LATE Appendix B - Engineering Plans · MCU22/0139
Plans and drawings: the text below has words only, no drawings.
A 160
RD 100 WIDE x 100 DEEP 450x450 RP48112
CP
S FO N GRATED TRENCH SL. 51.60 FOR CONTINUATION, FOR CONTINUATION,
ING ATIO
BUP5180 DRAIN AROUND POOL REFER TO SITE
IL. 51.10 REFER TO BASEMENT
R AW PLIC PERIMETER
STORMWATER PLAN
adjacent 1 STORMWATER PLAN
D AP storey ON SHEET C1.00.
ON SHEET C2.00.
house
50 49.8 49.5 49
[email protected]%
[email protected]%
DP [email protected]%
TV/fire
RWO DP
DP [email protected]% RWO
living ens bed 2
deck court
[email protected]%
balcony driveway
kitchen coat DP robe
[email protected]%
hall
DP
+11,580 entry
RWO DOWN UP 15
7
6
5
4
3
2
1
DP
1
[email protected]%
pwr
DOWN
CP
[email protected]%
bbq
ELANDA STREET
pool garden
BUP9902 PO
10
12
13
14
11
RWO
2
3
5
7
4
6
8
9
12.5x2.5m lift 122.90 m 2
ELANDA ST
4
2
5
3
6
8
7
9
10
13
14
12
11
bbq pwr
UP
1 DP
14
10
12
13
11
DOWN
RWO
8
9
15UP
DP NGL+10,790 entry
hall
[email protected]%
[email protected]%
DP robe DP
coat
kitchen DP
living balcony
deck court
ens bed 2 PO
RWT 2 RWT 1 RWO RWO
DP [email protected]%
OSD
DP
[email protected]%
[email protected]%
[email protected]%
CP
PROPOSED 2 x 3000L 100 WIDE x 100 DEEP
SP307677
RAINWATER TANKS AND GRATED TRENCH
450x450 3000L OSD TANK LOCATED DRAIN TO
135 adjacent 2
SL. 51.60 COURT-HALL ENTRY
RP48112 ON BASEMENT LEVEL BELOW storey
IL. 51.10
house
GROUND FLOOR STORMWATER DRAINAGE PLAN
SCALE 1:100
LEGEND
A
RD
DP Ø100 DOWNPIPE
SP SPREADER PIPE
S FO N
IO INSPECTION OPENING
ING ATIO
AW PLIC
STORMWATER DRAINAGE NOTES:
Ø100 UPVC PIPE AS INDICATED
SITE AREA: 568.94m2 R
D AP
DENOTES DIRECTION OF PIPE FLOW
DENOTES OVERLAND FLOW PATH SITE DISCHARGE (MINOR STORM - 20% AEP):
PRE DEVELOPMENT: 16L/s
POST DEVELOPMENT: 14L/s
SITE DISCHARGE (MAJOR STORM - 1% AEP):
PRE DEVELOPMENT: 29L/s
POST DEVELOPMENT: 22L/s
A FOR D.A.. SUBMISSION 02/05/23
RAINWATER TANK 1 VOLUME: 3.0m3
RAINWATER TANK 2 VOLUME: 3.0m3
OSD VOLUME: 3.0m3
N. KOLOFF & ASSOCIATES
CIVIL & STRUCTURAL ENGINEERS
A.B.N. 15 657 583 235
POSTAL ADDRESS: PHONE: (02) 9560 0064
P.O. BOX 99, ANNANDALE FAX: (02) 9560 0065
NSW 2038, AUSTRALIA [email protected] MOBILE: 0417 485 481
DESCRIPTION OF WORKS AT : INDEX 1018A/2021
Nikolai Koloff
SHEET C3.00 B
PROPOSED NEW DUPEX
APPROVED BY:................................
NO. 36 ELAND STREET N. Koloff - Structural Engineer
SUNSHINE BEACH QLD 4567 B.E. (Hon.), L.G.E. M.I.E. AUST,. M.Eng. C.P. Eng.
Registration No.616868 NER
GROUND FLOOR STORMWATER DATE : 02/05/2023
GSEducationalVersion DRAINAGE PLAN
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
LATE Appendix B - Engineering Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.