aZg E DeNova Group Pty Ltd Tel 03 9848 8777 O V A Suite 9, First Floor Fax 03 9848 8755 857-859 Doncaster Road [email protected] RO P Doncaster East Vic 3109 www.denovagroup.com.au ABN 88 127 073 295 ACN 007 023 510 PO Box 141 Tewantin QLD ¥ 4 Att: Mr Daniel email: [email protected] 30" August 2007 Dear Daniel, RE: Planning Application File No 07/1586 For Caloundra Building Approvals 6 The Promontory Noosaville Lot 847 SP!102579 Further to your letter dated 22.08.07 and our subsequent phone conversation, to follow our response to point 3 together with the acid sulphate report prepared by Soil Surveys P/L 307-2624 to address points | & 2 of your letter. tem 3 Outcome |2 We do not propose altering the architectural detailing of the proposal it is our assertion that the design has generally achieved the intent of the outcome and therefore an acceptable solution, our reasons being as follows: The design of the proposed dwelling will complement the existing street scape and sit in harmony within the Noosa Waters architectural style. The size of the building, its shape, use of materials and proportions reflect that of the surrounding dwellings and contribute positively to the local sky line. Noosa Waters has a variety of styles consisting of conventional pitched roofs and more recently, a more contemporary style has evolved consisting of low pitched roofs with parapets. The style of this proposal is in keeping with the direction of the latter, to that end | have attached photographic examples of several homes within the immediate vicinity as examples of the evolving Noosa architecture, including the adjoining dwelling to the East. The proposal contains all elements of the more contemporary design and consists of low pitched roofs, some parapet walls, eye lid eave details, natural rock walls, large expanses of glass, rendered walls, large terraces encompassing the Noosa lifestyle of indoor and outdoor living, cross natural ventilation and open plan design. All resulting in an appropriate design style that is in keeping with the Noosa design.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 33 pages
Page 2
a The building presents a combination of traditional eave and eye lid eave detailing combined with some parapet walling to provide architectural detailing and variation interest in height and depth of the various wall and glass elements, resulting in a non-bulk design. Large lengths of conventional eave detailing have been incorporated on all four elevations with even greater emphasis to both the adjoining neighbouring properties. Should you have any queries regarding the above, wish to discuss the application further or require further submission to allow approval of our application, please do not hesitate to contact me. zirkas cc, Andrew Stewart (Caloundra Buildings Approvals P/L) Adam Graham (De Nova Group P/L)
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
JL, aw SOIL SURVEYS ACID SULFATE SOIL INVESTIGATION & MANAGEMENT PROJECT NO. 307 - 2624 AUGUST 2007 DENOVA GROUP PROPOSED RESIDENCE 6 THE PROMONTORY NOOSA WATERS OFFICES IN BRISBANE, GOLD COAST AND SUNSHINE COAST
Page 10
TABLE OF CONTENTS 1.0 INTRODUCTION 5.1 Preliminary Screening Tests 5.2 Quantitative Tests 6.0 ACID SULFATE SOIL ASSESSMENT & MANAGEMENT 6.1 Acid Neutralisation §.2 Site Monitoring ee ee 7.0 LIMITATIONS APPENDICES A Borehole Records B Laboratory Test Results c Borehole Layout Plan
Page 11
* Project No. 307-2624 Page 1 August, 2007 1.0 2.0 INTRODUCTION This report presents the results of an acid sulfate soil (ASS) investigation, and makes recommendations for the management of ASS for the proposed residence at 6 The Promontory, Noosa Waters. The fieldwork for the investigation was conducted by Soil Surveys Engineering, and with laboratory testing carried out by Soil & Water Laboratories (also part of the Soil Surveys Group). The proposed development is to consist of a new 2 storey residential building, which is understood to be of masonry and suspended concrete slab construction. The development is to also include a boatshed and storage room accommodated in a semi-basement with the basement floor level set approximately 2.2m below the existing ground surface. Soil Surveys Engineering Pty Limited have been commissioned to among other things, assess the results of the acid sulfate soil investigation and laboratory testing and to provide recommendations for the management of acid sulfate soils for this project. This report presents the first phase of site investigation for this project, and we note that a second phase of investigation will be carried out at a later time, which will address the geotechnica! design requirements for this project. SCOPE OF GEOTECHNICAL SERVICES The scope of geotechnical services provided by Soil Surveys Engineering Pty. Limited is to include the following items, as detailed in our proposal 307-2634 dated 2nd August 2007. « Assessment of data which includes borehole logs, pHr/pHrox screening tests, and quantitative laboratory test results. ¢ Identification of acid sulfate soils (ASS) present. *« Recommendation of suitable management strategy for the acid sulfate soils. F SOIL SURVEYS ENGINEERING
Page 12
“ Project No. 307-2624 Page 2 August, 2007 3.0 SITE DESCRIPTION The site for the proposed residence is located on the southern side of The Promontory in Noosa Waters estate, Noosaville and is described as being generally level but with a sloping section falling towards the Noosa Waters cana! at the rear of the block. At the time of the investigation fieldwork, the site was occupied by an existing double storey residence of masonry construction, and the surrounding garden included grass and small to medium size shrubs, and some ornamental trees. It is understood that the building is to be demolished. 4.0 GEOTECHNICAL INVESTIGATION 4.1 Field Investigation Subsurface conditions at the site were investigated by drilling 2 No. boreholes to depths of 6.0m to 7.5m. Both boreholes were carried out near the front of the property, due to the restricted access conditions, and a plan showing these locations is included in Appendix C. Disturbed samples were taken at 0.25m intervals down to a depth of 3.0m in both boreholes, for the purposes of acid sulfate soil testing. The soil classification descriptions and field testing were carried out by Soil Surveys Engineering, and these were in general accordance with the following:- ° AS.1726 - 1993 Geotechnical Site Investigations . AS.1289 Methods of Testing Soils for Engineering Purposes The laboratory testing was carried out by Soil & Water Laboratories, who have NATA Registration for the acid sulfate soil testing procedures. in addition, this report makes reference to, and our recommendations are generally in accordance with the following acid sulfate soils regulatory and guidance documentation: ° Queensland Acid Sulfate Soils Investigation Team (QASSIT) “Guidelines for Sampling and Analysis of Lowland Acid Sulfate Soils (ASS) in Queensland” October 1980. ° Queenstand Acid Sulfate Soil Technical Manuat - Soil Management Guidelines ZZ SOIL SURVEYS ENGINEERING
