Log in to see the plans as drawn CONCRETE WALL (PAINT COLORBOND ROOFING P.V. SOLAR PANELS GLASS BALUSTRADE CURTAIN WALL GLAZING P.V. SOLAR PANELS CONCRETE WALL (PAINT GLASS BALUSTRADE TOP OF LIFT OVERRUN
TOP OF LIFT
GREY) GREY) (MAX HEIGHT 11300m ABOVE GROUND)
1100
ROOF
RL +16000 mm
3400
LEVEL 2
RL +12600 mm
10200
3600
LEVEL 1
RL +9000 mm WHITE LIME STONE TILE
3200
GROUND FLOOR
BATTEN WALL FOR FUTURE TIMBER SOFFIT TO THE WHITE LIMESTONE TILE RL +5800 mm
ENTRY INTO BASEMENT CARPARK SANDSTONE TILES WHITE LIMESTONE TILE DOORS TO ENTRY SIGNAGE GREENWALL SANDSTONE TILES
GROWER PLANTS FINISH
FINISH BATTEN WALL FOR FUTURE UNDERSIDE OF ALL BALCONIES
1 ELEVATION - EAST GROWER PLANTS
DA-21.10 1 : 200
SANDSTONE TILE
DOWNLIGHTING TO WHITE LIMESTONE TILE P.V. SOLAR PANELS TOP OF LIFT OVERRUN
TOP OF LIFT
PORTE COCHERE FINISH (MAX HEIGHT 11300m ABOVE GROUND)
1100
ROOF
RL +16000 mm
3400
LEVEL 2
RL +12600 mm
10200
3600
LEVEL 1
RL +9000 mm
3200
GROUND FLOOR
BRONZE PAINT TO MULLIONS
FIRE HYDRANT BOOSTER PERIMETER BOLLARD TRANSFORMER PRECAST CONCRETE RL +5800 mm
NAVIGATION LIGHTING TO PANEL WALL ALONG
2 ELEVATION - NORTH PERIMETER OF DRIVEWAY BOUNDARY LINE
DA-21.10 1 : 200
POWDERCOATED COLORBOND ROOFING CURTAIN WALL GLAZING P.V. SOLAR PANELS POWDERCOATED TOP OF LIFT OVERRUN
P.V. SOLAR PANELS
TOP OF LIFT
ALUMINIUM SUN SHADE ALUMINIUM SUN SHADE (MAX HEIGHT 11300m ABOVE GROUND) GREY PAINT TO CONCRETE WALL
1100
ROOF
RL +16000 mm
3400
LEVEL 2
RL +12600 mm
10200
3600
LEVEL 1
RL +9000 mm
3200
GROUND FLOOR
PRECAST CONCRETE RL +5800 mm
PANEL WALL ALONG
BOUNDARY LINE TIMBER SOFFIT TO UNDERSIDE OF BALCONY
3 ELEVATION - WEST
DA-21.10 1 : 200
P.V. SOLAR PANELS BATTEN SCREENING WITH SIGNAGE TOP OF LIFT OVERRUN
TOP OF LIFT
(MAX HEIGHT 11300m ABOVE GROUND)
1100
ROOF
RL +16000 mm BLUE TINT GLAZING TO FOYER GLASS
3400
LEVEL 2
RL +12600 mm
10200
3600
LEVEL 1
RL +9000 mm
3200
GROUND FLOOR
RL +5800 mm
PRECAST CONCRETE
4 ELEVATION - SOUTH PANEL WALL ALONG
BOUNDARY LINE
DA-21.10 1 : 200
GREY TINT TO GLAZING
20 m
0 2 4 6 10
HOFMANN DRIVE MEDICAL CENTRE © Copyright Thomson Adsett Pty Ltd.
ABN 76 105 314 654
ELEVATIONS
Dimensions take precedence over Telephone +61 7 3840 9999
HOFMANN DRIVE, NOOSAVILLE QLD scaling. Do not measure off drawings [email protected]
as print sizes may vary 128 Robertson Street 1 : 200 @ A1 Rev.9
Fortitude Valley DA ISSUE
Qld 4006 Australia
RIBARJA PROPERTY TA # 18.0048.17 thomsonadsett.com DA-30.10 08.02.2019