MICHAEL BROEREN
accordance with section 3.8 of the B.C.A TR TOWEL RAIL SCR SCREEN 14.10.16
OF M DESIGN.
-all tiles to wet areas to be non slip WC WATER CLOSET CL CLOTHES LINE
Contact: Michael Broeren
-lift off hinges to all wet area doors 7 Parkedge Road, Sunshine Beach QLD SG SHOWER GRATE MB METER BOX scale (A2): drawing no:
t. 07 5471 2721
t. 0422 969 645
-ceiling and wall insulation as per standard
gov. specifications
SK SINK SMH SEWER MANHOLE 1 : 100 2.2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.