Page 13
* Project No. 307-2624 Page 3 August, 2007 . State Planning Policy 2/02 Guideline Planning and Managing Development Involving Acid Sulfate Soils The detailed borehole record sheets are included in the Appendix A. 4.2. Subsurface Conditions 5.0 The subsurface profile encounted by the boreholes consisted of a surface layer of gravelly sand or silty sand fill overlying natural silty sand. The surface layer of silty sand fill is described in the borehole logs as fine to coarse grained, mostly grey or grey brown, and with little or no fines and a trace of organics in some parts. The layer of silty sand fill extended from the surface to 0.6 - 0.7m depth in the boreholes. The natural sand encountered below the surface fill, is inferred to be alluvial and is described in the logs as fine to medium grained, and mostly pale grey with some bands of dark grey. LABORATORY TESTING Two stages of laboratory testing were undertaken for this project. 5.1 Preliminary Screening Tests The first stage consisted of the initial qualitative screening of the disturbed samples, conducted using the field pH (pHr) and oxidised (pHrox) test method, and this was carried out by Soil & Water Laboratories (SWL), on each of the disturbed samples. This is a quick, qualitative assessment of the potential acidity of the soil. The results of these screening tests were used to select which of the soil samples should be further assessed by quantitative laboratory testing. Laboratory test results for the pH- / pHrox screening are presented in Appendix B, and the measured values in the this screening (23 No. sets in total) were seen to vary within the following ranges. ¢ pHr 5.8 to 6.6 (mean value = 6.2) © pHeox 3.3 to 5.0 (mean value = 4.1) ¢ pHr-pHrox 1.4 to 3.3 (mean value = 2.1) F SOIL SURVEYS ENGINEERING
Page 14
* Project No. 307-2624 August, 2007 Page 4 _5.2 Quantitative Tests The second stage of laboratory testing was carried out by SWL on 4 No. samples, which were selected on the basis of the screening tests showing the possible presence of acid sulphate soil, i.e. those showing low pH and large change between the pHr and the PHrox readings. This second stage testing consisted of Chromium Reducible Sulfur (SCr) tests, and Total Actual Acid (TAA) tests. The SCr test provides data on sulfuric acids, without influence from organic acids, and is generally indicated for low acidic sandy soils and/or soils with some organic material. Full results of the testing are summarised below in Table 1, and the SWL test report sheets are included in Appendix B TABLE 1 QUANTITATIVE TEST RESULTS SUMMARY Borehole ID Sample Depth Description Sa TAA (m) (%S) (mol H+/t) BH1 2.0 - 2.25 Silty Sand 0.01 4 (light grey) BH2 1.0- 1.25 Silty Sand 0.00 2 (light grey) BH2 1.75 -2.0 Silty Sand 0.02 13 (dark grey) BH2 2.75 - 3.0 " 0.07 42 ZZ SOIL SURVEYS ENGINEERING
Page 15
* Project No. 307-2624 Page 5 August, 2007 6.0 ACID SULFATE SOIL ASSESSMENT & MANAGEMENT The ASS regulatory and guidance documentation (refer Section 4.1) for management of acid sulfate soils has defined action levels for the quantitative test results, and these are used to assess the need for an ASSMP. The following action criteria apply:- * TAA - 18 mol H*/tonne * Scr (%) - 0.03% It is noted that the above action levels apply to the combined Scr and TAA results, which should be added together (in like units). It is seen that only one sample returned a combined value exceeding the action level of 0.03 %S by weight, or 18 mol H+/tonne. This sample was taken from borehole BH2 at 2.75 - 3.0m depth, was described as dark grey silty sand, and it was shown to contain potential acid suifate soil only, with no actual acid. Given the action level is exceeded by this sample, under the regulatory framework set down in the referenced documentation, it is necessary that an acid sulfate soil management plan (ASSMP) be established. This management plan would be executed to ensure that the excavation operations are carried out in such a way as to limit or avoid any adverse environmental or infrastructure impacts. However, we note that its implementation can be viewed as precautionary, since the sample exceeding the action level for ASS was taken from below the expected maximum excavation depth. 6.1 Acid Neutralisation It is anticipated that the excavated material removed during the construction would be disposed possibly by one or both of two methods. The excavated material could be used for landscaping purposes on site, or as fill material to be used on other earthworks and construction sites in the region. Current experience indicates that the most effective method for limiting or preventing the adverse consequences of acid release from the excavated actual or potential ASS material, is by the controlled application of a suitable neutralising agent to the excavated soil. Z SOIL SURVEYS ENGINEERING
Page 16
* Project No. 307-2624 Page 6 August, 2007 Various neutralising agents are available, however agricultural lime or “aglime" (CaCOs) is considered to be the most suitable, being the most widely available and least hazardous product for acid sulfate soil treatment. The application of aglime to the soil requires thorough mixing and incorporation into the soil. As a general approach it is recommended that careful supervision and control of the excavations are carried out. Further, that sampling and testing of the materials should be carried out during excavation, to confirm the effectiveness of the acid neutralisation. The appropriate application rate for the aglime is calculated using the formula presented in ASS Tip 13 in the Queensland Acid Sulfate Soi! Technical Manual - Soil Management Guidelines, where the rate of CaCQs; in kg/tonne is calculated as 46.8 x %S (Scr) or 0.075 x mol H*/tonne (TAA). This rate incorporates a 1.5 factor of safety on the quantity of aglime. It is calculated that neutralisation of the excavated silty sand at this site should be carried out with aglime applied at a rate of 3.5kg/tonne, which is equivalent to 5kg/m*(with a dry density of soil = 1.5tonne/m*). It is recommended that the acid neutralisation procedure incorporate the following measures to ensure an effective result is achieved:- * Only aglime (CaCOs) should be used, as quick lime (CaO) or slaked lime (Ca(OH)2) are not considered viable or safe long-term neutralising agents of acidic soil. « The recommended lime dosing rates refer to a 100% pure lime product. The actual liming rates would need to be factored according to the product's quoted neutralising value in order to reach the ideal neutralising capacity. * The aglime should be fine grained to ensure better mixing and decreased chance of acid leachate runoff occurring. * The aglime should be thoroughly mixed with the acidic soil prior to disposal or re-use. The recommended design liming rate is calculated to neutralise the recorded worst case acid sulfate soil as revealed by the sampling and testing. As noted above, treating the excavated soil from this site with aglime at the above rate can be considered a precautionary procedure; since the worst (and only) case acid sulfate soil sample was retrieved from below the expected maximum depth of excavation. ZF SOIL SURVEYS ENGINEERING
