Attachment 1D - UNITS 6-7
Attached to the e-mail Development Application MCU - 226 David Low Way Peregian Beach Units 6-7(Email 6).
PEREGIAN BEACH VILLAS
UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
Sheet Index
Layout ID Layout Name Published
Sheet Index
A.01.1 COVER PAGE
A.01.2 GROUND FLOOR
A.01.3 FIRST FLOOR
A.01.4 ELEVATIONS
A.01.5 ELEVATIONS
NOTES
INSERT SKETCH RENDER
FOR CONSTRUCTION OF CONCRETE SLAB, FLOOR SYSTEMS, FRAMES & TRUSS'S PLEASE REFER TO HINTON STEEL FRAMES DRAWINGS
AREAS
GENERAL NOTES GROSS FLOOR AREA
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL UNIT 6: 56m2
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA. AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS. STANDARDS. UNIT 7: 56 m2
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND WITH THE B.C.A. REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
SCHEDULES OF FINISHES.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
DIMENSIONS TAKE PRECEDENCE OVER SCALE. AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND AS3788 & PART 3.72 OF THE BCA
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
Collins Developments
DIRECTLY TO THE SUPERINTENDENT. BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING HINTON STEEL FRAMES
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm 16 Computer Road Yatala
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS, THE ENTRY OF MOISTURE INTO THE BUILDING. AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL Gold Coast
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS. REQUIREMENTS qld australia 4207
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION telephone
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS. 3.8.1 OF THE B.C.A AND AS 3740 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET (617) 3287 3398
facsimilie
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER (617) 3382 7656
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS email: [email protected]
FOR MEMBER SIZES w w w .h i n t o n s t e e l f r a m e s .c o m .a u
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 4 pages
Page 2
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
4,905 250 4,905 WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
90 1,725 90 3,000 250 3,000 90 1,725 90
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
1,000
1,000
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
Patio Patio
2,500
2,500
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
1,360 140
1,360 140
2.5 x 4.9 2.5 x 4.9 THE ENTRY OF MOISTURE INTO THE BUILDING.
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
90
90
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
STANDARDS.
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
Ens Bed Bed Ens
3,300
3,300
2.5 x 1.5 3.3 x 3.0 3.3 x 3.0 2.5 x 1.5 SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
AS3788 & PART 3.72 OF THE BCA
WC WC
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
Bi-fold doors by 16W W16
AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
90
90
cabinet maker 15 15
REQUIREMENTS
14
T ROBE ROBE T
14
550
550
Laundry underneath 13 13
SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
staicase 12 12 AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
90
90
11 11 FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
10
UNIT 6 UNIT 7 10 FOR MEMBER SIZES
10,210
10,210
9 9
Bistro style blinds to
8 8 LEGEND
7 7
A/C AIR CONDITIONING AS SPEC. - INSTALLED
external staircase 6 6 BY CONTRACTOR
5 5 AP 450 X450 REMOVABLE ACCESS
Staircase open to 4 4 PANEL - LOCATION TO BE CONFIRMED ON SITE
external units 3 3 BL CONC. BLOCK WALL TO STRUCTURAL ENG.
2
Single Garage Single Garage 2 DETAIL - RENDER AND PAINT AS SPEC.
1 1 CF COLORBOND FLASHING TO DETAIL
6.0 x 3.0 6.0 x 3.0
6,000
6,000
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
DP 90mm DIA DOWNPIPE AS SPEC.
REFER TO DETAILS FOR TYPICAL FIXING
DRY CLOTHES DRYER
DW DISHWASHER
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
GUTTER BRACKETS @ MAX 900 CRS
EGL EXISTING GROUNDLINE
F REFRIGERATOR
FW FLOOR WASTE
GD S.S GRATED DRAIN AS SPEC.
90
90
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
780
780
HP HOT PLATES AS SPEC.
