HESSIAN 1 The designs, drawings and specification are copyright and always
BOUNDARY
50mm WIDE SIZE STAKES ANGLE CUT POST TOPS
REFER TO PLAN VIEW FOR remain the property of Blackburne Jackson Design Pty Ltd.
2200 CTRS MAX.
N 45 litre 50x50mm POST SIZINGS
27
2 Before commencing construction:
100mm DEEP MULCH AS SPECIFIED. -Verify all dimensions and levels.
STAKE AS 100 litre 75x75mm 15 TYPICAL
PLANT AS FORM SHALLOW DISH DRAIN TO 75 x 50mm F14 ACQ TREATED -Verify location and levels of all services on site.
SPECIFIED
SPECIFIED BASE OF PLANT TO ENSURE MULCH HARDWOOD RAIL
25
200 litre 100x100mm -Verify that floor levels and finished levels will enable connection to
IS NOT IN CONTACT WITH PLANT CLASS 2 H3. services.
W E STEM
3 Do not scale this drawing. When in doubt refer to Architects.
300mm TOPSOIL AS PER NOTES. ADD 100 x 25mm F14 ACQ
WATER CRYSTALS AND SLOW TREATED HWD FASCIA issue amendment log by date
RELEASE FERTILISER AS PER CLASS 2 H3 NAILED TO
TREE MANUFACTURERS SPECIFICATIONS. 75 x 50mm F14 ACQ HWD RAILS. A OPERATIONAL WORKS ISSUE KM 04-10-23
S REFER TO TABLE FOR STAKE SIZES. PALINGS/RAIL CLASS 2 H3 OVERLAPPED AT B OPERATIONAL WORKS ISSUE NQ 14-11-23
STAKES TO BE F14 HARDWOOD NON- CORNER POSTS AS SHOWN
TREATED STAKES FREE FROM KNOTS 150mm CULTIVATED SUB-SOIL C OPERATIONAL WORKS ISSUE NQ 05-12-23
& WARPS ETC. 19 D OPERATIONAL WORKS ISSUE NQ 19-12-23
100 x 25mm F14 ACQ
2200 CTRS MAX.
STAKES TO BE DRIVEN IN TO A 100 x 100mm F14 ACQ HWD END
HEIGHT TO ENSURE STAKE DOES NOT TREATED HARDWOOD FASCIA E OPERATIONAL WORKS ISSUE NQ 13-03-24
MULCH : CLASS 2 H3 NAILED TO POST. CLASS 1 H5 SEASONED
DAMAGE LOWER LATERAL LIMBS. F OPERATIONAL WORKS ISSUE NQ 19-03-24
STAKES TO BE CENTRALLY POINTED MULCH GARDENS TO A MIN DEPTH OF PALINGS AND RAIL
NOTES: & DRIVEN VERTICALLY INTO GROUND 100mm WITH HOOP PINE BARK (CHIP
OUTSIDE OF ROOTBALL, TO BE SIZE 10-25mm) FROM MATURE TREES, NEIGHBOURING SITE
LOCATED IN NE & SW CORNERS FREE FROM WOOD SILVERS. DO NOT PROPERTY 15 x 100mm H4 ACQ HWD PALINGS
ROOT BARRIER TO BE APPLIED
MOUND MULCH HARD UP AGAINST NAILED TO PALINGS/RAILS
UNLESS OTHERWISE SPECIFIED
PLANT STEMS. 15 x 100mm H4 ACQ HWD M10 CUPHEAD BOLTS.
PALINGS NAILED TO COUNTERSINK BOLT AS SHOWN.
INSTALL SOCKED AG-PIPE IN GRAVEL
50mm WIDE HESSIAN SECURED PALINGS/RAILS
SURROUND FOR DRAINAGE TO
PERIMETER OF BASE CONNECTED TO LOOSELY TO TREE & FIXED TO STAKE 75x100mm F14 ACQ HWD POST.
WITH FLATHEAD GALVANISED NAILS
DETAIL
STORMWATER AS REQUIRED CLASS 1 H5 SEASONED.
OR STAPLES HEIGHT OF HESSIAN TIE
TO BE ONE THIRD TO ONE HALF OF 02 NOTE: END POSTS TO BE
100X100mm.