Page 17
* Project No. 307-2624 Page 7 August, 2007 Given the limited extent of the proposed excavation works, it is recommended that the application of aglime be carried out using the simple surface treatment method. This method involves applying the aglime to the ground surface in the area of the excavation, prior to its commencement. The amount of lime applied on the surface in this manner should be appropriate for the depth of the excavation. That is, if excavation to 1.5m depth was required and using the rate of 5kg/m®, then a surface layer of 1.5m x 5kg/m? = 7.5 kg/m? should be applied. The mixing of lime with the excavated soil would then be achieved during the excavation, handling and transport processes. It is also noted that if the excavation is to be staged, then the amount of lime spread over the surface may need to be adjusted accordingly, or be reapplied over a lower benched level. By adopting the recommended surface treatment of aglime, the management of the acid sulfate sulfate soil occurring at this site can be effectively finalised within the single activity. Other ASS management issues such as site runoff, catchponds, groundwater monitoring, staging of excavation works and ASS treatment, stockpiles of untreated ASS, and the sampling and monitoring of treated ASS, are all either inapplicable or are simplified to the extent where they are resolved and finalised within the single ASS treatment/verification site activity. 6.2 Site Monitoring A simple monitoring program should be conducted to verify the effectiveness of the management strategy. Considering the relatively low required application rate of lime, and the limited extent of the affected soil, it is recommended that the ASS monitoring simply consist of verification testing using the acid neutralising capacity (ANC) test procedure, of the treated soil at the rate of 1 test per 500m°. It is also recommended that in the event that extraction of groundwater is required during the basement construction, the acidity and turbidity of the groundwater should be checked, and these water quality criteria must be at acceptable levels prior to discharge. We note that the results of a pre-construction groundwater monitoring program should also be considered when establishing water quality criteria in relation to discharge of extracted groundwater. ZB SOIL SURVEYS ENGINEERING
Page 18
Project No. 307-2624 Page 8 August, 2007 7.0 LIMITATIONS We have prepared this report for use by DeNova Group for acid sulfate management purposes in accordance with currently accepted environmental and gectechnical guidelines. No other warranty, expressed or implied, is made as to the professional advice included in this report. This report has not been prepared for use by parties other than DeNova Group or their associated clients or consultants. It may not contain sufficient information for the purposes of other parties or for other uses. STEPHEN GAMBLE (RPEQ 6644) for and on behaif of SOIL SURVEYS ENGINEERING PTY LIMITED ZSOIL SURVEYS ENGINEERING
Page 19
Project No. 307-2624 * August, 2007 APPENDICES ZF SOIL SURVEYS ENGINEERING
Page 20
NOTES RELATING TO THIS REPORT INTRODUCTION These notes are provided by Soil Surveys Engineering Pty Limited (the Company) to complement the geotechnical report in regard to classification methods and field procedures. Not all notes are necessarily relevant to all reports. The ground is a product of continuing natural and man-made processes and therefore exhibits a variety of characteristics and properties which vary from place to place and can change with time. Geotechnical engineering involves gathering and assimilating limited facts about these characteristics and properties in order to understand or predict the behaviour of the ground on a particular site under certain conditions. This report may contain such facts obtained by inspection, excavation, probing, sampling, testing or other means of investigation. If so, they are directly relevant only to the ground at the place where and at the time when the investigation was carried out. DESCRIPTION AND CLASSIFICATION METHODS Soils - The methods of description and classification of soils and rocks used in this report are based on Australian Standard 1726-1993 (Geotechnical Site Investigations), where appropriate. In general, descriptions cover the following properties - soil or rock type, colour, strength or and structure, density, inclusions. Identification and classification of soil and tock involves judgement and the Company infers accuracy only to the extent that is common in current geotechnical practice. Soil types are described according to the dominant particle size and behaviour as set out in AS 1726-1993. Cohesive soils are classified on the basis of strength (consistency) either by use of hand penetrometer, shear vane, laboratory testing or engineering examination. AS1726-1993 Table A4. The strength terms are defined in Non-cohesive soils are classified on the basis of relative density usually based on insitu testing or engineering examination (see AS1726-1993 Table AS5). Rocks - Rock types are classified by their geological (AS1726-1993 Table Aé6), with names together Table 1 Estimated strength descriptions given to rock based on engineering examination | Strength Term Approximate Qu (MPa) Extremely Weak <1.0 Very Weak 1.0-5.0 Weak 5.0 - 25 Medium Strong 25 - 50 Strong 50 - 100 Very Strong 100 - 250 Extremely Strong > 250 Ref ISRM "Suggested Methods for the Quantitative Description of Discontinuities in Rock Masses” descriptive terms regarding weathering (AS1726-1993 Table AQ), strength (refer Table 1 below), defects (AS1726-1993 Table A10), etc. Where strength testing (ie Point Loads) AS1726-1993 Table A8& further is carried out, is used. Where relevant, information regarding rock classification is attached. SAMPLING Sampling is carried out during drilling or from other excavations to allow engineering examination (and laboratory testing where required) of the soil or rock. Disturbed samples taken during drilling provide information on plasticity, grain size, colour, moisture content, minor constituents and, depending upon sample disturbance, (information on strength and structure). Undisturbed samples are taken by pushing a thin walled sample tube, usually 50mm diameter (U50), into the soil and withdrawing it with a sample of the soil Such samples yield information on structure and strength, contained in a relatively undisturbed state. and are necessary for laboratory determination of shear strength, volume change potential and compressibility. _ Undisturbed sampling is generally effective only in cohesive soils. Details of the type and method of sampling used are given on the attached logs. NOTEREP.SAM SOIL SURVEYS ENGINEERING
Page 21
-2-
INVESTIGATION METHODS
The following is a brief summary of investigation
methods currently adopted by the Company and some
comments on their use and application.