HWU HOT WATER
MR MECHANICAL RISER
780
780
MW MICROWAVE
NGL NATURAL GROUND LINE
90 1,725 90 3,000 250 3,000 90 1,725 90 OV OVEN
P PANTRY
PGL PROPOSED GROUNDLINE
4,905 250 4,905 PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
GROUND FLOOR
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.2 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 3
GENERAL NOTES
PEREGIAN BEACH VILLAS UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD,
CONTRACTOR TO CONFIRM ALL DIMENSIONS, LEVELS AND GENERAL
SITE CONDITIONS INCLUDING LOCATION OF EXISTING SERVICES ON
SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS.
DRAWINGS TO BE READ IN ASSOCIATION WITH SPECIFICATION AND
SCHEDULES OF FINISHES.
DIMENSIONS TAKE PRECEDENCE OVER SCALE.
DO NOT SCALE FROM DRAWINGS. REFER ANY DISCREPANCIES
DIRECTLY TO THE SUPERINTENDENT.
REFER TO STRUCTURAL ENGINEERS DRAWINGS FOR ALL FOOTINGS,
SLAB AND WALL DETAILS AND SIZING OF STRUCTURAL MEMBERS.
REFER TO SPECIFICATION FOR RELEVANT AUSTRALIAN STANDARDS.
5,315 250 5,315
PROTECTION FROM TERMITES IS TO BE INSTALLED IN ACCORDANCE
WITH AS3660.1-2000. AND PART 3.1.3 OF THE BCA.
90 2,835 90 2,300 250 2,300 90 1,445 90 1,300 90
STAIRS, HANDRAILS AND BALUSTRADES TO BE IN ACCORDANCE
WITH THE B.C.A.
ALUMINIUM WINDOWS TO BE IN ACCORDANCE WITH AS2047 AND
90
90
AS2048 AND CLEAR GLAZING IN ACCORDANCE WITH AS1288 AND
AS2208 AND THE DESIGN CONDITIONS AS NOMINATED.
90
90
BUILDER IS RESPONSIBLE FOR WATERTIGHTNESS OF THE BUILDING
AND MUST PROVIDE FLASHING, SARKING REQUIRED TO PREVENT
THE ENTRY OF MOISTURE INTO THE BUILDING.
3,585
3,495
Outdoor Living Outdoor Living WATERPROOFING TO WET AREAS IN ACCORDANCE WITH SECTION
3.8.1 OF THE B.C.A AND AS 3740
4.8 x 2.5 4.8 x 2.5
ALL BUILDING WORK SHALL COMPLY WITH THE BCA, LOCAL
AUTHORITY REGULATIONS & ALL RELEVANT AUSTRALIAN
STANDARDS.
REFER LANDSCAPE ARCHITECT PLANS FOR LANDSCAPE WORKS
90
90
SMOKE ALARMS ARE TO BE HARDWIRED AND IN ACCORDANCE WITH
AS3788 & PART 3.72 OF THE BCA
8,580
8,580
Living Living
CONCEAL ALL VENT PIPES AND WASTE PIPES WITHIN WALL FRAMING
4.8 x 2.4 4.8 x 2.4
MAX BUILDING HT ABOVE NATURAL GROUND LINE IS TO BE 8500 mm
Bay Window
Bay Window
16 16 AND IN ACCORDANCE WITH BBC DEVELOPMENT APPROVAL
REQUIREMENTS
4,486
4,486
15 15
12,640
14 14
12,800
13 13 SET DOWN FLOOR JOISTS TO ALL UPPER LEVEL BATHROOMS / WET
12 12
AREAS FOR FLUSH FLOOR FINISH BETWEEN POLISHED TIMBER
11 11
FLOORS AND TILED FLOORS - REFER STRUCTURAL ENG DRAWINGS
FOR MEMBER SIZES
10 10
Kitchen Kitchen
9
8 2.8 x 3.0 2.8 x 3.0
9
8
LEGEND
7 7 A/C AIR CONDITIONING AS SPEC. - INSTALLED
90
90
6 6
BY CONTRACTOR
AP 450 X450 REMOVABLE ACCESS
510
510
5 5
4 4
PANEL - LOCATION TO BE CONFIRMED ON SITE
BL CONC. BLOCK WALL TO STRUCTURAL ENG.
