DRAWING SIZE — At
HEIGHT DATUM
LOT 159 ON RP 48112
Level Origin PSM 99159 ye
Elanda St, Sunshine Beach 4
Survey information provided by “a
ARNOLD DEVELOPMENT CONSULTANTS
LEGEND
+\89 EXISTING SURFACE SPOT LEVELS.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
— sw/Ex ————_ INDICATES STORMWATER DRAIN EXISTING
AS NOTED
www.dialbeforeyoudig.com.au
SAY DIAL 1100
yy BEFORE YOU DIG
Level Datum AHD ,
y. ° >
8 BULONG 777
le “10 BE peMOUSHED 46
ge
Saal
ves
| ~FFL: 52.2
CLL)
Ce LLil LLL LLL
51.
51.71 ©
401010/0/8,0/0/0/0/0/6/6
SITE PLAN — SITE SURVEY & EXISTING SERVICES
Scale 1: 100
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
51.20 —
[eer
2 '6P
»
7
OS
Lor
KE
EX. SWPT EXISTING STORMWATER PIT
EX. SMH
EX. SCP
E.0.B.
K&Cc
NS.L.
FH.
TP
EP.
KERB
RCEW
SV
W.M
EXISTING SEWER MANHOLE
EXISTING SEWER CONNECTION POINT
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL PILLAR
EXISTING KERBING
REINFORCED CONCRETE END WALL
STOP VALVE
WATER METER
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
Revision | Description Date
“FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 299
a Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
Title:
SITE SURVEY & EXISTING
SERVICES
Project
36 ELANDA ST,
SUNSHINE BEACH
Date:
Drawn
TH
Design
TH
Checked:
RPEQ 5835
23
° S Richardson =
Drg No.
33082 -OW1.1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
LATE Appendix B - Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.