Test Pits - These are normally excavated with a
backhoe or a tracked excavator, allowing close
examination of the insitu soils if it is safe to descend
into the pit. The depth of penetration is limited to about
3m for a backhoe and up to 6m for an excavator.
Limitations of test pits are the problems associated
with disturbance and difficulty of reinstatement and the
consequent effects on close-by structures. Care must
be taken if construction is to be carried out near test pit
locations to either properly recompact the backfill
during construction or to design and construct the
structure so as not to be adversely affected by poorly
compacted backfill at the test pit location.
A borehole of 50 to 100mm
advanced by manually
Hand Auger Drilling -
diameter is operated
equipment. Refusal of the augers can occur on a
variety of materials such as hard clay, gravel or rock
fragments and does not necessarily indicate rock level.
Continuous Spiral Flight Augers - The borehole is
advanced using 75 to 300 mm diameter continuous
spiral flight augers, which are withdrawn at intervals to
allow sampling or insitu testing. This is a relatively
economical means of drilling in clays and in sands
above the water table. Samples are returned to the
surface by the flights or may be collected after
withdrawal of the augers. Information from the drilling
{as distinct from specific sampling) is of relatively lower
reliability due to remoulding, inclusion of cuttings from
above or softening of samples by groundwater, or
uncertainties as to the original depth of the samples.
Augering below the groundwater table has a lower
reliability than augering above the water table. Various
drill bits are attached to the base of the augers during
the drilling. The depth of refusal of the different bit
types can provide information as to the strength of the
material encountered. Generally two different bit types
are used. The 'V' bit is a V shaped steel bit and the
‘TC’ bit is a tungsten carbide tipped screw type bit.
Wash Boring - The borehole is usually advanced by a
rotary bit with water or fluid pumped down the hollow
drill rods and returned up in the space between the
rods and the soil or casing, carrying the drill cuttings.
Only major changes in stratification can be determined
from the cuttings, together with some information from
“feel” and rate of penetration. More accurate
information on soil strata is gained by regular testing
and sampling using the Standard Penetration Test
(SPT) and undisturbed thin walled tube samples (U50).
Mud_ Stabilized Drilling - Either Wash Boring or
Continuous Core Drilling can use drilling mud as a
circulating fluid to stabilize the borehole. The term
"mud" encompasses a range of products ranging from
bentonite to polymers such as Revert or Biogel. The
tends to mask reliable
mud the cuttings and
identification is only possible from regular intact
sampling (eg. from SPT and U50 samples) or from
rock coring, etc.
Continuous Core Drilling - A continuous core sample
is obtained using a diamond or tungsten carbide
tipped core barrel. Provided fuil core recovery is
achieved (which is not always possible in very weak
rocks and granular soils), this technique provides a
In rocks, NMLC
coring (nominal 52 mm diameter) is usually used with
very reliable method of investigation.
water flush. The length of core recovered is compared
to the length drilled and any length not recovered is
shown as CORE LOSS. The location of losses is
determined on site by the supervisor. If the location of
the loss is uncertain, it is placed at the top end of the
tun, when the core is placed in a storage tray and
recorded on the tog.
Standard Penetration Tests - Standard Penetration
Tests (SPT) are used mainly in non-cohesive soils, but
can also be used in cohesive soils, as a means of
indicating density or strength. The test procedure is
described in Australian Standard 1289, "Methods of
Testing Soils for Engineering Purposes” - Test 6.3.1.