DO NOT AUGER ROUND PLANTING OVERALL HEIGHT OF TREE SCALE 1:10
HOLES, HOLES TO BE SQUARE IN
-
SHRUB & GROUNDCOVER PLANTING IN GROUND
PROFILE TO AVOID ROOT GIRDLING 75 x 50mm F14 ACQ TREATED 100x25mm F14 ACQ TREATED HWD
MOUND MULCH AT EDGE OF PIT TO HARDWOOD RAIL FASCIA CLASS 2 H3 NAILED TO
COLLECT WATER TO FALL DOWN
CLASS 2 H3. PALINGS
EDGES OF TREE PIT
TUBESTOCK AS SPECIFIED
100
100mm MULCH AS SPECIFIED
PLAN VIEW (WITH CORNER)
100
LOCALISED LOWERING OF SOIL
WHERE PLANTING OCCURS TO 50
100
ENSURE WATER RUN OFF TO
PLANTING AREAS consultants:
ROOTBALL DEPTH
TREE PIT TO BE EXCAVATED TO
STRUCTURAL ENGINEER :
DEPTH OF ROOTBALL BACKFILLED JUTEMASTER TM PEGGED SECURELY [company name]
WITH FRIABLE IMPORTED TOPSOIL FENCE ON RETAINING WALL NOTES
VARIES
WITH 100 x 100mm CROSS CUT FOR PH : [number] [@email here]
(50%), MIXED WITH SITE SOIL (50%) PLANT FOOTINGS TO BE 20 MPa NO
MAX 2% ORGANIC CONTENT FIRMING - REFER CIVIL ENGINEERING DETAILS. CIVIL ENGINEER :
FINES CONCRETE - POSTS TO BE BOLTED TO RETAINING WALL POSTS, 100 x 75mm
PROGRESSIVELY [company name]
300 x 300 x 600mm WITH - RETAINING WALL POSTS TO BE 100 x 200mm PH : [number] [@email here]
125mm COARSE DRAINAGE - ALIGN 200mm WIDE FACE OF RETAINING WALL POST PARALLEL TO FACE OF HYDRAULIC ENGINEER :
LOCALISE TOPSOIL AROUND PLANTS GRAVEL UNDER RETAINING WALL TO ENSURE THAT FENCE POST IS FLUSH ON FRONT FACE [company name]
APPROX. 3x TIMES THE VOLUME OF
600
TO RETAINING WALL POST. PH : [number] [@email here]
ADD WATER CRYSTALS AND SLOW THE ROOT BALL.
RELEASE FERTILISER AS PER ELECTRICAL & MECHANICAL ENGINEER :
150
MANUFACTURERS SPECIFICATIONS. FENCE NOTES [company name]
PH : [number] [@email here]
- MAX HEIGHT OF FENCE TO BE 1800mm
- FENCE TO HAVE 3 RAILS, INTERMEDIATE RAIL TO BE CENTRED BETWEEN
TOP AND BOTTOM RAIL.
ENSURE EDGES OF PIT ARE POROUS. - FIXINGS TO BE HOT DIPPED GALVANISED UNLESS WITHIN 1KM OF THE
RIP CLAY SOILS IF REQUIRED 150mm CULTIVATED SUB-SOIL COAST WHERE FIXINGS SHALL BE 316 STAINLESS STEEL.
- WHERE FIXINGS ARE LIKELY TO SPLIT TIMBER, PRE-DRILL TO 80% OF FIXING
DIAMETER.
125
1200 x1200mm SQUARE HOLE - ALL EXPOSED EDGES OF TIMBER TO BE ARISED.
(Minimum 2x width of rootball) - TIMBER FINSHES AS SPECIFIED.
03 DETAIL - ALL WORK TO BE PERFORMED IN ACCORDANCE WITH RELEVANT
DETAIL
AUSTRALIAN STANDARDS.
01 -
BIORETENTION TUBESOCK PLANTING
SCALE 1:10
300
- CONTRACTOR TO BUTT JOIN RAILS WITH BATTEN SCREWS IF
RECOMMENDED TECHNIQUE IS DISMISSED WITH AGREEMENT BY
SCALE 1:10
-
TREE PLANTING IN GROUND SECTION ARCHITECT.
100 x 25 TIMBER EDGING TO BE FLUSH 07 DETAIL
PLANTING AS PER WITH TOP OF TURF AND MULCH AS SCALE 1:10
PLANTING PLAN PER LANDSCAPE SPECIFICATION
-
TIMBER PALING FENCE IN GROUND
NOTES
BOUNDARY
BOUNDARY
TURF OR GRAVEL AS PER NOTES ANGLE CUT POST TOPS
REFER TO PLAN VIEW FOR
POST SIZINGS
27
ANGLE CUT POST TOPS
75 x 50mm F14 ACQ TREATED REFER TO PLAN VIEW FOR
POST SIZINGS
27
HARDWOOD RAIL
25
CLASS 2 H3.
