Table 2: Details of Qualitative Risk Assessment for Property (AGS 2007
Assessed
Hazard Likelihood Consequence
Risk
Comments
The driveway alignment exploits an existing track in
some parts, and although the central portion of the
driveway is proposed sidelong to a moderately
steep slope; given the presence of stiff to very stiff
residual soils and XW materials from surface, no
1: Proposed driveway - evidence of existing instability (including relatively
shallow failure through existing good performance of existing fill embankments),
natural soil materials (fill Unlikely Minor Low apparent lack of shallow groundwater, and the
subgrades or earthworks cuts); proposed engineer designed retention of future fill
or future fill materials for the driveway, it is considered Unlikely that a
landslip would develop, subject to implementation of
the recommendations in Section 4 (e.g. foundations
levels and fill quality). Given a potential Medium
impact from such shallow instability the resultant risk
would be Low as per AGS 2007.
Given the presence of stiff residual soils at surface,
and stiff to very stiff XW materials below at shallow
depth, the rounded nature of the spur crest where
construction is proposed, and negligible catchment
2: Proposed residence on
for water above the site and apparent lack of
subdivided Lot - Failure
groundwater, and no evidence of existing instability
through natural soils or XW Unlikely Medium Low
in the vicinity of the proposed residence, it is
materials above the foundation
considered Unlikely that a landslip would develop,
depth
subject to implementation of the recommendations
in Section 4. With a potential Medium impact from
such shallow instability the resultant risk would be
Low as per AGS 2007.
The likelihood of a deep failure through the weathered
phyllite rock below the foundation depth is assessed
3: Proposed residence on
as Barely Credible due to the strength of these
subdivided Lot, or proposed
Barely materials, no evidence of existing instability, and
driveway alignment - Deep Major Very Low
Credible relatively consistent nature of the sloping ground
seated failure in weathered rock
across the development area. Although the
below the foundation depth
consequence of such a failure could be Major, the
resultant risk is Very Low as per AGS 2007.
The potential impacts on slope stability of the development components have been assessed, and the
measures recommended below in Section 4 have been designed to mitigate those impacts.
3.2.1 Effluent Disposal
Ground Drill has prepared an effluent disposal report (Ref. Job No. 20/373-2, dated 22 March 2021). The
indicative proposed effluent disposal area is located to the east of the proposed building area, as illustrated in
the Ground Drill report, which is attached at the end of this letter. This area is considered acceptable from a
slope stability point of view. Should the proposed effluent disposal area be moved, Tectonic must be notified
to re-assess the impacts on slope stability.
Ground Drill has recommended application rate of 3 mm/day using a covered surface irrigation system.
Considering this application rate compared with the trigger levels required for the occurrence of a landslide in
this setting (e.g. a severe rain event), the effect of the irrigation on slope stability would be considered
minimal. Nevertheless, it is recommended that the land application area be revegetated as soon as possible.
Vegetation should include native species which are used for stabilisation of steep slopes and suitable for wet
soils with high nutrient loads (e.g. Lomandra).
The on-site effluent disposal system must be located a suitable distance away from any watercourse,
dwellings and recreation areas. Setback distances are subject to the level of treatment proposed and shall
be in accordance with Local and State Government requirements.
9/14
Document Set ID: 21426326