The test is carried out in a borehole by driving a 50mm
diameter split sample tube with a tapered shoe, under
the impact of a 63 kg hammer with a free fall of 760
mm. It is normal for the tube to be driven in three
successive 150 mm increments and the 'N' value is
taken as the number of blows for the last 300 mm, the
upper 150 mm being neglected due to possible
disturbance from the drilling method. In dense sands,
very hard clays or weak rock, the full 450 mm
NOTEREP.SAM
SOIL SURVEYS ENGINEERING
Page 22
-3- penetration may not be practicable and the test is discontinued at a reduced penetration. In the case where full penetration is obtained with successive blow counts for each 150 mm of, say 4, 6 and 7 blows, the record shows, 4,6,7 N=13 In a case where the test is discontinued short of full penetration, say after 15 blows for the first 150 mm and 30 blows for the next 40 mm, the record shows: 15, 30/40mm The results of the test can be related empirically to the engineering properties of the soil. Occasionally, the drop hammer is used to drive 50mm diameter thin walled sample tubes (U50) in clays. In such circumstances, it is noted on the borehole logs. A modification to the SPT test is where the same driving system is used with a solid 60° tipped steel cone of the same diameter as the SPT hollow sampler. The solid cone can be continuously driven for some distance in soft clays or loose sands, or may be used where damage would otherwise occur to the SPT. The tesults of this Solid SPT are shown as "N." on the borehole logs, together with the number of blows per 150 mm penetration. Cone Penetration Tests - Test Method - Cone Penetration Tests (CPT) are carried out in accordance with AS 1289 Test 6.5.1-1977, using an electrical friction-cone penetrometer. The test essentially comprises the measurement of resistance to penetration of a cone of 35.7 mm diameter pushed into the soil at a rate of 10-20 mm per The penetration is recorded in terms of pressure on the end second by hydraulic force. resistance to area of the cone (cone resistance, q., in MPa) and friction on the side of the 135 mm long sleeve immediately above the top of the cone (friction resistance, f,, in kPa). These forces are measured by electrical transducers (strain gauges) within the cone device. The ratio between friction resistance and cone resistance is also calculated as a percentage, ie.- Friction Ratio (FR) = re rasistanse'asPaT The friction ratio, FR, is generally low in sands (less than 1% of 2%) and generally higher in clays (say 3% or more). The interpretation of sandy clays, clayey sands and material with a high silt content is more difficult, but intermediate values (between 1% and 3%) would be expected. Highly organic clays and peats generally have a friction ratio in excess of 5%. Static cone data is recorded in the field on disc for later presentation using computer aided drafting. The equipment can be operated from any conventional drill rig. A total applied load in the range of 4 to 10 tonnes is required for practical purposes, although lighter loads may be used. The cone penetrometers are available with various capacities of cone resistance 100 MPa_ for investigations, while a range of 0 to 10 MPa can be ranging up to general purpose used where more sensitive investigations of soft clay are required. The cone resistance value provides a continuous measure of soil strength or density, and together with the friction ratio, provide very useful indications of the presence of narrow bands of geotechnically significant layers such as thin, soft clay layers or lenses of sand which might otherwise be missed using conventional drilling methods. The lithology of the encountered soils is interpreted from static cone data and is generally presented on the static cone log sheets. It is important to note that the lithology is interpreted information and is based on research by Schmertmann (1970), Sanglerat (1972), Robinson and Campinalli (1986), modified to suit local conditions as indicated by borehole information and laboratory testing. As soils generally change gradually it is sometimes difficult to accurately describe depths of strata changes, although greater accuracy is obtained with the static cone compared with conventional drilling. Jn addition, friction ratios decrease in accuracy with low cone resistance values, and in desiccated soils. As a result, some overlap and minor discrepancies may exist between static cone and nearby borehole information. Portable Dynamic Cone Penetrometers - Portable Dynamic Cone Penetrometer (DCP) tests are carried out by driving a rod into the ground with a falling weight hammer and measuring the blows for successive 100mm increments of penetration. NOTEREP.SAM SOIL SURVEYS ENGINEERING
Page 23
-4- The DCP comprises a Cone of 20 mm diameter with 30 degree taper attached to steel rods of smaller section. The cone end is driven with a 9 kg hammer falling 510 mm (AS. 1289 Test 6.3.2). initially for pavement subgrade investigations, and The test was developed empirical correlations of the test results with California Bearing Ratio have been published by various Road Authorities. The Company has developed their own correlations with Standard Penetration tests and Density Index tests in sands. LOGS The borehole or test pit logs presented herein are an engineering and/or geological interpretation of the subsurface conditions, and their reliability will depend to some extent on the frequency of sampling and the method of drilling or excavation. Ideally, continuous undisturbed sampling or core drilling will enable the most reliable assessment but is not always practicable or possible to justify on economic grounds. In any case, the boreholes or test pits represent only a very smalt sample of the total subsurface conditions. The attached explanatory notes define the terms and symbols used in preparation of the logs. interpretation of the information shown on the logs, and its application to design and construction, should therefore take into account the spacing of boreholes or test pits, the method of drilling or excavation, the frequency of sampling and testing and the possibility of other than “straight line" variations between the boreholes or test pits. Subsurface conditions between boreholes or test pits may vary significantly from conditions encountered at the borehole or test pit locations. GROUNDWATER Where groundwater levels are measured in boreholes, there are several potential problems. -Although groundwater may be present in lower permeability soils, it may enter the hole slowly or perhaps not at all during the time the hole is open. +A localized perched water table may lead to an erroneous indication of the true water table. -Water table levels will vary from time to time with seasons or recent weather changes and may not be the same at the time of construction. +The use of water or mud as a drilling fluid will mask any groundwater inflow. Water has to be bailed out of the bore and mud must be washed out of the hole or “reverted” if water observations are to be made. More reliable measurements can be made by use of standpipes which are read after stabilizing at periods ranging from several days to perhaps weeks for low permeability soils. Piezometers, sealed in a particular stratum, may be advisable in low permeability soils or where there may be interference from perched water tables or surface water. FILL The presence of fill materials can often be determined only by the inclusion of foreign objects (eg. bricks, steel, etc.) or by distinctly unusual colour, texture or fabric. also depend on investigation methods and