90
90
90
90
3 3
DETAIL - RENDER AND PAINT AS SPEC.
2 2
CF COLORBOND FLASHING TO DETAIL
1 1
CJ CLADDING CONTROL JOINT - REFER ELEVATIONS
CONC CONCRETE SLAB TO ENG. DETAIL
CPD CUPBOARD
Study Study DP 90mm DIA DOWNPIPE AS SPEC.
3,000
3,000
3.7 x 3 3.7 x 3 REFER TO DETAILS FOR TYPICAL FIXING
DRY CLOTHES DRYER
DW DISHWASHER
EG COLORBOND EAVES GUTTER TO PROFILE SHOWN WITH
WC
WC
GUTTER BRACKETS @ MAX 900 CRS
EGL EXISTING GROUNDLINE
F REFRIGERATOR
90
90
FW FLOOR WASTE
Balcony Balcony GD S.S GRATED DRAIN AS SPEC.
HC HOSE COCK - REFER FLOOR PLANS FOR LOCATION
HP HOT PLATES AS SPEC.
930
930
HWU HOT WATER
MR MECHANICAL RISER
MW MICROWAVE
250 NGL NATURAL GROUND LINE
500 90 3,670 90 965 965 90 3,670 90 500 OV OVEN
P PANTRY
PGL PROPOSED GROUNDLINE
4,815 250 4,815 PTF POLISHED TIMBER FLOOR AS SPEC.
RHS RHS TO STRUCTURAL. ENG. DETAIL
RV "WIRILY BIRD" OR SIM. APPROVED
S SINK
SD HARDWIRED SMOKE DETECTOR TO
COMPLY WITH A.S. 3786-1993
SHR SHOWER TO DETAIL
SHS SHS TO STRUCTURAL. ENG. DETAIL
SL SKYLIGHT AS SPEC.
T TUB
T-1 INTERNAL TILE AS SPEC.
T-2 EXTERNAL TILE AS SPEC.
TD HWD TIMBER DECKING AS SPEC.
TOW TOP OF WALL
VAC IN-BUILT VACUUM SYSTEM AS SPEC.
VB VANITY BASIN
WC TOILET SUITE
WF COLORBOND WALL FLASHING
WM WASHING MACHINE
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
FIRST FLOOR
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.3 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 4
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
Roof sheets @ 140 pitch fixed in ALY ALYSNITE FLAT SHEETING
BLK BLOCKWORK
accordance with manufactures FL CN CONCRETE
specification Roof sheets @ 120 pitch fixed DP1 90Ø DOWNPIPE
in accordance with EG1 EAVES GUTTER
MRS FC FIBRE CEMENT WITH 10mm EXPRESSED
manufactures specification
MRS JOINTS
Bay window, with specified cladding fixed EG1 FCC COMPRESSED FIBRE CEMENT
in accordance with manufactures FL FLASHING
Ceiling Level specification Ceiling Level LVF FIXED ALUMINIUM LOUVRE
EG1 FL MRS METAL ROOF SHEETING
FL ZINC ZINC CLADDING WITH STANDING SEAM
Aluminium framed windows NGL NATURAL GROUND LINE
fixed to manufactures PLY PLYWOOD WITH 10mm EXPRESSED
specifications
2,740
2,740
JOINTS
Timber ballustrade, in accordance with the SPR SPREADER
BCA and relevant Aus Standards SPT SPITTER
Floor Level
Timber screen Floor Level
Ceiling Level Ceiling Level
Steel post in accordance with engineers
specifications
Aluminium screen, in
2,740
2,740
accordance with manufacteres
Specified cladding fixed in accordance with specifications
manufactures specification
Slab Level NGL NGL Slab Level
1 Left Elevation 1:100
Roof sheets @ 140 pitch fixed
MRS MRS
in accordance with
manufactures specification
Ceiling Level Ceiling Level
EG1 EG1
Bay window with specified horizontal
cladding fixed in accordance with
manufactures specification
Timber ballustrade, in
2,740
2,740
accordance with the BCA and Aluminium framed bifold windows beyond
relevant Aus Standards fixed to manufactures specifications
Floor Level Floor Level
Ceiling Level Ceiling Level
Specified vertical cladding fixed in