75 x 50mm F14 ACQ TREATED
HARDWOOD RAIL
25
100 x 25mm F14 ACQ CLASS 2 H3.
TREATED HWD FASCIA
COMPACT EARTH BEARING STRIP CLASS 2 H3 NAILED TO
UNDER GARDEN EDGE PALINGS/RAIL 100 x 25mm F14 ACQ
TREATED HWD FASCIA nom 50x50mm SHS
NEIGHBOURING POWDERCOATED
CLASS 2 H3 NAILED TO
BOUNDARY
PROPERTY ALUMINIUM
19 100 x 25mm F14 ACQ PALINGS/RAIL
04 DETAIL TREATED HARDWOOD FASCIA
CLASS 2 H3 NAILED TO
SITE
SUPPORT FRAME
SCALE 1:10 19
-
TIMBER EDGING PALINGS AND RAIL 100 x 25mm F14 ACQ
TREATED HARDWOOD FASCIA
NEIGHBOURING SITE CLASS 2 H3 NAILED TO
PROPERTY PALINGS AND RAIL
NOM. 40mm THICK 15 x 100mm H4 ACQ HWD 75 x 50mm F14 ACQ TREATED
STONE STEPPERS LIGHTLY COMPACTED
PALINGS NAILED TO HARDWOOD RAIL
DECOMPOSED GRANITE (DECO)
PALINGS/RAILS CLASS 2 H3.
BEDDING SAND LAYER SITE
GEOFABRIC/WEEDMAT LAYER 15 x 100mm H4 ACQ HWD
ROAD VERGE
BELOW ALL DECO PALINGS NAILED TO
PALINGS/RAILS
nom. 35x35mm
75 x 50mm F14 ACQ TREATED POWDERCOATED
HARDWOOD RAIL ALUMINIUM
OPERATIONAL WORKS
CLASS 2 H3. VERTICAL BATTENS @
NOM. 200 80mm CTRS
GALVANISED FIXING BRACKET
TO STRUCTURAL ENGINEER'S FILL POWDERCOATED NOT FOR CONSTRUCTION
SPECIFICATION ALUMINIUM
100
SUPPORT POSTS
05 DETAIL FIXED TO TOP OF
BLOCK WALL
CHECKED : ……...………………………………….
SCALE 1:10 50 50 300 50
-
PRECAST CONCRETE STEPPER
100
FIXING TO
STRUCTURAL
ENGINEER'S
100 x 25 TIMBER EDGING LIGHTLY COMPACTED NOM. 40mm THICK SPECIFICATION
A R CHIT E CT UR E | L A NDS CA P E | INT E R IOR | P ROJECT MA NA G E ME NT
DECOMPOSED GRANITE (DECO) STONE STEPPERS 50
37 Aerodrome Rd Maroochydore Qld
FILL TO CREATE P.O. Box 154 Cotton Tree QLD 4558 phone 07 5443 3200
LEVEL YARD email [email protected] fax 07 5443 4030
600
FOOTINGS TO BE 20 MPa NO project:
FINES CONCRETE
300 x 300 x 600mm WITH PROPOSED TOWNHOUSE DEVELOPMENT,
125mm COARSE DRAINAGE
GRAVEL UNDER 54 ELM ST. & 5 PEARL ST. COOROY
FILL
NOM. 200 client:
125
ALTUM
title:
LANDSCAPE DETAILS
north date: SEP 2023
drawn: BM
LINE OF CONCRETE SLAB
08 DETAIL 09 DETAIL 10 DETAIL checked: GC
SCALE 1:10 SCALE 1:10 SCALE 1:10
OF TERRACE OR BUILDING -
TIMBER PALING FENCE ON BLOCK WALL -
TIMBER PALING FENCE BESIDE BLOCK WALL -
ALUMINIUM SCREEN ON BLOCK WALL scale @ A1 : 1:10
WHERE APPLICABLE
scale @ A3 : 1:20
06 DETAIL project/drawing no. sheet: A1
7283_L07-01_F
SCALE 1:10
-
PRECAST CONCRETE STEPPER - PLAN
GSPublisherVersion 1452.0.59.0
7283-26-Cooroy.pln printed: Tuesday, 19 March 2024 9:38 am
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 3 - RFI Amended Landscaping.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.9 MB (small file)
- File type
No other editions are linked here.