frequency. Identification of the extent of fill materials will Where natural soils similar to those at the site are used for fill, it may be difficult with limited testing and sampling to reliably determine the extent of the fill. The presence of fill materials is usually regarded with caution as the possible variation in density, strength and material type is much greater than with natural soil deposits. Consequently, there is an increased risk of lf the volume and quality of fill is important to a project, adverse engineering characteristics or behaviour. then frequent test pit excavations are preferable to boreholes. LABORATORY TESTING Laboratory testing is normally carried out in accordance with Australian Standard 1289 "Methods of Testing Soi! for Engineering Purposes". Details of the test procedure used are given on the individual report forms and the attached explanatory notes summarize important aspects of the Laboratory Test Procedures adopted. ENGINEERING REPORTS Engineering reports are prepared by qualified personnel and are based on the information obtained and on current engineering standards of interpretation and analysis. Where the report has been prepared for the interpretation may not be relevant if the design a specific design proposal information and proposal is changed. If this happens, the Company will NOTEREP.SAM SOIL SURVEYS ENGINEERING
Page 24
-5- be pleased to review the report and the sufficiency of the investigation work. Every care is taken with the report as it relates to interpretation of subsurface conditions, discussion of geotechnical and recommendations aspects or suggestions for design and construction. Since the test sites in any exploration represent a very small proportion of the total site and since the exploration only identifies actual ground conditions at the test sites, even under the best circumstances actual conditions may vary from those inferred to exist. No responsibility is taken for:- * Unexpected variations in ground and/or groundwater conditions. *Changes in policy or interpretation of policy by statutory authorities. * The actions of other persons. «Any work where the company is not given the opportunity to supervise the construction using the Companies designs/recommendations. If differences occur, the Company will be pleased to assist with investigation or advice to resolve any problems occurring. SITE ANOMALIES In the event that conditions encountered on site during construction appear to vary from those expected from the information contained in the report, the Company Most problems are more readily resolved when conditions requests that it immediately be notified. are exposed than at some later stage, well after the event. REPRODUCTION OF INFORMATION FOR CONTRACTUAL PURPOSES Attention is drawn to the document "Guidelines for the Provision of Geotechnical Information in Tender Documents", published by the Institution of Engineers, Where investigation is provided for tendering purposes, it is Australia. information obtained from this recommended that all information, including the written report and discussion, be made available. In circumstances, where the discussion or comments section is not relevant to the contractual situation, it may be appropriate to prepare a specially edited document. The Company would be pleased to assist in this regard and/or to make additional report copies available for contract purposes at a nominal charge. REVIEW OF DESIGN Where major civil or structural developments are proposed or where only a limited investigation has been completed or where the geotechnical conditions/ constraints are quite complex, it is prudent to have a joint design review which involves a senior geotechnical engineer. We would be happy to assist in this regard as an extension of our investigation commission. SITE INSPECTION The Company will always be pleased to provide engineering inspection services for geotechnical aspects of work to which this report is related. i) Site visits during construction to confirm reported ground conditions ii) personnel in identifying various soil/rock types such as Site visits to assist the contractor or other site appropriate footing or pier founding depths, the stability of a filled or excavated slope; or iii) Fulltime engineering presence on site. In the vast majority of cases it is advantageous to the principal for the geotechnical engineer who wrote the investigation report to be involved in the construction stage of the project. NOTEREP.SAM SOIL SURVEYS ENGINEERING
Page 25
Soil Surveys Engineering Pty. Limited LEGEND SHEET ing Goon RECO No 195 AGN 054 049 631 ‘eral briebere® sokeurveya com au Lovol 2 19 Firchey Street Unt 930 Lawrence Rr 11 Production Ave ‘Oana Norang 4211 Kawene Walora G 4578 PO Sex 2011 PO Box 2 Qaat Budde 0 4573. Prt 7 5509 1528 Phen 7 5489 1733 Fex 8 7 5009 6560 Fex 81 7 5678 9616 Fax 61 7 5050 2037 Information ORILLING TYPES ¥ - open hole drilling using augers and a steel "V" bit TG - open hole drilling using augers and a Tungsten Carbide bit WEB - wash boring using a drag or blade bit CH - CLAY of high plasticity RR - wash boring using a rock roller bit NMLC - coring using a NMLC core barrel Casing - steel casing in hole Graphic Legend CI - CLAY of intermediate plasticity DEPTH wei Expressed in metres below the surface unless otherwise noted CL - CLAY of low plasticity ROCK DESCRIPTION MH - SILT of high plasticity Rock name, grain size, colour, texture, fabric and any other relevent comments s WEATHERING GRADES MI - SILT of intermediate plasticity XW - Extremety Weathered OW - Distinctly Weathered ML - SILT of low plasticity SW - Slightly Weathered FR - Fresh Pt- PEAT STRENGTH cs estimate of UCS) OH - Organic SILTS and CLAYS of high W- extremely weak <1.0 MPa plasticity ove em one Wy en eek peta MPa OL - Organic STLTS and CLAYS of low MS - medium strong 25 to 50 MPa SY Plasticity S - strong 50 to 100 MPa SAKA SC - Clayey SAND. VS - very strong 100 to 250 MPa SS? ES - extremely strong >250 MPa GS LY $M - Silty SAND CORING DETAILS ~ " Rec - core recovery in each run expressed as a % x : SP - poorly graded SAND RQD - Rock Quality Description expressed as a % Defect Description : SW - Well graded SAND 3.00m:;J45;p,s,0,z GC - Clayey GRAVEL Depth in mstres; Detect Type and angle with the core axis;planarity,roughness, aperture, infill | Defect Type Pianarity Roughness Aperture — Infill GM - Silty GRAVEL uJ - Joint p- Planar s-Smooth o- Gpen z-Clean é F - Follation s-Sub-planar_r- Rough ¢-Closed c- Clay GP - poorly graded GRAVEL 8 - Bedding c- Gurvilinear v-very Rough Q - Quara 4 ; ~ Vein u-Undutating |- Slickensides - ite § - Shear Zone 9 w - Weathered Rock GW -well graded GRAVEL T - Fault t- Limonite C- Clay Seam Fill Z- Contorted Zone Ru - Relict Joint Core loss Testing [ SPT SPT testing Meta-Sittstone Phyllite 10.15.15 Blows! 150mm or as noted ~— Meta-Sandstone Greywacke USO (50) USO Tube Samples (% Recovery} [ PP = 500 kPa Pocket penetrometer reading Tuff vs Vane Shear Testing g 1.30.5: 25 ‘Seating, peak and residual : Corrected vatue Sandstone DIST Disturbad Samples Siltstone Mudstone Conglomerate Water Intersections aor Water steady level por ‘Water first noted Basalt Testing Results La VOLCANIC ASH Corrected Point Load Test Result _— Is50=4 (A) A- Ade, D - Diametral 3 VOLCANIC AGGOLMERATE Breccia Granite MARINE DEPOSITS I ISSUE No. 1.1 08/10/97 RSOO5
Page 26
Project No. 307-2624 * August, 2007 APPENDIX A BOREHOLE RECORDS ZB SOIL SURVEYS ENGINEERING
Page 27
Soil Surveys Engineering Pty. Limited BOREHOLE RECORD SHEET
ee RPECQ No. 193
saetarerecy Soe MER 8 28 aren OF [ipoain ae Borehole Number : 1
i Beau = Renee, = SSE are .
