Original source · versioned page text
Att3 - Bushfire Report
Very large file (10.0 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Bushfire Hazard Assessment & Management Plan v1 NCES REF: J001061
Lot 7 on RP216403, Lot 394 on M371117, and Lot 650 on M37380 – 48-59 Kabi Road, Cootharaba
6 AUSTRALIAN STANDARD 3959:2018 CONSTRUCTION OF BUILDINGS IN
BUSHFIRE PRONE AREAS (AS 3959:2018) SETBACKS
In general, the southern and eastern portions of the site are mapped within the Bushfire
Hazard Overlay in the Noosa Plan 2020 (refer Plate 21) and SPP Bushfire Hazard Overlay
Map (refer Plate 1).
Plate 21 – Asset Protection Zones
Building works within land which has been designated under a power of legislation as being
subject, or likely to be subject, to bushfires triggers building design assessment under AS
3959:2018 (NCC 2019).
The Standard provides minimum construction requirements for new habitable dwellings and
habitable building alterations in designated Bushfire Prone Areas. The construction
requirements are intended to improve the performance of buildings subjected to burning
debris, radiant heat or flame contact. Building works in Designated Bushfire Prone Areas must
be built to the Bushfire Attack Level (BAL) construction standard relevant to the building site
as identified by the AS 3959:2018 methodology.
In this instance, it is noted that all of the proposed Class 1 buildings (i.e., the three villages)
are located outside of the mapped extent on both the Noosa Council and State Planning Policy
designated Bushfire Prone Areas. Proposed building works located outside of these mapped
areas are not required to be built to satisfy AS 3959.