Table 2-4: External catchment overland flow (entering site) and pipe flow (diverted around site via Pavilion St)
Flow 10% AEP 5% AEP 2% AEP 1% AEP 1% CC AEP
Area Flow Area Flow Area Flow Area Flow Area Flow
(ha) (m3/s) (ha) (m3/s) (ha) (m3/s) (ha) (m3/s) (ha) (m3/s)
TOTAL 1.960 0.437 1.960 0.534 1.960 0.671 1.960 0.768 1.960 0.982
EX2 Overland - - 0.300 0.097 0.618 0.234 0.782 0.331 1.032 0.545
Pipe 0.437 0.437 0.437 0.437 0.437
TOTAL 0.287 0.165 0.287 0.093 0.287 0.114 0.287 0.130 0.287 0.165
EX1 Overland - - 0.049 0.018 0.093 0.039 0.116 0.055 0.152 0.091
Pipe flow 0.075 0.075 0.075 0.075 0.075
Table 2-5: Summary of Developed Catchment Parameters
Sub-catchment Downstream Area (ha) Imperviousness (%)
Catchment
Ex2 SUB3 1.960 50
Ex1 SUB1 0.287 50
SUB3 SUB2 1.780 50
SUB1 SUB2 2.079 50
SUB2 SUB4 1.354 5
SUB4 SINK 0.819 5
Ex1 (<10% AEP) 0.0* -
Ex1 (5% AEP) 0.049* 50
Ex1 (2% AEP) 0.093* 50
Ex1 (1% AEP) 0.116* 50
Ex1 (1% AEP CC) 0.152* 50
Ex2 (<10% AEP) 0.0* -
Ex2 (5% AEP) 0.300* 50
Ex2 (2% AEP) 0.618* 50
Ex2 (1% AEP) 0.782* 50
Ex2 (1% AEP CC) 1.032* 50
* area factored based on flow rate for events greater than 10% AEP
The increased imperviousness and changes to catchment areas associated with the development resulted
in an increase in peak flows to the sites outlet as shown in Table 2-6. Mitigation will be required to ensure
non-worsening downstream and satisfy the lawful point of discharge requirements.
Table 2-6: Comparison of Peak Flows At Site Outlet (Existing Vs. Developed)
Event AEP 63.20% 50% 20% 10% 5% 2% 1% 1%CC
Existing (m3/s) 0.33 0.43 0.72 0.92 1.21 1.55 1.86 2.57
Developed (m3/s) 0.34 0.43 0.73 0.94 1.25 1.66 2.04 2.63
Change (m3/s) 0.01 0.00 0.01 0.02 0.04 0.11 0.18 0.06
23-0167SMP01-V3 | Stormwater Management Plan | 33 Pavilion Street, Pomona Page 22