Ree ORs, Project Number: = 307-2624
Project Name : Proposed House
Easting: Northing : RL: Location : 6 The Promontory, Noosa Waters
Logger: RH Driller: RH DrilingRig: Evini7s0 ‘Client: De Nova Group Pty. Ltd.
Date : 10/08/2007 Page : 1
Drilling Method 2 , DCP Test $
= i amples and
~ela]s|a]a] Deeth & Description & rows/100mm) Remarks
i - 0.12 FILL L Silty SAND (SM) Loose, fine to medium grained, Tp 5 =
- 0.30 grey. with oreanics, mo Pobot: > 4
= 0.60 ; : >
LE g nd dark brown, nist i D 4
1.0 NATURAL sat SAND (SM) Loose to medium dense, fing : —
- to medium grained, light grey, moist. : o 3
_ 1.40 ‘ ~ pb 7
— Silty SAND (SM) Med! di to dense, fine t ; - ~~
~ Leo ; median aie moist. sey line v0 ' Yo ° 3
r 2.0 , LL) Sitty SAND (SM) Dense to very dense, fine to medium ! » 4
— grained, light grey, moist, : fib ~y
F ire ;
rw 270 ! ° 7
= Silty SAND (SM) Medium dense, fine to medium ‘ op +
grained, light grey, wet. ' 1 —
1 - 3.40 ! 7
— {A Silty SAND (SM) Medium dense, fine to medium : —
— ‘A4/\ grained, dark grey and brown, wet, ‘ q
F 40 Uj 4
| E50 J
- 60 iy
—_ :
| - 6.70 KZ fot
m C/ 7) Silty SAND (SM) Dense to medium dense, fine to tot
- 7.0 /, medium grained, dark grey and brown, wet. tog
- 250. ‘hd : :
- Borehole 7.50m i |
{ a Terminated io
F 80 i
F_20 PE 4
C pbb od 4
FE 16.0 i i
COMMENTS
1) Groundwater noted at 2.7m. 2) DCP Refusal at 1.9m, SZ
Approved = +f
; Date : o aT
‘w Water First Noted ~7 Water Steady Level
ISSUE No. 1.1 080/97 RSOO7A
Page 28
Surveys Engineering Pty. Limited BOREHOLE RECORD SHEET
Gastectnioa engineers «= RPECG No, 195
MO taewa > sNPrgacin tee Borehole Number: 2
PO Box 2011
Pe, | Rare Project Number: 307-2624
Project Name : Proposed House
Easting : Northing RL: Location : 6 The Promontory, Noosa Waters
Logger: RH Diller: RH’ DrilingRig: EVe7so Client: De Nova Group Pty. Ltd.
Date : 10/08/2007 Page : 1
Drilling Method DCP Test
qi] Deeth Description (blows/100mm) Samples and
> iets) e § 10 15 20 25 Remarks = §
i SN Pavers, pos pot o -
- FILL SAND (SP) Loose, fine to coarse grained, light Peabo; bod > 7
— FILL Sandy GRAVEL (GP) Medium dense, fine to coarse hopobot D 4
- size, dark brown, fine to coarse grained sand, robo bt 4
C Oist : Pb D 4
P10 FILL Silty SAND (SM) Medium dense, fine to medium : bob 7
D /7\\erained, dark grey and brown, with low plasticity ' hore 5 q
a ° UW. NATURAL Silty SAND (SM) Loose to medium dense, Anam ==: > 4
E Ai//A Silty SAND (SM) Medium dense, fine to medium it > 4
- 20 ZA grained, dark grey, trace of organics, moist. ‘ D o
a GY D I
FE Mh i ° 3
- Ww 270 e y
- = Vi, ‘J Silty SAND (SM) Medium dense, fine to medium : D 4
3.0 “A grained, dark grey, trace of organics, wet. , 4 —
E30 meds
Zz Silty SAND (SM) Loose to medium dense, fine to pore gt
- 3.60 Z medium grained, dark grey, with low to medium rr
E 40 / Silty SAND (SM) Loose to medium dense, fine to Porogo oto
-—" 4.10 i, medium grained, light grey, wet. pobobo gt
E ZZ Silty SAND (SM) Medium dense, fine to medium Popo or
i - VW grained, dark grey and brown, wet. fog obo
F 50 VY on
r toy
E 6.0 600 Doig
é Borehole 6.00m Poboroi
t- Terminated iit a
E70 -
F fot
| E80 ii
p90 i
E 100 Pb if
COMMENTS
1) Groundwater noted at 2.7m. 2) DCP Refusal at 1.9m.
