Skip to the record
Trusted by locals. Built for Noosa.

Original source · versioned page text

Combined Approved Plans RAL21/0003

of 115

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (12.4 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
                Total Concept Homes                                                                             20332-001-Rev1
                                                                                                                 22 March 2021

                Table 3: Retaining Wall Design Parameters
                                                                                 Lateral earth pressure coefficients
                                          Unit       Friction
                  Retained material     weight        angle
                                                                           Ka                    Ko
                                        (kN/m3)     (Degrees)                                                          Kp
                                                                    (Cantilever wall)    (Non-yielding wall)


                  Stiff to Very Stiff
                                           18           26                0.39                  0.56                   2.56
                  Natural Clays


                  Weathered Phyllite
                                           21           35                0.27                  0.43                   3.69
                  Rock



                These parameters do not include allowance for surcharge above the wall, or additional loads imposed by
                sloping ground.
                Subsurface drainage must be installed behind any retaining walls in order to prevent the development of
                hydrostatic pressure (e.g. slotted ‘aggi’ pipe wrapped in filter ‘sock’ placed in gravel backfill).

                4.5     Drainage
                Adequate site drainage should be installed to ensure that stormwater runoff is directed away from the
                building walls and footings (e.g. swales in landscaped areas or grated drains across pavements up slope of
                structures including retaining walls for the driveway). Diversion drainage should be installed above the crest
                of all cut/fill batters, and toe of all cut batters. Uncontrolled flow of stormwater over embankment batters (e.g.
                from gutter overflow during high intensity storms, or if formal arrangements are not in place for the retaining
                wall on the neighbouring property to the south-west) has the potential to saturate and weaken the
                embankment materials, potentially leading to slumping failure. Future building and landscaping must be
                carried out to maintain good drainage.

                Subsurface drainage must be installed behind any retaining walls in order to prevent the development of
                hydrostatic pressure (e.g. slotted ‘aggi’ pipe wrapped in filter ‘sock’ placed in gravel backfill).

                All excess stormwater collected on site must be directed by pipes to the legal point of discharge, at least 5 m
                down slope from the proposed or existing structures. Surface dissipation, such as a rock weir or similar,
                must be installed at the stormwater outlet(s) to minimse the risk of soil erosion at the discharge point..
                Subsurface disposal of stormwater must not be undertaken.



                5.0       SUMMARY & CONCLUSIONS
                Based on the findings of our assessment we consider that there would be a Low Risk of slope instability
                impacting the proposed development. This advice is subject to implementation of the recommendations
                given in this report.




                                                                       13/14
Document Set ID: 21426326
Version: 1, Version Date: 24/03/2021
Log in to download the original file

Combined Approved Plans RAL21_0003.pdf · 12.4 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.