Appendices 9,10,11,12 & 13 Email 4 of 4 - MCU16/0153 REC16/0041

of 48

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                SPECIFIC OUTCOMES                                         PROBABLE SOLUTIONS                        COMPLIANCE                   COMMENTS


O9 For Multiple housing Type 3 or 4, Visitor                                                                        ALTERNATIVE   The proposed development is located in the
accommodation Type 4 or the accommodation unit                                                                       SOLUTION     Open Space Recreation Zone and includes a
component of an Entertainment and dining business                                                                                 site cover of 39% and a total GFA of
Type 3 (hotel)—the maximum gross floor area is                                                                                    9232m².
equivalent to the maximum allowable population
density in persons multiplied by 40m2, provided that
Lots 75-77 on P9311 Heron Street, Peregian Beach,
have a maximum gross floor area of 1,200m2.

O10 For the Neighbourhood Centre Zone the
maximum plot ratio is as follows—
a) 0.8:1 for site areas up to and including 2000m2;
and
b) 0:3:1 for that area of a site in excess of 2,000m2.
Flooding and drainage
O11 Buildings and other works are designed and sited      S11.1 For new buildings or structures or additions of         YES       All buildings will include a finished floor
to—                                                       more than 50m2 gross floor area to an existing building                 level that is at a minimum 500m above the
a) provide flood free access to premises and flood free   or structure, floor levels for habitable rooms are—                     known flood level.
habitable areas;                                          a) for areas where minimum floor levels are available—
b) allow only minor, short term and infrequent            not less than the specified level;
flooding of non-habitable areas; ‘                        b) for areas where flood modelling is available—a
c) ensure carparking areas can be adequately drained;     minimum of 500mm above the modelled flood level;
d) ensure drainage does not adversely impact upon         and
other premises; and                                       c) for areas where flood modelling is not available, a
e) ensure filling or excavation does not adversely        minimum of 500mm above the highest known flood
impact upon other premises by—                            level;
i. causing ponding on the site or nearby land;            AND
ii. increasing flooding, which adversely affects the      S11.2 Where Council infrastructure is                         YES       Please refer to the Engineering Services
Log in to download the original file

Appendices 9,10,11,12 & 13 Email 4 of 4 - MCU16_0153 REC16_0041.pdf · 6.2 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.