Approved + e S
Date : gO 1 F 1 O77
-w Water First Noted \ Water Steady Level
om: ISSUE No. 1.4 0810/97 RSCO7A
Page 29
Project No. 307-2624 * August, 2007 APPENDIX B LABORATORY TEST RESULTS #% SOIL SURVEYS ENGINEERING
Page 30
Soil & Water Laboratories P/L 16/39 Corperation Circuit, Tweed Heads, NSW. 2466. Phone: (02) 5823 4422: Fax: (07) 3603 9063 Reference Number: Certificate Number: Date Received: 1. Signed: Trevor Screening Test For Soll Surveys Engineering Pty Ltd, Unit 1, 25 Premier Circuit, Warana. Qld. 4575, Noosaville 307-2624 14 2624 200214 16/08/2007 Date Tested: 17/08/2007 Date Issued: 17/08/2007 pH (1:5susp.) Sample Number | Borehole/Location H20 for and on behalf of Soil and Water Laboratories P/ Nelson - Laboratory Manger - Acid Sulphate Soils and Waters Page: ‘Samples suppied by others 2. Samples tested in ‘as received’ condition 1of4
Page 31
pa Soil & Water Laboratories P/L
16/39 Corporation Circuit, Tweed Heads South, NSW. 2486
—~ Phone: (02) 5623 4422; Fax (07) 3603 9063
NATA
ct Reducible Sut ali A Acidity Test R
For Soil Surveys Engineering Pty Ltd, Unit 1, 25 Premier Circuit, Warana. Old. 4875, WORLO RECOGNISED
ACCREDITATION
Page: 10f1
This Document is issued in
accordance with NATA'S
accreditation requirements
Certificate Number:200220 Ref.Number, 14 ~- 2624
Nossaville Accredited for compliance with 1SO/
IEC 17025
Date: 27-Aug-07 Project Number, 307*-2624
Tests Completed: 21-Aug-07 Samples Received:
Signed: eh 09: Po
Trevor Nelson - Chemical Laboratory Manger:
17-Aug-07
for and on behalf of Soil and Water Laboratories P/L.
Determinations have been derived by the adoption of published test methods recommended by National Committea for Acid Sulphate Sails {NatCASS); Queensland Acid
1 Sulphate Soils Management Advisory Committee (QASSMAC); Queenstand Add Sulphate Soils Investigation Team (QASSIT) & Queensland Department of Natural
Resources, Mines and Energy; as described in the 'Acid Sulphate Soils Laboratory Methads Guidelines 2004".
2 Samples supptied by others
‘3 Samples tested in ‘as received’ condition
4 The resutts of the tests, calibrations and/or measurements incided in this doounent are traceable to Australiar/national standards
S NATA\Is a signatory to the APLAC mutual recognition arrangement for the mutual recognition of the equivatence of testing, calibration and inspection reports.
6 Denotation: n/a - not appiicable; n/r - nol required
Page 32
Soil & Water Laboratories P/L
16730 Corporation Carcut, Tweed Heads South, NSW. 2486
Phone: (02) 5623 4422; Fax: (07) 3503 9083
Calculated Factored Liming Rates
Basad on Certificate Number: 200220
Page: 1d
Reteronce Number, 4 + 2824
Date: 27-Aug-07 Client Order Project Number, 307°-2624
ay
ah oF
‘Siro. ‘or and on behalf of Soll ard Waler Labaratoriaa PAL
Trevor Nelson - Chemical Laboratory Manager
1 Determinations Assocatad wih the above quoted carficata cumber, hava bean dered by ihe adoption of published test methods recommentied Dy: Nations! Comrise for Aci! Sulphate Sos (NatCASS}: Quecnitand Acid Sulphate Sols Management Advisory Commitee (GASSMAC} Queensland Acid Suiphate Soila
Investigason Team {QASSIT) & Queansland Departmen of Natural Resources, Mines and Energy, 23 described wn the ‘Aca! Suiphala Soils Laboratory Mathods Guidelines 2004.
‘Samples supplied by others
‘Sampies lasted in ‘as recowed condition
The resuts of he tests, calbvations andi messurements associaled wth the above quoted certiicate number, aro tracaable to Auslralaninational standards
Lime dosing rates inchida a tacts of safely of 15.
100% punty (neuirakeng value) for aglme has been assumed; vanaton tom 100% in the product actually uted rust be lactored accontngly
‘Ady dansily of 45 tonnesim3 has been adopled for cakulalon of factored lang rates.
In determining ANC valves, pantcies mckdng shell greater Inen 2mm are exckided by sieving and vaible ford shel is removed by heed.
In datenining laring rales, the ANC values hava bean factored by 80%
10. The supemsing Scents Engineer shout! make thew own assessments regarding imng 6s, taking ta consiteraton ASSMP and Autnosty requrements
11 Tho Superwsing Scionts/Engneer should make their own essessmenis regaxiing lhe faclor of safety and dry densty valuss adopted for cakuistons
12 nt derolae ‘not requested’ 1va ‘not applcabis’
eereneaan
Page 33
Project No. 307-2624 * August, 2007 APPENDIX C BOREHOLE LAYOUT PLAN BY SOIL SURVEYS ENGINEERING
Page 34
earirinaary, Borehole Layout Plan 6 The Promontory, Noosa Waters Soil Surveys Engineering Pty Limited Project 307-2624 for DeNova Group Pty Lid Date August 2007
Used in these records
07/1586 - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.