accordance with manufactures
Fire rated wall in accordance specification
with manufacturers
2,740
2,740
specifications
Steel post in accordance with engineers
specifications
Slab Level NGL NGL Slab Level
2 Rear Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100, 1:353.41 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.4 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES
Page 5
ELEVATION LEGEND
PEREGIAN BEACH VILLAS UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, D-0
WD-0
DOOR NUMBER
WINDOW NUMBER
CF CLADDING FINISH
ABBREVIATIONS
AC AIR-CONDITIONING
ALY ALYSNITE FLAT SHEETING
0
Roof sheets @ 14 pitch fixed in BLK BLOCKWORK
accordance with manufactures CN CONCRETE
FL DP1 90Ø DOWNPIPE
specification
Roof sheets @ 70 pitch fixed EG1 EAVES GUTTER
in accordance with FC FIBRE CEMENT WITH 10mm EXPRESSED
manufactures specification MRS JOINTS
MRS FCC COMPRESSED FIBRE CEMENT
Bay window, with specified cladding fixed FL FLASHING
in accordance with manufactures LVF FIXED ALUMINIUM LOUVRE
EG1 MRS METAL ROOF SHEETING
Ceiling Level specification Ceiling Level
ZINC ZINC CLADDING WITH STANDING SEAM
FL NGL NATURAL GROUND LINE
PLY PLYWOOD WITH 10mm EXPRESSED
Aluminium framed windows JOINTS
fixed to manufactures SPR SPREADER
2,740
2,740
specifications Timber ballustrade, in accordance with the SPT SPITTER
BCA and relevant Aus Standards
Timber screen
Floor Level Floor Level
Ceiling Level Ceiling Level
Steel post in accordance with engineers
specifications
Aluminium screen, in
2,740
2,740
accordance with manufacteres
specifications Specified cladding fixed in accordance with
manufactures specification
Slab Level NGL NGL Slab Level
3 Right 1 Elevation 1:100
Specified vertical cladding
Aluminium framed windows
fixed to manufactures
Roof sheets @ 70 pitch fixed specifications
in accordance with MRS
manufactures specification
Ceiling Level Ceiling Level
EG1
Exposed rafters to roof system
Fire rated wall in accordance Specified vertical cladding
with manufacturers
2,740
2,740
specifications
Glass ballustrade, in
Timber screen accordance with BCA and Aus
Floor Level standards Floor Level
Ceiling Level Ceiling Level
Specified cladding
Aluminium screen, in
accordance with manufacteres
2,740
2,740
specifications
21 - 24 roller door
Slab Level NGL NGL Slab Level
4 Front Elevation 1:100
Amendments Wind Rating Checked By: Status: PR Date: 22-01-14
PEREGIAN BEACH VILLAS
A 06.12.13 Preliminary Client Approval CT Scale: 1:100 @ A3 Drawn by: CT
Client Signiture Approval:
C 11.12.13 Revised site plan + amendments CT Client Initials:
TBC
ALEX CHARLWOOD Drawing Title:
D 16-01-14 Amend GFA CT Date:
UNITS 6-7 , 226 DAVID LOW WAY, PEREGIAN BEACH, SUNSHINE COAST, QLD, E 22-01-14 Client request amendments CT
PH: 0410 650 745
ELEVATIONS
BSB No.: 1043429
NOTES: ABN: 59 980 573 352 Client: Drawing No.:
PR Drawings by HINTON STEEL FRAME QLD PTY LTD. ECO REMOTE A.01.5 E
ALL PLANS ARE COPYRIGHT AND MAY NOT BE REPRODUCED IN WHOLE OR AND PART WITHOUT WRITTEN PERMISION FROM HINTON STEEL FRAMES